SR9600 RS-232C Control Specification Page: 16 / 25 Document Version [1.0] Multi Room B POWER Multi Room B SPEAKER Multi Room B AUDIO MUTE Multi Room B VOLUME Multi Room B VOLUME SET Multi Room B SOURCE Select Multi Room B SLEEP Multi Room B Tuner1 Frequency Multi Room B Tuner1 Preset Multi Room B Tuner1 mode Command TOGGLE OFF ON TOGGLE OFF ON TOGGLE OFF ON VALUE UP DOWN VARIABLE FIXED TV DVD VCR1 VCR2 DSS LD AUX1 AUX2 CD CD-R TAPE TUNER1 FM1 AM1 TUNER2 FM2 AM2 "MPW=0" "MPW=1" "MPW=2" "MSP=0" "MSP=1" "MSP=2" "MAM=0" "MAM=1" "MAM=2" "MVL=0xxx" "MVL=1" "MVL=2" "MVS=1" "MVS=2" "MSC=1" "MSC=2" "MSC=3" "MSC=4" "MSC=5" "MSC=6" "MSC=9" "MSC=A" "MSC=C" "MSC=D" "MSC=E" "MSC=F" "MSC=G" "MSC=H" "MSC=J" "MSC=K" "MSC=L" Reply from Slave "MPW=1", (OFF) "MPW=2" (ON) "MSP=1",(OFF) "MSP=2" (ON) "MAM=1", "MAM=2" "MVL=xxx" xxx = vol. value as " 00" ~"-90" "MVS=1", ( VARIABLE) "MVS=2" (FIXED) "MSC=va", (v ,a= '0' - 'Z') (v = video, a = audio.) VALUE OFF "MSL=0xx" ("xx" = min) "MSL=1" "MSL=xx" (xx = min) "MSL=00" VALUE UP DOWN Auto-UP Auto-DOWN VALUE UP DOWN SCAN Start SCAN Stop TOGGLE OFF(MONO) ON(AUTO) "MTF=0xxxxx" (xxxxx = freq.) "MTF=1" "MTF=2" "MTF=3" "MTF=4" "MTP=0ww" (ww = preset nr.) "MTP=1" "MTP=2" "MTP=3" "MTP=4" "MTM=0" "MTM=1" "MTM=2" "MTF=xxxxx" (xxxxx = Frequency) if (xxxxx < 02000) band=AM; else band=FM; (ex."08750" = FM87.50MHz) "MTP=ww" (ww = current preset nr.) (ww = 01 ~??) "MTM=0"( - ), "MTM=1"(MONO), "MTM=2"(AUTO) Company Restricted

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

SR9600
RS-232C Control Specification
Page: 16 / 25
Document Version [1.0]
Company Restricted
Command
Reply from Slave
TOGGLE
“MPW=0”
OFF
“MPW=1”
Multi Room B
POWER
ON
“MPW=2”
“MPW=1”, (OFF)
“MPW=2” (ON)
TOGGLE
“MSP=0”
OFF
“MSP=1”
Multi Room B
SPEAKER
ON
“MSP=2”
“MSP=1”,(OFF)
“MSP=2” (ON)
TOGGLE
“MAM=0”
OFF
“MAM=1”
Multi Room B
AUDIO MUTE
ON
“MAM=2”
“MAM=1”,
“MAM=2”
VALUE
“MVL=0xxx”
UP
“MVL=1”
Multi Room B
VOLUME
DOWN
“MVL=2”
“MVL=xxx”
xxx = vol. value as “ 00” ~”-90”
VARIABLE
“MVS=1”
Multi Room B
VOLUME SET
FIXED
“MVS=2”
“MVS=1”, ( VARIABLE)
“MVS=2” (FIXED)
TV
“MSC=1”
DVD
“MSC=2”
VCR1
“MSC=3”
VCR2
“MSC=4”
DSS
“MSC=5”
LD
“MSC=6”
AUX1
“MSC=9”
AUX2
“MSC=A”
CD
“MSC=C”
CD-R
“MSC=D”
TAPE
“MSC=E”
TUNER1
“MSC=F”
FM1
“MSC=G”
AM1
“MSC=H”
TUNER2
“MSC=J”
FM2
“MSC=K”
AM2
“MSC=L”
Multi Room B
SOURCE Select
“MSC=va”, (v ,a= ‘0’ – ‘Z’)
(v = video, a = audio.)
VALUE
“MSL=0xx”
(“xx” = min)
“MSL=xx” (xx = min)
OFF
“MSL=1”
“MSL=00”
Multi Room B
SLEEP
VALUE
“MTF=0xxxxx“ (xxxxx = freq.)
UP
“MTF=1“
DOWN
“MTF=2“
Auto-UP
“MTF=3“
Multi Room B
Tuner1 Frequency
Auto-DOWN
“MTF=4“
“MTF=xxxxx”
(xxxxx = Frequency)
if (xxxxx < 02000) band=AM;
else band=FM;
(ex.“08750” = FM87.50MHz)
VALUE
“MTP=0ww”
(ww = preset nr.)
UP
“MTP=1”
DOWN
“MTP=2”
SCAN Start
“MTP=3”
Multi Room B
Tuner1 Preset
SCAN Stop
“MTP=4”
“MTP=ww”
(ww = current preset nr.)
(ww = 01 ~??)
TOGGLE
“MTM=0”
OFF(MONO)
“MTM=1”
Multi Room B
Tuner1 mode
ON(AUTO)
“MTM=2”
“MTM=0”( - ),
“MTM=1”(MONO),