Panasonic KX-TDA600 Installation Manual

Panasonic KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports Manual

Panasonic KX-TDA600 manual content summary:

  • Panasonic KX-TDA600 | Installation Manual - Page 1
    IP-PBX Installation Manual Model No. KX-TDA600 Thank you for purchasing a Panasonic Hybrid IP-PBX. Please read this manual carefully before using this product and save this manual for future use. KX-TDA600: PLMPR Software File Version 3.1000 or later SD Logo is a trademark. Document Version
  • Panasonic KX-TDA600 | Installation Manual - Page 2
    System Components System Components Table Category Basic Shelf Model No. KX-TDA600 Basic Shelf Description Main Processing Card EMPR Optional Card KX-TDA6105 KX-TDA0196 Optional Shelf Expansion KX-TDA6110 Cards KX-TDA6111 Expansion Shelf KX-TDA620 Main Processing Card (EMPR) Memory
  • Panasonic KX-TDA600 | Installation Manual - Page 3
    Card (OPB3) 4-Channel Message Card (MSG4) CTI Link Card (CTI-LINK) 16-Channel Echo Canceller Card (EECHO16) SD Memory Card for Software Upgrade to Enhanced Version L-Type Power Supply Unit (PSU-L) M-Type Power Supply Unit (PSU-M) 2-Channel Cell Station Unit Using a DHLC/DLC Card (PTinterface CS) for
  • Panasonic KX-TDA600 | Installation Manual - Page 4
    Card for Software Upgrade to Enhanced Version S-Type Power Supply Unit (PSU-S) Available Proprietary Telephones The Hybrid IP-PBX supports Panasonic KX-T7000, KX-TD7000, and KX-NT series telephones: • Digital/Analog/IP proprietary telephones (e.g., KX-T7625, KX-T7630, KX-T7633, KX-T7636, KXNT136
  • Panasonic KX-TDA600 | Installation Manual - Page 5
    is supported. Satisfactory performance cannot be guaranteed for the following: - interoperability and compatibility with all devices and systems connected to this product - proper operation and compatibility with services provided by telecommunications companies over connected networks Installation
  • Panasonic KX-TDA600 | Installation Manual - Page 6
    type of power supply to your home, consult your dealer or local power company. 8. For safety purposes this unit is equipped with a grounded plug. If you do not have a grounded outlet, please have one installed. Do not bypass this safety feature by tampering with the plug. 9. Do not allow anything
  • Panasonic KX-TDA600 | Installation Manual - Page 7
    SAVE THESE INSTRUCTIONS Installation Manual 7
  • Panasonic KX-TDA600 | Installation Manual - Page 8
    Precaution WARNING DO NOT REMOVE SD MEMORY CARD WHILE POWER IS SUPPLIED TO THE HYBRID.IP-PBX Doing so may cause the Hybrid IP-PBX to fail to start when you try to restart the system. 8 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 9
    Contact your telephone company. If all SLTs operate properly, there may be a problem with your Hybrid IP-PBX. Do not reconnect the Hybrid IP-PBX to the CO lines until it has been serviced by an authorized Panasonic Factory Service Center. • Wipe the unit with a soft cloth. Do not clean with abrasive
  • Panasonic KX-TDA600 | Installation Manual - Page 10
    PC Programming Manual. 6. If a system password is forgotten, it can be found by loading a backup of the system data into a PC, and checking the password using the KX-TDA600 Maintenance Console software. If you do not have a backup of the system data, you must reset the PBX to its factory defaults
  • Panasonic KX-TDA600 | Installation Manual - Page 11
    repairs. Product Service Panasonic Factory Servicenters for this product are listed in the servicenter directory. Consult your certified Panasonic dealer for detailed instructions. For Future NO. SERIAL NO. DATE OF PURCHASE NAME OF DEALER DEALER'S ADDRESS DEALER'S TEL. NO. Installation Manual 11
  • Panasonic KX-TDA600 | Installation Manual - Page 12
    installing the hardware, and programming the Hybrid IP-PBX using the KX-TDA600 Maintenance Console. The Structure of this Manual This manual contains the following sections: Section 1 System Outline Provides general information on the Hybrid IP-PBX, including the system capacity and specifications
  • Panasonic KX-TDA600 | Installation Manual - Page 13
    must be performed by a qualified professional installer. If required, provide the telephone company with the following technical information: • Telephone numbers to which the system will be connected • Make: Panasonic • Model: KX-TDA600 • Certification No.: found on the side of the unit • Ringer
  • Panasonic KX-TDA600 | Installation Manual - Page 14
    or late evenings. WARNING The software contained in the ARS and TRS features to allow user access to the network must be upgraded to recognize newly established network area codes and exchange codes as they are placed into service. Failure to upgrade the premises PBXs or peripheral equipment to
  • Panasonic KX-TDA600 | Installation Manual - Page 15
    void user's installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user the dealer or an installed and operated in accordance with provided instructions in the area instruct you not to do so
  • Panasonic KX-TDA600 | Installation Manual - Page 16
    1.3.1 Optional Equipment ...30 1.4 Specifications...32 1.4.1 General Description ...32 1.4.2 Characteristics ...34 1.4.3 System Capacity ...35 2 Installation 41 2.1 Before Installation...42 2.1.1 Before Installation ...42 2.2 Installation of the Hybrid IP-PBX 44 2.2.1 Unpacking ...44 2.2.2 Names
  • Panasonic KX-TDA600 | Installation Manual - Page 17
    IP-PBX 205 3 Guide for the KX-TDA600 Maintenance Console 209 3.1 Overview ...210 3.1.1 Overview ...210 3.2 Connection ...211 3.2.1 Connection...211 3.3 Installation of the KX-TDA600 Maintenance Console 213 3.3.1 Installing and Starting the KX-TDA600 Maintenance Console 213 4 Troubleshooting
  • Panasonic KX-TDA600 | Installation Manual - Page 18
    4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 Troubleshooting ...218 Installation ...218 Connection ...220 Operation ...222 Using the Reset Button 224 Troubleshooting by Error Log 225 Index ...227 18 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 19
    Section 1 System Outline This section provides general information on the Hybrid IPPBX, including the system capacity and specifications. Installation Manual 19
  • Panasonic KX-TDA600 | Installation Manual - Page 20
    Computer Telephony Integration (CTI) Features Computers can be connected to the Hybrid IP-PBX to provide extension users with access to advanced features such as pop-up display of caller information, computer-based speed dialing, etc. PC Phone/PC Console These Panasonic CTI applications can be used
  • Panasonic KX-TDA600 | Installation Manual - Page 21
    Simplified Voice Message (SVM) Features By just installing an optional voice message card in the Hybrid IP-PBX, simple answering machine services can be provided. Cellular Phone Features (KX-TDA6920 required) This Hybrid IP-PBX supports the use of cellular phones and other outside destinations with
  • Panasonic KX-TDA600 | Installation Manual - Page 22
    card for controlling the Hybrid IP-PBX. To use the basic system, install a power supply unit (PSU) in the PSU Slot and optional service cards in Free Slots. To expand to a multipleshelf system, you also need to install a BUS-M card in the BUS-M Card Slot. Basic Shelf (KX-TDA600) Construction of the
  • Panasonic KX-TDA600 | Installation Manual - Page 23
    and install a power supply unit (PSU) in the PSU Slot and optional service cards in Free Slots. Up to 3 Expansion Shelves can be connected to the Basic Shelf. Expansion Shelf (KX-TDA620) Construction of an Expansion Shelf Free Slots PSU Slot BUS-S Card Expansion Shelf (KX-TDA620) Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 24
    system (Basic Shelf + 1 Expansion Shelf). Expansion Shelf 1 is mounted on the Basic Shelf. Note If you are installing a 2-shelf system in an area prone to earthquakes, make sure to fix the system to the wall using the wall brackets (supplied with an optional Mounting Kit). 24 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 25
    1.2 System Construction 3-shelf System (Tower Type) Expanded system (Basic Shelf + 2 Expansion Shelves). Expansion Shelves 1 and 2 are mounted on the Basic Shelf. A Mounting Kit is required for the 3-shelf system. Installation Manual 25
  • Panasonic KX-TDA600 | Installation Manual - Page 26
