Oki B710dn Maintenance Manual - Page 3

B710 B720 and B730 Fuser Counter Reset Procedure

Page 3 highlights

B710 B720 and B730 Fuser Counter Reset Procedure -Instructions for Resetting the Maintenance Counters- First, enter the diagnostic mode in order to do a maintenance counter reset. To enter the Diagnostics area: Turn the printer power OFF. Press and Hold the MENU^ and Enter buttons. Turn the printer power ON (you can release these buttons as soon as "loading ... '' is displayed. The Operator Panel reads "Diagnostics" There is a list of Test Options and settings. Press the Down Arrow highlight "Maintenance Info." Press the Enter button The Operator Panel Display reads "Maintenance Info" with setting listed. Reset Maintenance reqd. is highlighted. Press Enter Reset Maint. Reqd. is displayed and Execute is highlighted. Press Enter. The Display reads -Resetting Maintenance Required. This completes the process. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

3
B710 B720 and B730 Fuser Counter Reset Procedure
-Instructions for Resetting the Maintenance Counters-
First, enter the diagnostic mode in order to do a maintenance counter
reset.
To enter the Diagnostics area:
Turn the printer power OFF.
Press and Hold the MENU^ and Enter buttons.
Turn the printer power ON (you can release these buttons as soon as “loading … ’’ is
displayed.
The Operator Panel reads “Diagnostics”
There is a list of Test Options and settings.
Press the Down Arrow highlight “Maintenance Info.” Press the Enter button
The Operator Panel Display reads “Maintenance Info” with setting listed.
Reset Maintenance reqd. is highlighted. Press Enter
Reset Maint. Reqd. is displayed and Execute is highlighted.
Press Enter.
The Display reads --
Resetting
Maintenance Required
.
This completes the process.