Panasonic CS-E18RKUAW E18RKUA Submittal Sheet - Page 1

Panasonic CS-E18RKUAW Manual

Page 1 highlights

Split System Submittal Data System: E18RKUA Indoor: CS-E18RKUAW Outdoor: CU-E18RKUA Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) 230/208/1/60 15 20 Compressor No. Used DC Twin Rotary (Inverter) 1 Motor Type (No. of poles) Output Power DC Brushless (4 poles) 1700 Outdoor Unit Fan Type No. Speeds Type Drive No. Poles (RPM) No. Motors (W) CFM (Hi speed) Coil Type Fin Type - Pipe Type Propeller Variable speed Direct / DC Brushless Motor 8-700 1-60 1925 Aluminum Fin and Copper Pipe Coated Corrugated fin - Inner Rifled Rows x stage x F.P.I. Size (W x H x L) 2 x 36 x 19 1-13/32 x 29-25/32 x 34-7/32 Tube Size (in.) 9/32 Indoor Unit Fan Type Motor Type, No. of Poles No. Speeds RPM (Cool / Heat), High No. Motors (W) CFM (Qlo/Lo/Me/Hi/SHi) Cooling CFM (Qlo/Lo/Me/Hi/SHi) Heating Operating Sound-Hi/Me/Lo/ dB-A (Cool) Operating Sound-Hi/Me/Lo/ dB-A (Heat) Cross Flow DC Brushless, 8 poles Variable speed 1,480 / 1,500 1-94.8 469/513/592/670/720 508/553/622/695/740 47/39/36 46/39/36 Coil Type Fin Type - Pipe Type Aluminum Plate Fin & Copper Tube Coated Slit Plate - Inner Rifled Row x stage x FPI Size 2 x 15 x 21 1 x 12-13/32 x 31-7/8 Tube Size (in.) Drain Connection Size (in.) 9/32" 3/4" Refrigerant Oz. - R410a (outdoor unit) R410A 56.5 Refrigerant Control Electronic Expansion Valve Refrigerant Tubing Connections Flare Approval: Date: Construction: Unit#: Drawing#: Line Length, Max (ft.) Elevation Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction) Pre-charge, tubing length at shipment Dimensions (HxWxD) Indoor Unit (Crated) (in.) Indoor Unit (Uncrated) (in.) Outdoor Unit (Crated) (in.) Outdoor Unit (Uncrated) (in.) Weight (lbs.) (Indoor) Net (Indoor) Shipping (Outdoor) Net (Outdoor) Shipping 100.0 49.2 1/4" 1/2" 32.8' 14-17//32 x 45-11/16 x 11-9/32 11-7/16 x 42-5/32 x 9-15/32 34-25/32 x 41-5/16 x 19-1/8 31-5/16 x 34-15/32 x 12-5/8 26 31 132 146

  • 1
  • 2
  • 3

Split System Submittal Data
System:
E18RKUA
Indoor:
CS-E18RKUAW
Outdoor:
CU-E18RKUA
Approval:
Date:
Construction:
Unit#:
Drawing#:
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data
Power (V/P/Hz)
230/208/1/60
Circuit Ampacity (A)
15
Fuse Size, Max.(A)
20
Compressor
DC Twin Rotary (Inverter)
No. Used
1
Motor Type (No. of poles)
DC Brushless (4 poles)
Output Power
1700
Outdoor Unit
Fan Type
Propeller
No. Speeds
Variable speed
Type Drive
Direct / DC Brushless Motor
No. Poles (RPM)
8-700
No. Motors (W)
1-60
CFM (Hi speed)
1925
Coil Type
Aluminum Fin and Copper Pipe
Fin Type - Pipe Type
Coated Corrugated fin - Inner
Rifled
Rows x stage x F.P.I.
2 x 36 x 19
Size (W x H x L)
1-13/32 x 29-25/32 x 34-7/32
Tube Size (in.)
9/32
Indoor Unit
Fan Type
Cross Flow
Motor Type, No. of Poles
DC Brushless, 8 poles
No. Speeds
Variable speed
RPM (Cool / Heat), High
1,480 / 1,500
No. Motors (W)
1-94.8
CFM (Qlo/Lo/Me/Hi/SHi) Cooling
469/513/592/670/720
CFM (Qlo/Lo/Me/Hi/SHi) Heating
508/553/622/695/740
Operating Sound-Hi/Me/Lo/ dB-A
(Cool)
47/39/36
Operating Sound-Hi/Me/Lo/ dB-A
(Heat)
46/39/36
Coil Type
Aluminum Plate Fin & Copper Tube
Fin Type - Pipe Type
Coated Slit Plate - Inner Rifled
Row x stage x FPI
2 x 15 x 21
Size
1 x 12-13/32 x 31-7/8
Tube Size (in.)
9/32”
Drain Connection Size (in.)
3/4”
Refrigerant
R410A
Oz. - R410a (outdoor unit)
56.5
Refrigerant Control
Electronic Expansion Valve
Refrigerant Tubing Connections
Flare
Line Length, Max (ft.)
100.0
Elevation Difference, Max (ft.)
49.2
Line Size (in. O.D. Discharge)
1/4”
Line Size (in. O.D. Suction)
1/2”
Pre-charge, tubing length at
shipment
32.8’
Dimensions (HxWxD)
Indoor Unit (Crated) (in.)
14-17//32 x 45-11/16 x 11-9/32
Indoor Unit (Uncrated) (in.)
11-7/16 x 42-5/32 x 9-15/32
Outdoor Unit (Crated) (in.)
34-25/32 x 41-5/16 x 19-1/8
Outdoor Unit (Uncrated) (in.)
31-5/16 x 34-15/32 x 12-5/8
Weight (lbs.)
(Indoor) Net
26
(Indoor) Shipping
31
(Outdoor) Net
132
(Outdoor) Shipping
146