NordicTrack E 7.7 Elliptical English Manual - Page 29

Maintenance And Troubleshooting

Page 29 highlights

MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. See EXPLODED DRAWING C on page 39. Using a flat screwdriver, remove the left Disc (71). CONSOLE TROUBLESHOOTING If the console does not turn on, make sure that the power cord is fully plugged in. If lines appear in the console display, see HOW TO CHANGE CONSOLE SETTINGS on page 27 and adjust the contrast level of the display. Note: For clarity, the left shield and the left disc ring are shown removed in the drawing below. Next, locate the Reed Switch (38). Turn the Pulley (19) until a Magnet (43) is aligned with the Reed Switch. If the console does not display your heart rate when you hold the handgrip heart rate monitor, or if the dis- played heart rate appears to be too high or too low, see step 5 on page 22. 19 HOW TO LEVEL THE ELLIPTICAL If the elliptical rocks slightly on your floor during use, see HOW TO LEVEL THE ELLIPTICAL on page 17. HOW TO CALIBRATE THE RAMP If the ramp is not functioning properly, the ramp may need to be calibrated. To calibrate the ramp, press and hold the Calorie button for several seconds until the test mode appears in the display. Press the Calorie button again. Then, press the 1 Step Ramp increase or decrease button to calibrate the ramp. The ramp will move upward and downward as it calibrates. 43 38 101 When the ramp stops moving, the ramp is calibrated. Then, press the Calorie button repeatedly to exit the calibration mode. Loosen, but do not remove, the indicated M4 x 16mm Screw (101). Slide the Reed Switch (38) slightly closer to or away from the Magnet (43), and then retighten the Screw. Then, rock the Pulley (19) forward and backward just enough that the Magnet passes the Reed Switch repeatedly. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, reattach the left disc. 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

29
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in. If lines appear in the
console display, see HOW TO CHANGE CONSOLE
SETTINGS on page 27 and adjust the contrast level
of the display.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 22.
HOW TO LEVEL THE ELLIPTICAL
If the elliptical rocks slightly on your floor during use,
see HOW TO LEVEL THE ELLIPTICAL on page 17.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, press and
hold the Calorie button for several seconds until the
test mode appears in the display.
Press the Calorie button again. Then, press the 1 Step
Ramp increase or decrease button to calibrate the
ramp. The ramp will move upward and downward as it
calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the Calorie button repeatedly to exit the
calibration mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
See EXPLODED DRAWING C on page 39. Using a
flat screwdriver, remove the left Disc (71).
Note: For clarity, the left shield and the left disc ring are
shown removed in the drawing below.
Next, locate the Reed Switch (38). Turn the Pulley (19)
until a Magnet (43) is aligned with the Reed Switch.
Loosen, but do not remove, the indicated M4 x 16mm
Screw (101). Slide the Reed Switch (38) slightly closer
to or away from the Magnet (43), and then retighten
the Screw. Then, rock the Pulley (19) forward and
backward just enough that the Magnet passes the
Reed Switch repeatedly.
Repeat these actions until the console displays correct
feedback. When the reed switch is correctly adjusted,
reattach the left disc.
MAINTENANCE AND TROUBLESHOOTING
38
101
43
19