    1.2 System Construction 4-shelf System (Tower Type) Fully expanded system (Basic Shelf + 3 Expansion Shelves). Expansion Shelves 1 to 3 are mounted on the Basic Shelf. A Mounting Kit is required for the 4-shelf system. 26 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 27
    Type) When vertical space is limited, it is possible to install a fully expanded system (Basic Shelf + Expansion Shelf 1, and Expansion Shelf 2 + Shelf, and Expansion Shelf 3 is mounted on Expansion Shelf 2. Installing the system using base stands (supplied with an optional Mounting Kit) makes it
  • Panasonic KX-TDA600 | Installation Manual - Page 28
    & Door Opener BGM/Music On Hold (MOH) Pager/ Amplifier Speaker IP-PT PC SLT Fax Machine Wireless Phone ISDN Telephone SLT DPT CTI Server PC PC APT DSS Console PS CS DPT DSS Console USB KX-T7636/ PC KX-T7633 Voice Processing System KX-T7600 DPT KX-T7600 DPT 28 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 29
    PC SLT Wireless PT-interface PS Phone CS Voice KX-T7600 KX-T7600 Processing DPT DPT System SLT Wireless Phone Fax Machine LAN CS PS LAN IP-PT Doorphone & Door Opener PC CTI Server External Sensor/External Relay Device USB CTI Server Radio Amplifier Pager/Speaker Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 30
    KX-TDA0103 KX-TDA0104 KX-TDA0143 KX-TDA0144 KX-TDA0161 KX-TDA0164 KX-TDA0168 KX-TDA0170 KX-TDA0171 KX-TDA0172 KX-TDA0173 KX-TDA0187 KX-TDA0190 KX-TDA0191 KX-TDA0193 KX-TDA0196 KX RMT) Analog modem card for remote communication with the Hybrid IP-PBX. V90 support. To be mounted on the EMPR card. PRI
  • Panasonic KX-TDA600 | Installation Manual - Page 31
    transfer (PFT) ports. Mounting Kit Mounting Kit for expanding to a 3- or 4- shelf system. SD Memory Card for Software Upgrade to Enhanced Version Optional SD Memory Card to use enhanced features. For more details, refer to the SD Memory Card Installation/Upgrade Guide. Installation Manual 31
  • Panasonic KX-TDA600 | Installation Manual - Page 32
    1.4 Specifications 1.4 Specifications 1.4.1 General Description Control Bus shelf) Music on Hold (MOH) Paging Serial Interface Port Internal External RS-232C USB Original bus (16-bit, 8 MHz, 10 megabytes per second) H.100 in 1 dB steps) 1 (maximum 115.2 kbps) 1 32 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 33
    1.4 Specifications Extension Connection Cable wire (T, R, D1, D2) APT 2-pair wire (T, R, D1, D2) PT-interface CS 1-pair wire (D1, D2) DSS Console and Add-on 1-pair wire (D1, D2) Key Module 430 mm (W) × 415 mm (H) × 270 mm (D) (17-1/5 in Supply (UPS) is recommended. Installation Manual 33
  • Panasonic KX-TDA600 | Installation Manual - Page 34
    and must be grounded through the EIO4 card. For the connection diagram, refer to "2.8.3 EIO4 Card (KX-TDA0164)". The Hybrid IP-PBX detects input from the sensor when the signal is under 100 Ω. Paging Terminal Impedance 600 Ω MOH (Music on Hold) Terminal 10 000 Ω Impedance 34 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 35
    1.4 Specifications 1.4.3 System Capacity Number of Free Slots The Hybrid IP-PBX supports the following number of free slots for optional service cards. Basic System 10 2-shelf System 21 3-shelf System 32 4-shelf System 43 Maximum CO Line and Extension The Hybrid IP-PBX supports the following
  • Panasonic KX-TDA600 | Installation Manual - Page 36
    Specifications Cards Installed in the Slots of the Hybrid IP-PBX The following number of optional service cards can be installed in the Free Slots of the Hybrid IP-PBX. In addition, a single BUS-M card can be installed in the BUS-M Card Slot of the Basic Shelf. Card Type CO Line Card Basic System
  • Panasonic KX-TDA600 | Installation Manual - Page 37
    of items of terminal equipment can be supported by the Hybrid IP-PBX. Terminal Equipment Type Telephone (using Digital XDP) Basic System 160 (288)*1 2-shelf System 320 (576)*1 3-shelf System 480 (800)*1 4-shelf System 640 (960)*1 SLT 160 320 480 640 KX-T7600 series DPT 256 512 640 640
  • Panasonic KX-TDA600 | Installation Manual - Page 38
    port) Equipment Type KX-T7600 series DPT/KX-T7600 series DSS console Other DPT/Other DSS console APT IP-PT DHLC8 SLC8 ESLC16 EMSLC16 Load Figure 1 4 4 0 8 8 16 16 4 4 1 *1 Only the extension cards that can support SLTs count for the load figures. PSU Capacity Each PSU supports a different load
