    Display Solutions, Ltd. 2002-2011 Updated on April 28, 2011 This file contains information about NEC projector control commands. Model Name GT60 : GT5000/GT6000 Series GT50 : GT1150/GT2150 Series HT : HT1000/HT1100 Series HT10 : HT410/HT510 Series LT 180 LT180 LT30 : LT25/
  • NEC NP-V260X | RS232 codes- Projectors - Page 2
    supplied USB cable is not supported for the LT220/240/260. * The serial cable, LAN card and LAN cable are separately sold. * The WT610 replaced the WT610 and uses the same command set. (CAUTION) Before making connections, be sure to invalidate the standby mode of the projector and set the "idle mode
  • NEC NP-V260X | RS232 codes- Projectors - Page 3
    [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING" Control Command POWER ON Yes: Supported No: Not supported Serial Wired Wireless port LAN port LAN unit Yes No No 3. Interface Conditions Serial connection The communications method conforms to the RS-232C standard.
  • NEC NP-V260X | RS232 codes- Projectors - Page 4
    No No Yes No P350X/P530W/P420X Yes No No No Yes Yes U300X/U310W Yes No No No Yes No V260X/V260W Yes: Supported No: Not Supported Yes No No No Yes No Baud rate: Data length: Parity bit: Stop bits: Communications mode: 38400 bps (NP600 series, NP610 Series, VT60/VT70
  • NEC NP-V260X | RS232 codes- Projectors - Page 5
    CONTROL connector is a mini DIN 8-pin connector. 1 To TxD of PC 2 3 4 To GND of PC 5 6 7 To RxD of PC 8 * 2, 3, 5, 6, and 8 are used inside the projector. [ GT/LT80/MT/NP1000/VT (except VT70/VT80/VT90)/NP3150/NP905/NP600/NP4000/NP3250/NP610/NP2200/NP216/M300/P420/U300/V300 ] The PC CONTROL connector
  • NEC NP-V260X | RS232 codes- Projectors - Page 6
    .) Response : This returns the value of received ID2 as is. * Projector ID : (8 Bit) This is a projector ID for the projector that sends and receives frames. Command : This specifies a projector ID for the projector that sends and receives commands. (individual notification) Entering 00H or FFH
  • NEC NP-V260X | RS232 codes- Projectors - Page 7
    notification) CAUTION : * When the model code is set to "broadcast notification", the command becomes broadcast notification command, regardless of values of the projector ID. * Model code is specified using upper ranking 4 bits of data length. The lower ranking 4 bits becomes the upper bits of data
  • NEC NP-V260X | RS232 codes- Projectors - Page 8
    ) Power On Command: 02H 00H FFH F0H 00H CKS NAK: A2H 00H 01H 20H 02H DATA01 DATA02 CKS Data Contents DATA01 Error types 00H : Not supported 01H : Parameter error 02H : Operation mode error 03H : Gain-related error 04H : Logo transfer error DATA02 Error description * When not
  • NEC NP-V260X | RS232 codes- Projectors - Page 9
    number of transferred data is not consecutive. USB connection This conforms to the USB1.1 standard. Transfer speed: All speeds (supported) Endpoint: Control transfer Endpoint 0 Device class: HID class (Ver1.1) USB1.1 Standard: Universal Serial Bus Specification Revision 1.1 HID : Human Interface
  • NEC NP-V260X | RS232 codes- Projectors - Page 10
    LAN card that is used. - For information on supported LAN cards, visit: Global: http://www.nec-pj.com/ [Port Number] The TCP port LAMP INFORMATION REQUEST 037-2. LAMP INFORMATION REQUEST 2 037-4. LAMP INFORMATION REQUEST 3 037-7. LAMP INFORMATION REQUEST 4 038. LAMP MODE REQUEST 039. LAMP
  • NEC NP-V260X | RS232 codes- Projectors - Page 11
