Maytag MEDB800VB Use and Care Manual - Page 9

Warnin, Warning

Page 9 highlights

Power Supply Cord WARNING Electrical Connection - U.S.A. Only Direct Wire WARNING Fire Hazard Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Ground wire (green or bare wire) must be connected to green ground connector. Connect remaining 2 supply wires to remaining 2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result in death, fire, or electrical shock. 1. Disconnect power. 2. Remove the hold-down screw and terminal block cover. AB CD A. Terminal block cover B. Hold-down screw location C. External ground conductor screw D. Center, silver-colored terminal block screw E. Neutral ground wire E F. Hole below terminal block F opening 3. Install strain relief. Fire Hazard Use 10 gauge solid copper wire. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Ground wire (green or bare wire) must be connected to green ground connector. Connect remaining 2 supply wires to remaining 2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result in death, fire, or electrical shock. Style 1: Power supply cord strain relief ■ Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold in place. Tighten strain relief screws just enough to hold the two clamp sections together. A B C D A. Strain relief tab pointing up B. Hole below terminal block opening C. Clamp section D. Strain relief tab pointing down 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

9
Electrical Connection - U.S.A. Only
Power Supply Cord
WARNIN
G
Fire Hazar
d
Use a new UL liste
d
3
0 amp power supply cor
d
.
Use a UL liste
d
strain relief.
Disconnect power
b
efore making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
G
roun
d
wire (green or
b
are wire) must
b
e connecte
d
to
green groun
d
connector.
Connect remaining 2 supply wires to remaining
2 terminals (gol
d
).
S
ecurely tighten all electrical connections.
Failure to
d
o so can result in
d
eath, fire, or
electrical shock.
Direct Wire
WARNING
Fire Hazard
Use 10
g
au
g
e solid copper wire.
Use a UL listed strain relief.
Disconnect power before makin
g
electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (
g
reen or bare wire) must be connected to
g
reen
g
round connector.
Connect remainin
g
2 supply wires to remainin
g
2 terminals (
g
old).
Securely ti
g
hten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1.
Disconnect power.
2.
AB
C
D
E
F
A. Terminal block cover
B. Hold-down screw location
C. External ground conductor
screw
D. Center, silver-colored
terminal block screw
E. Neutral ground wire
F. Hole below terminal block
opening
Remove the hold-down screw and terminal block cover.
3.
Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a
3
/
4
" (19 mm) UL listed strain relief (UL marking on strain relief).
Put the tabs of the two clamp sections into the hole below the terminal block opening so
that one tab is pointing up and the other is pointing down, and hold in place. Tighten
strain relief screws just enough to hold the two clamp sections together.
A
B
C
D
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down