  • Panasonic KX-TDA600 | Installation Manual - Page 39
    1.4 Specifications Calculation Example KX-T7600 series DPT Other DPT ESLC16 EMSLC16 VPS Total Equipment Type 48 units 4 units 1 card 3 cards 8 ports Load Figure 48 16 16 48 8 136 The total load figure is 136. As this is between 128 and 512, you must install the PSU-L. Installation Manual 39
  • Panasonic KX-TDA600 | Installation Manual - Page 40
    1.4 Specifications 40 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 41
    to install the Hybrid IPPBX. Detailed instructions for planning the installation site, installing the shelves and optional service cards, and cabling of peripheral equipment are provided. Further information on system expansion and peripheral equipment installation is included. Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 42
    taken during installation. Installation Precautions This Hybrid IP-PBX is designed for both floor standing and wall mounting, and should be installed in a location where it is accessible for inspections and maintenance. To prevent malfunction, noise, or discoloration, avoid installing the system in
  • Panasonic KX-TDA600 | Installation Manual - Page 43
    Mis-wiring may cause the Hybrid IP-PBX to operate improperly. Refer to Section 2 "Installation" when wiring the system. 7. If an extension does installed. Do not bypass this safety feature by tampering with the plug. 9. Use twisted pair cable for CO line connection. 10. CO lines should be installed
  • Panasonic KX-TDA600 | Installation Manual - Page 44
    of the Hybrid IP-PBX 2.2 Installation of the Hybrid IP-PBX 2.2.1 Unpacking Supplied Items for the Basic Shelf (KX-TDA600) Unpack the box and check the items below: Main Unit 1 Metal Bracket 1 Anchor Plug 4 Fan Guard 2 Mini Plug (for pager and music source) 4 SD Memory
  • Panasonic KX-TDA600 | Installation Manual - Page 45
    of the Hybrid IP-PBX Supplied Items for the Mounting Kit (KX-TDA6201) Unpack the box and check the items below: Wall Bracket (Right) 2 Wall Bracket (Left) 2 Base Stand 4 Support Bracket 4 Washer 16 Screw D 8 Notes • • If you are installing a multiple-shelf system in an area
  • Panasonic KX-TDA600 | Installation Manual - Page 46
    2.2 Installation of the Hybrid IP-PBX 2.2.2 Names and Locations Inside View Basic Shelf (KX-TDA600) D C B A Expansion Shelf (KX-TDA620) B A E F GH A. RUN Indicator B. ALARM Indicator C. USB Port D. RS-232C Port E. PSU Slot F. Free Slots 1 to 10 (from the left) G. EMPR Card H. BUS-M Card Slot
  • Panasonic KX-TDA600 | Installation Manual - Page 47
    2.2 Installation of the Hybrid IP-PBX 2.2.3 Opening/Closing the Front Cover Opening the Front Cover 1. Insert a flathead screwdriver into the opening (on the left screw counterclockwise to loosen. 3. Slide the front cover to the right until it stops, then lift the front cover. Installation Manual 47
  • Panasonic KX-TDA600 | Installation Manual - Page 48
    . 2. Turn the screw clockwise to tighten. 3. Secure the screw cover. 2 1 Notes • • For safety reasons, close the front cover and tighten the screw before operating the Hybrid IP-PBX. Do not forget to tighten the screw before securing the screw cover. 48 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 49
    of the Hybrid IP-PBX 2.2.4 Attaching Fan Guards Attaching Fan Guards Fan Guards (supplied with the shelf) must be attached using the screws (C) when: • installing a multiple-shelf system, • mounting the shelf on the wall, or • installing the shelf near the wall to protect the air vents on
  • Panasonic KX-TDA600 | Installation Manual - Page 50
    of the Hybrid IP-PBX 2.2.5 Installation of Basic System or 2-shelf System (Floor Standing) The Hybrid IP-PBX can be expanded to a 2-shelf system by mounting an Expansion Shelf on the Basic Shelf. Construction of Basic System or 2-shelf System Expansion Shelf 1 2-shelf System Basic System Metal
  • Panasonic KX-TDA600 | Installation Manual - Page 51
    of the Hybrid IP-PBX Installing the Basic Shelf For the basic system, install the metal bracket (supplied with the Basic Shelf) on the floor first. Then, attach the Basic Shelf to the metal bracket. 1. Install 4 anchor plugs on the floor, using the metal bracket as a template. Fix the metal
