Panasonic AW-HE38H Operating Instructions - Page 21

System example 2 (connection with commercially available controller, RS-422 connection)

Page 21 highlights

Installation Instructions Connections (continued) ■■System example 2 (connection with commercially available controller, RS-422 connection) AW‑HE38 RS-422 communication connector Commercially available controller Supplied AC adaptor ●● Configure the service switches at the bottom of the unit. For details on the service switches, see "Service switch settings" (page 42). SW1 SW2 SW3 SW4 SW7 SW8 Camera address setting (standard serial communication) Set to AUTO or 1 to 7. (Set address numbers so that they do not duplicate each other.) Communication format Enable standard serial communication (ON). Communication baud Set to 9600 bps (OFF) or 38400 bps (ON) based on your commercially rate available controller. Communication connector Set to RS-422 (OFF). ●● Configure the following items in the camera menu. 1. Display [System] menu  [Protocol]  [Model Select]. 2. Select [SEVIHD1], [SBRC300], or [SBRCZ330] for the protocol type. Note ●● Daisy-chain connections are not possible for RS-422 connections. 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

21
Installation
Instructions
Connections
(continued)
System example 2 (connection with commercially available controller,
RS-422 connection)
RS-422 communication connector
Commercially
available controller
AW-HE38
Supplied AC adaptor
Configure the service switches at the bottom of the unit.
For details on the service switches, see “Service switch settings” (page 42).
SW1
Camera address
setting (standard
serial communication)
Set to AUTO or 1 to 7.
(Set address numbers so that they do not duplicate each other.)
SW2
SW3
SW4
Communication
format
Enable standard serial communication (ON).
SW7
Communication baud
rate
Set to 9600 bps (OFF) or 38400 bps (ON) based on your commercially
available controller.
SW8
Communication
connector
Set to RS-422 (OFF).
Configure the following items in the camera menu.
1.
Display [System] menu
[Protocol]
[Model Select].
2.
Select [SEVIHD1], [SBRC300], or [SBRCZ330] for the protocol type.
Daisy-chain connections are not possible for RS-422 connections.
Note