    098-198. PIP/SIDE BY SIDE SET 110. AUTO FUNCTIONS EXECUTE 111. AUTO ADJUST EXECUTE2 305-1. BASE MODEL TYPE REQUEST 305-3. PROJECTOR INFORMATION REQUEST 03H B1H 00H 00H 03H C5H CKS 03H B6H 00H 00H 01H CKS 03H BAH 00H 00H 01H CKS 00H
  • NEC NP-V260X | RS232 codes- Projectors - Page 12
    version - Not Supported Availability by Model LAMP INFORMATION REQUEST 037-2. LAMP INFORMATION REQUEST 2 037-4. LAMP INFORMATION REQUEST 3 037-7. LAMP INFORMATION REQUEST 4 038. LAMP MODE REQUEST 039. LAMP PROJECTOR INFORMATION
  • NEC NP-V260X | RS232 codes- Projectors - Page 13
    23 24 28 (!) LT30 : NP4000: NP4001: NP62 : firmware version 1.03 or later firmware version 1.04 or later firmware version 1.01 or later firmware version 1.02 or later 5. Command Descriptions Precautions with Inscriptions: (*1) Projector ID It is the value when forwarding a factory
  • NEC NP-V260X | RS232 codes- Projectors - Page 14
    VT595/VT695/VT700, the term "DVI connector" has been changed to "COMPUTER". 006. RUNNING SENSE Function: This command acquires the operation mode of the projector. Command: 00H 81H 00H 00H 00H 81H Response: At the time of a success 20H 81H 01H xxH 01H DATA01 CKS (*1) (*2) (*3) Data Portion
  • NEC NP-V260X | RS232 codes- Projectors - Page 15
    81H 01H xxH 02H DATA1H DATA02 CKS (*1) (*2) (*4) (*3) 007. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of the projector. Command: 00H C0H 00H 00H 00H C0H Response: At the time of a success 20H C0H 01H xxH 80H DATA01 .. DATA128 CKS (*1) (*2) (*3) Data
  • NEC NP-V260X | RS232 codes- Projectors - Page 16
    : 3 04H : 4 05H : 5 DATA08 Type 2 of input terminal to be selected (!1) (!) (!!) 01H : RGB (*5) 02H : VIDEO 03H : S-VIDEO 04H : COMPONENT 05H : Reserved 06H : DIGITAL (*6) 07H : VIEWER 08H : SLOT1 09H : SLOT2 DATA09 Indication signal type * Valid only when Type 2 of input terminal is 02H or 03H x0H
  • NEC NP-V260X | RS232 codes- Projectors - Page 17
    - - * : Supported - : Not supported *1: Only LT240K/260K V300 DATA34 Test pattern display 2 FFH: No display (Normal condition) FFH Other: Displaying Bit 2: BLUE pattern 0 = OFF 1 = ON Bit 1: GREEN pattern 0 = OFF 1 = ON Bit 0: RED pattern 0 = OFF 1 = ON DATA35 .. 50 Reserved DATA51 .. 65 User
  • NEC NP-V260X | RS232 codes- Projectors - Page 18
    Data01 01H 01H 01H 01H 02H 02H 02H 02H 02H 02H 03H 03H 03H 04H 04H 04H 04H 05H 05H 06H 06H 08H 08H 08H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 11H 11H 11H 11H 11H 11H 11H 11H 12H 12H 12H 12H 12H 12H 12H 13H 13H 13H 13H 13H 13H 13H 14H 14H 16H 16H 16H Data70 00H 01H 02H 00H
  • NEC NP-V260X | RS232 codes- Projectors - Page 19
    DATA74 Entry list type 01H : Default 02H : User DATA75 .. 82 Reserved DATA83 On-screen mute 00H (01H) 2 (02H) 2 (02H) 2 (02H) 4 (04H) Data08 RGB RGB VIDEO S-VIDEO COMPONENT COMPONENT DIGITAL DIGITAL VIEWER VIEWER SLOT1 SLOT1 SLOT2 SLOT2 VIDEO S-VIDEO VIEWER (01H) (01H) (02H) (03H) (04H) (04H)
  • NEC NP-V260X | RS232 codes- Projectors - Page 20
    : This command acquires the error information occurring with the projector. Command: 00H 88H 00H 00H 00H 88H Response: At : None bit1 : FPGA error bit2 : Temperature error(Sensor) bit3 : Lamp(or Lamp1) housing error (!) bit4 : Lamp(or Lamp1) data error (!) bit5 : Mirror cover error bit6 : Lamp2
  • NEC NP-V260X | RS232 codes- Projectors - Page 21
    does not accept the other command during power on processing. 016. POWER OFF Function: This command switches off the main power of the projector. Command: 02H 01H 00H 00H 00H 03H Response: At the time of a success 22H 01H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure
  • NEC NP-V260X | RS232 codes- Projectors - Page 22
    10H Component * 11H Component - 12H Component - 1AH DVI (*6) (!2) * 1AH DVI(DIGITAL)(*6) - 1AH HDMI - 1FH Viewer - 20H LAN / NETW ORK - 07H RGB( MT860/LT280 does not support a DVI connector. (!!) HT1000 (!!!) HT410/HT510/HT1100 (!!!!) VT770 support Component and Viewer (!1)
  • NEC NP-V260X | RS232 codes- Projectors - Page 23
    Response: At the time of a success 22H 03H 01H xxH 01H DATA01 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Results 00H : Normal FFH : Error Response: At the time of a failure A2H 03H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * When switch to the Video
  • NEC NP-V260X | RS232 codes- Projectors - Page 24
    022. SOUND MUTE ON Function: This command mutes the sound. Command: 02H 12H 00H 00H 00H 14H Response: At the time of a success 22H 12H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 12H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * Sound mute is
  • NEC NP-V260X | RS232 codes- Projectors - Page 25
    of tint *tint increment/decrement brightness contrast color tint sharpness Not supported "LT170","VT60 series","VT70 series","VT80 series", "VT90 series" Not supported "HT410/HT510","LT180/LT25/LT30/LT35" volume Not supported "LT170","VT60 series","VT70 series" (except "VT80 series, VT90 series
  • NEC NP-V260X | RS232 codes- Projectors - Page 26
    DATA03 : 00H (direct settings) 01H (increment/decrement) DATA04 : lower data (8bit) DATA05 : upper data (8bit) ex.1) volume direct setting (value = 20) DATA01 : 05H (Volume) DATA02 : 00H ("Volume" only) DATA03 : 00H (direct setting) DATA04 : 14H (lower data : 20 = 0014) DATA05 : 00H (upper data
  • NEC NP-V260X | RS232 codes- Projectors - Page 27
    DATA01 .. 02 Results 0000H : Normal 0000H Other : Error Response: At the time of a failure A3H 10H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * Setting Volume to "10" 03H 10H 00H 00H 05H 05H 00H 00H 0AH 00H 27H 030-12. IMAGE MODE ADJUST Function: This command
  • NEC NP-V260X | RS232 codes- Projectors - Page 28
    a success 23H 8AH 01H xxH 62H DATA01 .. DATA98 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 49 : Projector name (NULL termination character string) DATA50 .. 82 : Reserved DATA83 .. 86 : Lamp Hour Meter (second) (!) DATA87 .. 90 : Filter Usage (second) DATA91 .. 94 : Panel Usage (second
  • NEC NP-V260X | RS232 codes- Projectors - Page 29
    of Normal mode values. It is also displayed with truncated a number after decimal point. 037-1. LAMP INFORMATION REQUEST Function: This command acquires the lamp information (in terms of Normal mode (values) of projector. Command: 03H 8CH 00H 00H 00H 8FH Response: At the time of a success 23H
  • NEC NP-V260X | RS232 codes- Projectors - Page 30
    Response: At the time of a failure A3H 94H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 037-4. LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in Eco mode. Command: 03H 96H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01
  • NEC NP-V260X | RS232 codes- Projectors - Page 31
    until lamp warning message starts to appear = 360000/ 3600= 100 hours (!) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!!) Lamp usage time This is the lamp total usage. It is displayed in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is not supported.
  • NEC NP-V260X | RS232 codes- Projectors - Page 32
    INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents DATA01 Target 00H : Lamp1 01H : Lamp2 DATA02 Unit(!4) 00H : Second 01H : Reserved
  • NEC NP-V260X | RS232 codes- Projectors - Page 33
    is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is not supported. 038. LAMP MODE REQUEST Function: This command acquires the setting of the lamp mode of projector. Command: 03H B0H 00H 00H 01H 07H BBH Response: At the time of a success 23H B0H 01H xxH
  • NEC NP-V260X | RS232 codes- Projectors - Page 34
    B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 046. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of projector. Command: 03H B0H 00H 00H 01H C3H 77H Response: At the time of a success 23H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data
  • NEC NP-V260X | RS232 codes- Projectors - Page 35
    02H 03H 02H 0DH Error contents Unknown command. This current model does not support this function. Invalid values specified. Specified terminal is unavailable or cannot be command sends remote control key codes of projector. Command: 02H 0FH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion
  • NEC NP-V260X | RS232 codes- Projectors - Page 36
    DATA01 .. 02 : Remote control key code (Word type) Key number DATA01 DATA02 Key name 1 01H 00H POWER 2 02H 00H POWER ON (!!) 3 03H 00H POWER OFF (!!) 4 04H 00H SOURCE (AUTO) (!!) 5 05H 00H AUTO (!) (!!) 6 06H 00H MENU (!!) (!!!) 7 07H 00H UP (!!) (!!!) 8 08H 00H DOWN (!!) (!!!) 9 09H 00H RIGHT
  • NEC NP-V260X | RS232 codes- Projectors - Page 37
    00H ZOOM POS DOWN (HT) 228 E4H 00H DVI/DVI (DIGITAL) (*6) (!!) 229 E5H 00H LAN 232 E8H 00H D (Passcode screen will be displayed at once) 238 EEH 00H LAMP MODE (!!!) Response: At the time of a success 22H model with the built-in image sensor does not support the AUTO key. Use the AUTO (SHORT) key
  • NEC NP-V260X | RS232 codes- Projectors - Page 38
    : Picture freeze cycle aspect ratio 02H 0FH 00H 00H 02H DATA01 DATA02 CKS Data Portion Contents DATA01/DATA02 A3H/00H : Aspect Ratio all menu functionality (digits 0-9, cursor movement, enter, select, return, back, clear, etc) 02H 0FH 00H 00H 02H DATA01 DATA02 CKS
  • NEC NP-V260X | RS232 codes- Projectors - Page 39
    051. CARBON SAVINGS INFORMATION REQUEST Function: This command acquires the Carbon Saving values on the projector. Command: 03H 9AH 00H 00H 01H DATA01 CKS (*3) Data Portion Contents DATA01 Acquirement items 00H : Total Carbon Savings 01H : Carbon Savings during operation Response: At
  • NEC NP-V260X | RS232 codes- Projectors - Page 40
    060. GAIN PARAMETER REQUEST 2 Function: This command acquires the adjustment values. Command: 03H 04H 00H 00H 03H DATA01 .. DATA03 CKS (*3) Data Portion Contents DATA01 .. 02 Acquirement items (!) DATA03 00H fixed Response: At the time of a success 23H 04H 01H xxH 0DH DATA01 .. DATA13
  • NEC NP-V260X | RS232 codes- Projectors - Page 41
    44H 44H 44H 45H 46H 47H 47H 47H 48H 49H 4AH 4BH 4CH 4CH 4CH 4CH 4CH 4CH 4CH 02H Black Correct / Inv Gain 00H Lamp Output 00H Signal Level / Auto Control 00H Signal Level / R/G/B Gain R 01H Signal Level / R/G/B Gain G 02H Signal Level / R/G/B Gain B 00H Signal Level / Y/Cb/Cr Gain Y 01H
  • NEC NP-V260X | RS232 codes- Projectors - Page 42
    / Vertical 02H Pincushion / Balance 00H Digital Zoom / Zoom 01H Digital Zoom / Horizontal Position 02H Digital Zoom / Vertical Position 00H White Bal. SweetVision Level 94H 00H Vertical Enhancer 95H 00H I/P Converter 96H 00H Lamp Mode Adjust 97H 00H Wall Color Command example: * In case of
  • NEC NP-V260X | RS232 codes- Projectors - Page 43
    the following cases: Input connector switching Video signal switching Volume adjustment 078-1. SETTING REQUEST Function: This command acquires the function information of projector. Command: 00H 85H 00H 00H 01H 00H 86H Response: At the time of a success 20H 85H 01H xxH 20H DATA01 .. DATA32 CKS
  • NEC NP-V260X | RS232 codes- Projectors - Page 44
    DATA01 DATA02 DATA03 01H 00H 03H MT1060/MT1065 01H 01H 03H MT860 01H 02H 03H MT1075 01H 00H 06H NP1000/NP2000 02H 00H 03H LT240/LT260 02H 01H 03H LT220 02H 02H 03H LT240K/LT260K 02H 00H 05H LT245/LT265 02H 00H 06H LT380 02H 01H 06H LT280 03H 00H 06H VT80 Series 03H
  • NEC NP-V260X | RS232 codes- Projectors - Page 45
    time of a failure A0H 85H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 078-2. RUNNING STATUS REQUEST Function: This command acquires the status of the projector operation. Command: 00H 85H 00H 00H 01H 01H 87H Response: At the time of a success 20H 85H 01H xxH 10H DATA01 .. DATA16 CKS
  • NEC NP-V260X | RS232 codes- Projectors - Page 46
    STATUS REQUEST Function: This command acquires the status of input signal of the projector. Command: 00H 85H 00H 00H 01H 02H 88H Response: At the time 03H Component 02H 04H Component 03H 04H DVI(*6) 01H 06H DVI(DIGITAL)(*6) 01H 06H HDMI 01H 06H Viewer 01H 07H LAN 02H 07H
  • NEC NP-V260X | RS232 codes- Projectors - Page 47
    A0H 85H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 078-4. MUTE STATUS REQUEST Function: This command acquires the status of the mute of projector. Command: 00H 85H 00H 00H 01H 03H 89H Response: At the time of a success 20H 85H 01H xxH 10H DATA01 .. DATA16 CKS (*1) (*2) (*3) Data
  • NEC NP-V260X | RS232 codes- Projectors - Page 48
    NAME REQUEST Function: This command acquires the model name of the projector. Command: 00H 85H 00H 00H 01H 04H 8AH Response: At 0CH 0DH 0EH 0FH 00H 01H 02H Unknown command The current model does not support this function. Unvalid values specified. Specified terminal is unavailable or cannot be
  • NEC NP-V260X | RS232 codes- Projectors - Page 49
    01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 097-196.WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of projector. Command: 03H B0H 00H 00H 01H C3H 77H Response: At the time of a success 23H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data
  • NEC NP-V260X | RS232 codes- Projectors - Page 50
    01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 098-198. PIP/SIDE BY SIDE SET Function: This command sets the PIP/SIDE BY SIDE of projector. Command: 03H B1H 00H 00H 03H DATA01 DATA02 DATA03 CKS Data Portion Contents DATA01 C5H fixed DATA02 Update target 00H : MODE 01H : POSITION
  • NEC NP-V260X | RS232 codes- Projectors - Page 51
    functions. Command: 03H B6H 00H 00H 01H DATA01 CKS (*3) Data Portion Contents DATA01 Execution items Focus 00H ! 01H * !: According to projector setting *: Executing Response: At the time of a success 23H B6H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01
  • NEC NP-V260X | RS232 codes- Projectors - Page 52
    Response: At the time of a failure A3H BAH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 305-1. BASE MODEL TYPE REQUEST Function: This command acquires the projector type. Command: 00H BFH 00H 00H 01H 00H C0H Response: At the time of a success 20H BFH 01H xxH 10H DATA01 ... DATA16 CKS
  • NEC NP-V260X | RS232 codes- Projectors - Page 53
    DATA02 DATA03 DATA13 DATA14 00H 01H 00H 03H MT1060/1065 00H 01H 02H 03H MT860 00H 01H 02H 03H MT1075 00H 01H 00H 06H NP1000/NP2000 00H 02H 00H 03H LT240/LT260 00H 02H 01H 03H LT220 00H 02H 02H 03H LT260K 00H 02H 00H 05H LT245/LT265 00H 02H 00H 06H LT380 00H 02H
  • NEC NP-V260X | RS232 codes- Projectors - Page 54
    Projector Processing Status 00H : Idle 04H : Power On 05H : Cooling 06H : Idle(Error Standby) Other : Not Support displaying 04H : LAN displaying 05H : Test Pattern (User) displaying 10H : Signal selection in progress Other : Not Support DATA04 Select source input type 1 01H : 1
  • NEC NP-V260X | RS232 codes- Projectors - Page 55
    .58 SQZ xAH : COMPONENT(60Hz) xBH : COMPONENT(50Hz) xCH : Un known xDH : NTSC xEH : PAL-M xFH : PAL-N FFH : Not Video Input Other : Not Support DATA07 Picture Mute 00H : OFF 01H : ON DATA08 Sound Mute 00H : OFF 01H : ON DATA09 On-screen mute 00H : OFF 01H : ON DATA10...DATA16
  • NEC NP-V260X | RS232 codes- Projectors - Page 56
    of Response DATA01 DATA02 Error types Error description Error contents 00H 00H Unknown command 00H 01H The current model does not support this function. 01H 00H Unvalid values specified. 01H 01H Specified terminal is unavailable or cannot be selected. 01H 02H Selected language
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

======================================================================
Control Commands for NEC Projector (Basic) Rev 4.28.11a
Copyright (C) NEC Display Solutions, Ltd. 2002-2011
----------------------------------------------------------------------
Updated on April 28, 2011
----------------------------------------------------------------------
This file contains information about NEC projector control commands.
Model Name
GT60
: GT5000/GT6000 Series
GT50
:
GT1150/GT2150 Series
HT
: HT1000/HT1100 Series
HT10
: HT410/HT510 Series
LT180
LT180
LT30
: LT25/LT30/LT35 Series
LT
:
LT220/LT240/LT240K/LT260/LT260K/LT245/LT265 Series
LT80
: LT280/LT380 Series
MT70
: MT860/MT1060/MT1065/MT1075 Series
NP60
:
NP40/NP50/NP60 Series
NP62
:
NP41/NP61/NP62 Series
NP1000
: NP1000/NP2000 Series
NP3150
: NP1150/NP2150/NP3150/NP3151W Series
NP4000
:
NP4000/NP4001 Series
NP905
: NP905/NP901W/VT800 Series
NP600
:
NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S Series
VT
:
VT770 Series
VT70
:
VT37/VT47/VT480/VT57/VT570/VT575/VT670/VT676 Series
VT80
:
VT48/VT480/VT580 Series
VT90
:
VT49/VT490/VT590/VT595/VT695 Series
VT700
:
VT700
WT
: WT600/WT610/WT615 Series
NP4100
:
NP4100/NP4100W Series
NP3250
: NP1250/NP2250/NP3250/NP3250W Series
NP610
:
NP310/NP410/NP410W/NP510/NP510W/NP510WS/NP610/NP610S Series
NP2200
:
NP1200/NP2200 Series
NP216
:
NP110/NP115/NP215/NP216 Series
NP64
:
NP43/NP64 Series
M300
:
M260X/M260W/M300X/M300W Series
P420
:
P350X/P350W/P420X Series
U300
:
U300X/U310W Series
V300
:
V260/V260X/V200X Series