Panasonic ACC-195679 ECOi VRF Systems Catalog - Page 16
Me 2 Series, Ecoi Ex
View all Panasonic ACC-195679 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
ECOi EX™ Series ME 2 SERIES ECOi EX™ 2-WAY VRF HEAT PUMP The new ECOi EX VRF system, redesigned with new DC inverter compressor combination operations and perfected original active oil control system brings the efficiency and reliablity you can count on. MODEL NAME Consisted of U-72ME2U9 U-72ME2U9 U-96ME2U9 U-96ME2U9 U-120ME2U9 U-120ME2U9 U-144ME2U9 U-144ME2U9 WU-168ME2U9 U-72ME2U9 +U-96ME2U9 Appearance Nominal Tons Performance test condition Power supply Cooling capacity Heating capacity Rating Standard AHRI 1230 Electrical ratings Outdoor unit only Indoor unit Cooling High heating 47°F Low heating 17°F Voltage Ducted cooling Ducted heating Non-ducted cooling Non-ducted heating Starting current Capacity EER IEER Capacity COP Capacity COP Running current Power input Power factor Running current Power input Power factor Running current Power input Power factor Running current Power input Power factor Compressor type/quantity Air flow rate External static pressure Refrigerant amount at shipment*2 Btu/h kW Btu/h kW Btu/h Btu/h Btu/h V A kW % A kW % A kW % A kW % A CFM Pa (in. WC) lbs Dimensions H x W x D inch Net weight lbs Ambient temperature operating range Gas inch Diameter Liquid inch Piping Balance inch Connecting method Max total pipe length Ft Elevation difference (OD upper/ OD lower) Ft Operation sound (Normal/Quiet mode) dB Maximum allowable indoor unit connection 6 8 72,000 21.1 81,000 23.7 69,000 | 69,000 12.3 | 12.6 19.1 | 22.1 77,000 | 77,000 3.56 | 3.86 52,000 | 52,000 2.56 | 2.63 14.3 / 13.1 4.49 / 4.49 87 / 86 16.7 / 15.2 5.22 / 5.22 87 / 86 15.7 / 14.4 4.92 / 4.92 87 / 86 16.8 / 15.4 5.28 / 5.28 87 / 86 96,000 28.1 108,000 31.6 92,000 | 92,000 11.9 | 11.9 19.3 | 23.1 103,000 | 103,000 3.54 | 3.75 67,000 | 67,000 2.42 | 2.59 19.0 / 17.4 6.36 / 6.36 93 / 92 21.6 / 19.8 7.16 / 7.16 92 / 91 21.0 / 19.2 7.04 / 7.04 93 / 92 22.2 / 20.3 7.36 / 7.36 92 / 91 Inverter driven Rotary×1 6,000 6,200 R410A / 20.1 R410A / 22.7 10 AHRI Standard 1230 3 208/230V 60Hz 120,000 35.2 135,000 39.6 Ducted | Non-ducted 114,000 | 114,000 11.5 | 11.8 19.3 | 24.8 129,000 | 129,000 3.40 | 3.60 75,000 | 75,000 2.30 | 2.40 208 / 230 24.4 / 22.3 8.25 / 8.25 94 / 93 27.9 / 25.5 9.45 / 9.45 94 / 93 26.4 / 24.1 8.94 / 8.94 94 / 93 28.9 / 26.4 9.78 / 9.78 94 / 93 1 / 1 12 144,000 42.2 162,000 47.5 138,000 | 138,000 10.9 | 10.7 18.7 | 22.6 154,000 | 154,000 3.27 | 3.35 100,000 | 100,000 2.18 | 2.41 31.9 / 28.8 10.8 / 10.8 94 / 94 35.1 / 31.8 11.9 / 11.9 94 / 94 35.7 / 32.3 12.1 / 12.1 94 / 94 37.5 / 33.9 12.7 / 13.7 94 / 94 Inverter driven Rotary×2 7,900 80 7,900 R410A / 18.7 R410A / 26.0 72-33/64" x 30-5/16" x 39-3/8" 72-33/64" x 46-29/64" x 39-3/8" 503 3/4" 3/8" 1/4" 54.5 / 51.5 20 560 664 721 Cooling: 14~122°FDB, Heating: -4~64°FWB 7/8" 1-1/8" 1-1/8" 3/8" 1/2" 1/2" 1/4" 1/4" 1/4" (Liquid,Balance)Flared,(Gas)Brazing ~1,640 164 / 131 58.0 / 55.0 59.5 / 56.5 61.0 / 58.0 25 32 39 * NOTE: *1 If the longest tubing equivalent length exceeds 295 ft. (90m), increase the sizes of the main tubes by 1 rank for gas tubes and liquid tubes. *2 It's necessary to charge additional refrigerant of 70.5 oz (2.0 kg) per one outdoor unit. 16 14 168,000 49.2 189,000 55.4 160,000 | 160,000 11.7 | 11.6 19.0 | 23.2 180,000 | 180,000 3.45 | 3.50 119,000 | 119,000 2.30 | 2.38 35.8 / 32.7 11.6 / 11.6 90 / 89 40.7 / 37.2 13.2 / 13.2 90 / 89 40.1 / 36.7 13.0 / 13.0 90 / 89 44.1 / 40.3 14.3 / 14.3 90 / 89 Inverter driven Rotary 1+1 6,000+6,200 R410A / 20.1+22.7 72-33/64" x 62-63/64" x 39-3/8" 503 + 560 1-1/8" 5/8" 1/4" 60.0 / 57.0 45