System example 1 (connection with commercially available controller, RS-232C daisy-chain connection)
View all Panasonic AW-HN38H manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Connections (continued) ■■System example 1 (connection with commercially available controller, RS-232C daisy-chain connection) AW‑HN40/AW‑HN38* Up to 7 Commercially available controller RS-232C connector RS-232C connector Supplied AC adaptor * You can connect up to seven cameras to a single controller. Supplied AC adaptor ●● Configure the service switches at the bottom of the unit. For details on the service switches, see "Service switch settings" (page 42). SW1 SW2 SW3 SW4 SW7 SW8 Camera address setting (standard serial communication) Set to AUTO or 1 to 7. (Set address numbers so that they do not duplicate each other.) Communication format Enable standard serial communication (ON). Communication baud Set to 9600 bps (OFF) or 38400 bps (ON) based on your commercially rate available controller. Communication connector Set to RS-232C (ON). ●● Configure the following items in the camera menu. 1. Display [System] menu [Protocol] [Model Select]. 2. Select [SEVIHD1], [SBRC300], or [SBRCZ330] for the protocol type. Supplied AC adaptor 20