en Message Codes If the message Error does not disappear after switching on the device repeatedly, contact the dealer. If the message InFo appears with a number, press the Clear button and observe the following instructions: No. Cause Correction 204 Calculation error Perform measurement again. 252 Temperature too high Let device cool down. 253 Temperature too low Warm device up. 255 Received signal too Change target surface weak, measuring (e.g. white paper). time too long 256 Received signal too Change target surface high (e.g. white paper). 257 Too much background light Shadow target area. 258 Measurement outside of measuring range Correct range. 260 Laser beam inter- Repeat measurement. rupted Care Safety Instructions • Clean the device with a damp, soft cloth. The person responsible for the instrument • Never immerse the device in water. must ensure that all users understand • Never use aggressive cleaning agents these directions and adhere to them. or solvents. Areas of responsibility Responsibilities of the manufacturer of the original equipment: Makita Corporation Anjo, Aichi 446-8502 Japan / Makita, Jan-Baptist Vinkstraat 2, 3070, Belgium Internet: www.makita.com The company above is responsible for supplying the product, including the User Manual in a completely safe condition. The company above is not responsible for third party accessories. Responsibilities of the person in charge of the instrument: • To understand the safety instructions on the product and the instructions in the User Manual. • To be familiar with local safety regulations relating to accident prevention. • Always prevent access to the product by unauthorised personnel. 10 Makita LD050P

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Makita LD050P
10
en
Message Codes
If the message
Error
does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message
InFo
appears with a
number, press the Clear button and
observe the following instructions:
Care
Clean the device with a damp, soft cloth.
Never immerse the device in water.
Never use aggressive cleaning agents
or solvents.
Safety Instructions
The person responsible for the instrument
must ensure that all users understand
these directions and adhere to them.
Areas of responsibility
Responsibilities of the manufacturer
of the original equipment:
Makita Corporation Anjo,
Aichi 446-8502 Japan /
Makita, Jan-Baptist Vinkstraat 2, 3070,
Belgium
Internet: www.makita.com
The company above is responsible for
supplying the product, including the User
Manual in a completely safe condition.
The company above is not responsible for
third party accessories.
Responsibilities of the person in
charge of the instrument:
To understand the safety instructions on
the product and the instructions in the
User Manual.
To be familiar with local safety regula-
tions relating to accident prevention.
Always prevent access to the product by
unauthorised personnel.
No.
Cause
Correction
204
Calculation error
Perform measurement
again.
252
Temperature too
high
Let device cool down.
253
Temperature too
low
Warm device up.
255
Received signal too
weak, measuring
time too long
Change target surface
(e.g. white paper).
256
Received signal too
high
Change target surface
(e.g. white paper).
257
Too much back-
ground light
Shadow target area.
258
Measurement
outside of meas-
uring range
Correct range.
260
Laser beam inter-
rupted
Repeat measurement.