Use where local codes permit connecting cabinet-ground conductor to neutral wire.

Page 13 highlights

3. Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw. A E 3-wire connection: Power supply cord Use where local codes permit connecting cabinet-ground conductor to neutral wire. B D E A B C F D A. External ground conductor screw B. Neutral ground wire C. Ground wire (green or bare) of power supply cord D. ¾" (19 mm) UL listed strain relief E. Center silver-colored terminal block screw F. Neutral wire (white or center wire) 4. Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws. C GF A. 3-wire receptacle (NEMA type 10-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with upturned ends E. 3/4" (19 mm) UL listed strain relief F. Ring terminals G. Neutral wire (white or center wire) 1. Loosen or remove center silver-colored terminal block screw. 2. Connect neutral wire (white or center wire) of power supply cord to the center, silvercolored terminal screw of the terminal block. Tighten screw. A C B D E 5. Tighten strain relief screw. 6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with holddown screw. 7. You have completed your electrical connection. Now go to "Venting Requirements." A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. 3/4" (19 mm) UL listed strain relief 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

13
3.
Connect ground wire (green or bare) of direct wire cable to external ground conductor
screw. Tighten screw.
A
C
D
F
B
E
A. External ground conductor screw
B. Neutral ground wire
C. Ground wire (green or bare) of power supply cord
D. ¾" (19 mm) UL listed strain relief
E. Center silver-colored terminal block screw
F. Neutral wire (white or center wire)
4.
Place the hooked ends of the other direct wire cable wires under the outer terminal block
screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
5.
Tighten strain relief screw.
6.
Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
7.
You have completed your electrical connection. Now go to “Venting Requirements.”
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
A
B
D
C
E
F
G
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with upturned ends
E.
3
/
4
" (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral wire (white or center wire)
1.
Loosen or remove center silver-colored terminal block screw.
2.
Connect neutral wire (white or center wire) of power supply cord to the center, silver-
colored terminal screw of the terminal block. Tighten screw.
A
B
C
D
E
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E.
3
/
4
" (19 mm) UL listed strain relief