Panasonic 26PEF1U6 26PEU1U6 Owner's Manual - Page 171
Judgment condition, Clear condition, Remote, controller, alarm display, Alarm, contents, Judgment
View all Panasonic 26PEF1U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 171 highlights
4. Service procedures Remote controller alarm display Alarm contents F31 EEPROM trouble Judgment condition Reading/writing failure Clear condition Judgment and correction Recovery at power 1. Check EEPROM (IC007). reset 2. Check outdoor unit control PCB. L02 Mismatch of indoor Indoor unit judges that type Recovery at power 1. Check indoor unit EEPROM. and outdoor unit types does not match outdoor unit reset 2. Check indoor unit control (Espacio, Multi ) type. PCB. L04 Settings failure Duplicated outdoor unit address (system address) Automatic recovery 1. Check outdoor unit system address. 2. Check inter-unit control wiring. L07 Settings failure L10 Settings failure Group control wiring is connected to an independent-control indoor Outdoor unit capacity not set. Recovery at power reset Recovery at power reset 1. Check inter-unit control wiring. 2. Check indoor unit EEPROM. Check outdoor unit EEPROM. L13 Indoor-outdoor unit Outdoor unit judges that type Recovery at power 1. Check indoor unit types does not match indoor unit reset EEPROM. type. 2. Check outdoor unit control PCB. E06 Outdoor unit detected Serial signal receiving failure Automatic abnormal signal from (including failure to verify No. recovery indoor unit. of units) 1. Check inter-unit control wiring. 2. Check outdoor unit E07 Outdoor unit sending Serial signal sending failure Automatic 1. Check inter-unit control failure to indoor unit recovery wiring. 2. Check outdoor unit control PCB. E14 Settings failure Duplicated master unit in Recovery at power 1. Check inter-unit control simultaneous-operation multi reset wiring. control 2. Check indoor unit (Detected by outdoor unit) combination. E15 Automatic address Indoor unit capacity too low. Recovery at power 1. Check inter-unit control setting failure reset wiring. 2. Check outdoor unit control PCB. E16 Automatic address Indoor unit capacity too high. Recovery at power 1. Check inter-unit control setting failure reset wiring. 2. Check outdoor unit control PCB. E20 Automatic address Outdoor unit cannot receive Recovery at power 1. Check inter-unit control 4 setting failure any serial signals from indoor reset wiring. units. 2. Check outdoor unit control PCB. E31 Communications No communication possible Automatic recovery Check outdoor unit control trouble within unit with MDC for 3 minutes or PCB. longer. H01 Overcurrent Inverter stops after alarm is detected. Recovery at restart 1. Refrigerant cycle trouble, overload operation 2. Loose screws between HIC control PCB and radiating plate 3. Cooling failure of radiating plate 4. Check outdoor unit PCB wiring. 4-7