Miele DA 3490 Operating and Installation manual - Page 11

Automatically switching back the, intensive power level, Automatic Safety Shut-Off

Page 11 highlights

Operation Automatically switching back the intensive power level The intensive level can be programmed to automatically switch back to level 3 after 10 minutes. ^ To set this option, the fan and the overhead lighting must be turned off and the fume deflector pushed in. ^ Press and hold the "-" and "+" buttons for approx. 10 seconds until power level indicator 1 lights up. ^ Then press the following buttons one after another : - overhead lighting I, - the "-" button, and - overhead lighting I again, If the indicators 1 and IS flash, the automatic switch back is not activated. ^ To activate the automatic switch back, press the "+" button. The power level indicators 1 and IS light continuously. To deactivate, press the "-" button. ^ Press the On/Off button K to confirm. ^ If the procedure is not stored within 4 minutes, the hood will automatically default to the "old" data. Automatic Safety Shut-Off If the ventilation system is left on, the fan will turn automatically off 10 hours after the last button was activated. The lighting however will remain on. ^ Press the On/Off button K to turn the fan back on again. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Automatically switching back the
intensive power level
The intensive level can be programmed
to automatically switch back to level
3
after 10 minutes.
^
To set this option, the fan and the
overhead lighting must be turned off
and the fume deflector pushed in.
^
Press and hold the "
" and "
+
" buttons
for approx. 10 seconds until power
level indicator
1
lights up.
^
Then press the following buttons one
after another :
– overhead lighting
I
,
– the "
" button, and
– overhead lighting
I
again,
If the indicators
1
and
IS
flash, the
automatic switch back is not activated.
^
To activate the automatic switch
back, press the "
+
" button.
The power level indicators
1
and
IS
light continuously.
To deactivate, press the "
" button.
^
Press the On/Off button
K
to confirm.
^
If the procedure is not stored within 4
minutes, the hood will automatically
default to the "old" data.
Automatic Safety Shut-Off
If the ventilation system is left on, the
fan will turn automatically off 10 hours
after the last button was activated. The
lighting however will remain on.
^
Press the On/Off button
K
to turn the
fan back on again.
Operation
11