Makita LD050P LD050P Instruction Manual

Makita LD050P Manual

Makita LD050P manual content summary:

  • Makita LD050P | LD050P Instruction Manual - Page 1
    Codes 10 Care 10 Safety Instructions 10 Areas of responsibility 10 Permitted use 11 Prohibited use 11 Hazards in use 11 en Limits of use 11 Disposal 11 Electromagnetic Compatibility (EMC 11 FCC statement (applicable in U.S 12 Laser classification 12 Labelling 12 Makita LD050P 1
  • Makita LD050P | LD050P Instruction Manual - Page 2
    instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users On / Measure Area / Volume / Pythagoras/ Memory Clear / Off 2 Makita LD050P Add / Subtract Measuring reference / Unit
  • Makita LD050P | LD050P Instruction Manual - Page 3
    Set-up Display Battery Area / Volume Measuring reference Info Min/Max Measuring Addition / Subtraction Pythagoras Memory Insert batteries -+ +- en To ensure a reliable use, do not i use zinc-carbon batteries. Change batteries when battery symbol is flashing. Units Main line Makita LD050P 3
  • Makita LD050P | LD050P Instruction Manual - Page 4
    in section "Message Codes". Example: Distance is measured from the front of the device. Distance unit setting 2 sec Switch between the following units: 0.000m 0.00m 0.00ft 0'00'' 1/16 0.00in 0 1/16in 4 Distance is measured from the rear of the device (standard setting). Makita LD050P
  • Makita LD050P | LD050P Instruction Manual - Page 5
    Aim active laser at target. The last value measured is displayed. 8.532 m Add / Subtract 1x 1 2 2x 3 7.332 m The next measurement is added to the previous one. The next measurement is subtracted from the previous one. 5.515 m 12.847 m Makita LD050P en Target surfaces: Measuring errors can
  • Makita LD050P | LD050P Instruction Manual - Page 6
    result is 7 i shown in the main line and the measured value above. 78.694 m3 6 The result is shown in the main line and the measured 4 5 i value above. Aim laser at second target point. 24.352 m2 4 5 Aim laser at second target point. 6 Aim laser at third target point. Makita LD050P
  • Makita LD050P | LD050P Instruction Manual - Page 7
    6 Aim laser at upper point. Aim laser at rectangular point. Aim laser at lower point. 7 8.294 m The result is shown in the main line and the measured distance i above. Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maximum measurement. Makita LD050P 7
  • Makita LD050P | LD050P Instruction Manual - Page 8
    en Measuring Functions Memory (5 last results) 5x 1 2 5 5 last results are displayed. 8.294 m 5 Navigates trough 8.294 m 5 last results. 8 Makita LD050P
  • Makita LD050P | LD050P Instruction Manual - Page 9
    may deteriorate by 0.15 mm/m for distances between 10 m to 30 m and by 0.20 mm/m for distances above 30 m. Functions Distance measuring Min/Max measuring Permanent measuring Addition/Subtraction Area Volume Pythagoras Memory en yes yes yes yes yes yes 2-point, 3-point 5 results Makita LD050P 9
  • Makita LD050P | LD050P Instruction Manual - Page 10
    range Correct range. 260 Laser beam inter- Repeat measurement. rupted Care Safety Instructions • Clean the device with a damp, soft cloth. The person responsible for the instrument • Never immerse the device in water. must ensure that all users understand • Never use aggressive cleaning
  • Makita LD050P | LD050P Instruction Manual - Page 11
    Measuring distances • Tilt measurement ƽ WARNING ƽ CAUTION Prohibited use Watch out for erroneous measurements if Flat batteries must not be disposed of with • • • • ƽ • • • ƽ • Using the product without instruction interference in other devices cannot be totally excluded. Makita LD050P 11
  • Makita LD050P | LD050P Instruction Manual - Page 12
    and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or ® LD050P Makita xxxxxxx xxxxxxx xxxxxxx Made in Hungary Batteries: 2 x AAA Complies with 21CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50,
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Makita LD050P
1
en
Table of Contents
Instrument Set-up
- - - - - - - - - - - - - - - - - - - - - - -2
Introduction- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2
Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2
Display- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3
Insert batteries - - - - - - - - - - - - - - - - - - - - - - - - - - - -3
Operations
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4
Switching ON/OFF - - - - - - - - - - - - - - - - - - - - - - - - -4
Clear - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4
Message Codes - - - - - - - - - - - - - - - - - - - - - - - - - - -4
Adjusting measuring reference - - - - - - - - - - - - - - - - - 4
Distance unit setting - - - - - - - - - - - - - - - - - - - - - - - -4
Measuring Functions
- - - - - - - - - - - - - - - - - - -5
Measuring single distance - - - - - - - - - - - - - - - - - - - -5
Permament measuring- - - - - - - - - - - - - - - - - - - - - - -5
Add / Subtract- - - - - - - - - - - - - - - - - - - - - - - - - - - - -5
Area- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -6
Volume- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -6
Pythagoras (2-point) - - - - - - - - - - - - - - - - - - - - - - - -7
Pythagoras (3-point) - - - - - - - - - - - - - - - - - - - - - - - -7
Memory (5 last results) - - - - - - - - - - - - - - - - - - - - - -8
Technical Data
- - - - - - - - - - - - - - - - - - - - - - - - - -9
Message Codes
- - - - - - - - - - - - - - - - - - - - - - - - 10
Care
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
Safety Instructions
- - - - - - - - - - - - - - - - - - - - - 10
Areas of responsibility - - - - - - - - - - - - - - - - - - - - - - 10
Permitted use - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11
Prohibited use- - - - - - - - - - - - - - - - - - - - - - - - - - - - 11
Hazards in use - - - - - - - - - - - - - - - - - - - - - - - - - - -11
Limits of use - - - - - - - - - - - - - - - - - - - - - - - - - - - - -11
Disposal - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -11
Electromagnetic Compatibility (EMC)- - - - - - - - - - - -11
FCC statement (applicable in U.S.) - - - - - - - - - - - - -12
Laser classification- - - - - - - - - - - - - - - - - - - - - - - - -12
Labelling - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -12