037-7. LAMP INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents DATA01 Target 00H : Lamp1 01H : Lamp2 DATA02 Unit(!4) 00H : Second 01H : Reserved 02H : Hour DATA03 Item 00H : Lamp Hour Meter (second)(!2) 01H : Lamp usage time (second)(!3) 04H : lamp remaining amount until lamp warning message ( 100% to -X%(!1) ) 05H : Lamp usage time (Normal mode)(second) (!5) 06H : Lamp usage time (Eco mode)(second) (!5) 08H : Remaining time until lamp warning message starts to appear (in terms of specified values) 09H : Remaining time until lamp warning message starts to appear (in terms of Normal mode values) 0AH : Remaining time until lamp warning message starts to appear (in terms of Eco mode values) 10H : Remaining time until inhibition of lamp usage (in terms of specified values) 11H : Remaining time until inhibition of lamp usage (in terms of Normal mode values) 12H : Remaining time until inhibition of lamp usage (in terms of Eco mode values) Response: At the time of a success 23H 9BH 01H xxH 07H DATA01 to DATA07 CKS (*1) (*2) (*3) Data Portion Contents DATA01 same values as DATA01 of the command DATA02 same values as DATA02 of the command DATA03 same values as DATA03 of the command DATA04 to 07 Acquired information Response: At the time of a failure A3H 9BH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * In case of acquiring lamp's use of hours 03H 9BH 00H 00H 03H 00H 00H 01H CKS Example of acquisition DATA04 DATA05 DATA06 DATA07 : lamp's use of hours 50H 46H 00H 00H : 18000 seconds Lamp Usage = 18000 / 3600 = 5 hour

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

037-7. LAMP INFORMATION REQUEST 4
**********************************************************************
Function:
This command acquires the information on the projector lamp.
Command:
03H
9BH
00H
00H
03H
DATA01
DATA02
DATA03
CKS
(*3)
Data Portion
Contents
-----------------------------------------------------------------
DATA01
Target
00H : Lamp1
01H : Lamp2
DATA02
Unit(!4)
00H : Second
01H : Reserved
02H : Hour
DATA03
Item
00H : Lamp Hour Meter (second)(!2)
01H : Lamp usage time (second)(!3)
04H : lamp remaining amount until lamp warning message
( 100% to -X%(!1) )
05H : Lamp usage time (Normal mode)(second) (!5)
06H : Lamp usage time (Eco mode)(second) (!5)
08H : Remaining time until lamp warning message starts
to appear (in terms of specified values)
09H : Remaining time until lamp warning message starts
to appear (in terms of Normal mode values)
0AH : Remaining time until lamp warning message starts
to appear (in terms of Eco mode values)
10H : Remaining time until inhibition of lamp usage
(in terms of specified values)
11H : Remaining time until inhibition of lamp usage
(in terms of Normal mode values)
12H : Remaining time until inhibition of lamp usage
(in terms of Eco mode values)
Response: At the time of a success
23H
9BH
01H
xxH
07H
DATA01 to DATA07
CKS
(*1) (*2)
(*3)
Data Portion
Contents
-----------------------------------------------------------------
DATA01
same values as DATA01 of the command
DATA02
same values as DATA02 of the command
DATA03
same values as DATA03 of the command
DATA04 to 07
Acquired information
Response: At the time of a failure
A3H
9BH
01H
xxH
02H
DATA01
DATA02
CKS
(*1) (*2)
(*4)
(*3)
Supplement:
* In case of acquiring lamp's use of hours
03H
9BH
00H
00H
03H
00H
00H
01H
CKS
Example of acquisition
DATA04
DATA05
DATA06
DATA07
:
lamp's use of hours
50H
46H
00H
00H
:
18000 seconds
Lamp Usage = 18000 / 3600 = 5 hour