Panasonic CS-E18RKUAW E18RKUA Submittal Sheet - Page 2
Features, Operating Range, Indoor Air Intake Temp, Outdoor Air Intake Temp, Performance Data @ ARI
View all Panasonic CS-E18RKUAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Performance Data @ ARI Standard Conditions Cooling Total Capacity (BTU/H) 17,200 (5,800-19,800) Sensible Capacity (BTU/H) 15,990 Latent Capacity (BTU/H) 1210 SEER 19.5 Dehumidification (Pints/H) 3.0 Amps (A) 6.3 Power Inputs (W) 1300 Outdoor Sound Rating (dB-A) 49 Heating Total Capacity (BTU/H) 21,600 (5,800-22,00) HSPF 10.0 Amps (A) 8.3 Power Inputs (W) 1750 Outdoor Sounds Rating (dB-A) 51 Features Controls Remote Controller Wired Remote Controller Temperature Control Timer Quiet mode High Power mode Air Louver, Horizontal Air Louver, Vertical Power Failure Automatic Restart Heating/Cooling Automatic Changeover Self-Diagnosis Air Filter Microprocessor LCD Wireless Type included as standard Optional CZ-RD516C-1 IC Thermistor Single Event Daily ON/OFF TIMER Included Included Automatic, Sweep, Step Automatic, Sweep, Step Built-In Built-In Built-In Washable, One-touch Operating Range Cooling (Max) Cooling (Min) Heating (Max) Heating (Min) Indoor Air Intake Temp 89.6F DB/73.4F WB 60.8F DB/51.8F WB 86.0F DB 60.8DB Outdoor Air Intake Temp 114.8F DB 0F DB 75.2F DB/64.4F WB -4.0F DB/-5.8F WB Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon