Panasonic 36PST1U6 26PEU1U6 Owner's Manual - Page 36
MODEL No., Source, Controller P.C.B. Ass'y, Compressor, Refrigerant amount at shipment, High
View all Panasonic 36PST1U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
1-2 Major Component Specifications (B) Outdoor Unit MODEL No. Source Controller P.C.B. Ass'y Control circuit fuse (on the P.C.B."FIL-CH4872R") Compressor Model....number Nominal output W Compressor oil cc Coil resistance Ω (Ambient temperature 25 °C) Safety control Microprocessor safety devices Overload protector (Operating temperature) 1 Crank case heater Refrigerant amount at shipment High pressure switch Set pressure Open °F (°C) Close °F (°C) lbs. (kg) OFF PSi Fan Number.. diameter Air circulation (Hi) Fan speeds (Max.) Fan motor Model No. Source No. of pole Nominal output Coil resistance (Ambient temperature 20 °C) Safety device Operating temperature Run capacitor Heat exchanger Coil Rows....fin pitch Face area ON PSi mm m3/h W Ω Open Close VAC, °F (°C) °F (°C) µF mm m2 1. Specifications U-36PE1U6 208 - 230 V / 1 phase / 60 Hz CR-CH4872R (Microprocessor) 280 V, 25 A C - R : 0.665 C - S : 0.665 C-7RVN153H0U 1,500 650 R - S : 0.665 Compressor Discharge Gas temperature control Comressor current detection circuit 230 (110) 203 (95) - R410A - 6.2 (2.8) - 600 456 Propeller 1.... ø460 3,300 ~830 rpm (Inverter drive control) RED - WHT BLK - RED DAJ12-95B61A-CR DC340 V / 3 phase 8 90 : 30.5 WHT - BLK : 30.5 : 30.5 284 (140) - 230V, 40 µF Aluminium plate fin / Copper tube 2.. ..1.8 0.675 1-30