MAINTENANCE AND TROUBLESHOOTING MAINTENANCE Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. When the ramp stops moving, the ramp is calibrated. Then, press the Calorie Workouts button repeatedly to exit the calibration mode. To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING If the console does not turn on, make sure that the power cord is fully plugged in. If lines appear in the console display, see HOW TO CHANGE CONSOLE SETTINGS on page 22 and adjust the contrast level of the display. HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, first unplug the power cord. Next, use a flat screwdriver and carefully pry the left Disc Cover (55) off the left Disc (71). 71 If the console does not display your heart rate when 55 you hold the handgrip heart rate monitor, or if the dis- played heart rate appears to be too high or too low, see step 5 on page 17. If the console does not display your heart rate when you use the chest heart rate monitor, see TROUBLESHOOTING on page 10. HOW TO GREASE THE ROLLERS See the EXPLODED DRAWING near the end of this manual. If the Large Rollers (51) squeak when moving on the Tracks (11), first clean the Tracks and the Large Rollers with a lint-free cloth and rubbing alcohol. Next, apply one packet (3 grams) of the included PTFE grease to each Track. Use a lint-free cloth or your fingers to spread the grease evenly along the Tracks. Then, wipe off any excess grease. If the included grease packets have been used or lost, use a highquality clear or white grease instead. Next, turn the left Crank Arm (20) until one of the Magnets (43) on the Pulley (19) is aligned with the Reed Switch (38). Then, loosen, but do not remove, the two M4 x 16mm Screws (104), slide the Reed Switch slightly closer to or away from the Magnet, and retighten the Screws. 104 38 43 HOW TO CALIBRATE THE RAMP 19 20 If the ramp is not functioning properly, the ramp may need to be calibrated. To calibrate the ramp, press and hold the Calorie Workouts button for several seconds until the test mode appears in the display. Next, press the Calorie Workouts button again. Then, press the Power Ramp increase or decrease button to calibrate the ramp. The ramp will move upward and downward as it calibrates. Then, plug in the power cord and turn the left crank arm for a moment. Repeat the procedure above, if necessary, until the console displays correct feedback. Then, reattach the left disc. 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

24
MAINTENANCE
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in.
If lines appear in the console display, see HOW TO
CHANGE CONSOLE SETTINGS on page 22 and
adjust the contrast level of the display.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 17.
If the console does not display your heart rate
when you use the chest heart rate monitor, see
TROUBLESHOOTING on page 10.
HOW TO GREASE THE ROLLERS
See the EXPLODED DRAWING near the end of this
manual. If the Large Rollers (51) squeak when mov-
ing on the Tracks (11), first clean the Tracks and the
Large Rollers with a lint-free cloth and rubbing alcohol.
Next, apply one packet (3 grams) of the included PTFE
grease to each Track. Use a lint-free cloth or your
fingers to spread the grease evenly along the Tracks.
Then, wipe off any excess grease. If the included
grease packets have been used or lost, use a high-
quality clear or white grease instead.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, press and
hold the Calorie Workouts button for several seconds
until the test mode appears in the display.
Next, press the Calorie Workouts button again. Then,
press the Power Ramp increase or decrease button
to calibrate the ramp. The ramp will move upward and
downward as it calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the Calorie Workouts button repeatedly to
exit the calibration mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, first
unplug the power cord.
Next, use a flat
screwdriver
and carefully
pry the left Disc
Cover (55) off
the left Disc
(71).
Next, turn the left Crank Arm (20) until one of the
Magnets (43) on the Pulley (19) is aligned with the
Reed Switch (38). Then, loosen, but do not remove,
the two M4 x 16mm Screws (104), slide the Reed
Switch slightly closer to or away from the Magnet, and
retighten the Screws.
Then, plug in the power cord and turn the left crank
arm for a moment. Repeat the procedure above, if
necessary, until the console displays correct feedback.
Then, reattach the left disc.