  • Panasonic KX-TDA600 | Installation Manual - Page 52
    of the Hybrid IP-PBX 3. Secure the Basic Shelf to the metal bracket with 2 screws (B). Screw (B) Installation of the basic system is complete. If you are installing a 2-shelf system, follow the procedure below. Mounting Expansion Shelf 1 For the 2-shelf system, attach the metal bracket (supplied
  • Panasonic KX-TDA600 | Installation Manual - Page 53
    2. Fix the metal bracket to the Basic Shelf with 4 screws (B). Screw (B) Metal Bracket TOP 2.2 Installation of the Hybrid IP-PBX 3. Lift Expansion Shelf 1, attach it to the metal bracket on the Basic Shelf, and slide it backwards until it locks. Metal Bracket 1 2 Installation Manual 53
  • Panasonic KX-TDA600 | Installation Manual - Page 54
    2.2 Installation of the Hybrid IP-PBX 4. Secure Expansion Shelf 1 to the metal bracket with 2 screws (B). Screw (B) Shelf installation is complete. Next, it is necessary to connect the shelves. 54 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 55
    of the Hybrid IP-PBX Connecting Shelves For the 2-shelf system, you need to install an optional BUS-M card in Shelf 1. For details about the cards, refer to "2.4.1 BUS-M Card (KX-TDA6110)" and "2.5.1 BUS-S Card". Note When installing or removing the BUS-M card, make sure that the DC power supply is
  • Panasonic KX-TDA600 | Installation Manual - Page 56
    2.2 Installation of the Hybrid IP-PBX 3. Turn the 2 screws clockwise to fix the BUS-M card in place. Screws 4. Plug the Bus Cable into the bottom port of the plugging or unplugging the Bus Cable, make sure that the DC power supply is turned off. Bus Cable For Expansion Shelf 1 56 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 57
    of the Hybrid IP-PBX 5. Attach the noise shield wires of the Bus Cable to the Basic Shelf and Expansion Shelf 1 with the screws of the BUS-M card. Note When attaching or removing the noise shield wires, make sure that the DC power supply is turned off. Screw Noise Shield Wire Installation Manual 57
  • Panasonic KX-TDA600 | Installation Manual - Page 58
    of the Hybrid IP-PBX 2.2.6 Installation of 3- or 4-shelf System (Tower Type) The Hybrid IP-PBX can be expanded to a 3- or 4-shelf system by mounting Expansion Shelves on the Basic Shelf. For a 3- or 4-shelf system, you need a Mounting Kit, which supplies you with the base stands and wall
  • Panasonic KX-TDA600 | Installation Manual - Page 59
    of the Hybrid IP-PBX Notes • • • • • • Make sure to remove the front cover from each shelf before installing the shelves (refer to "2.2.3 Opening/Closing the Front Cover"). Do not install any optional service cards or a PSU in the shelves before installation. Do not block the openings of
  • Panasonic KX-TDA600 | Installation Manual - Page 60
    2.2 Installation of the Hybrid IP-PBX 2. Place the metal bracket on the base stands. Metal Bracket 3. Attach the metal bracket to the base stands with 4 screws (B). Screw (B) 60 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 61
    2.2 Installation of the Hybrid IP-PBX 4. Make 4 holes for anchor plugs on the floor, using the measurements indicated here. 287 mm (11-5/16 in) 95 mm (3-3/4 in) (15-1/16 in) * If the direction of the base stands is reversed, the measurement must be 443.4 mm (17-7/ 16 in). Installation Manual 61
  • Panasonic KX-TDA600 | Installation Manual - Page 62
    of the Hybrid IP-PBX 5. Install 4 anchor plugs in the holes on the floor. Then, fasten the base stands to the floor loosely with 4 screws (A). (This makes 6. Remove the 4 tabs on the top cover of the Basic Shelf, by using a flathead screwdriver, as shown below. Basic Shelf 62 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 63
    2.2 Installation of the Hybrid IP-PBX 7. Lift the Basic Shelf, attach it to the metal bracket, and slide it backwards until it locks. Metal Bracket 8. Secure the Basic Shelf to the metal bracket with 2 screws (B). 1 2 TOP FRONT Screw (B) Installation Manual 63
  • Panasonic KX-TDA600 | Installation Manual - Page 64
    2.2 Installation of the Hybrid IP-PBX Mounting Expansion Shelves 1 and 2 For the 3- or 4-shelf system, attach the metal bracket (supplied with the Expansion Shelf) to the Basic cover of Expansion Shelf 1, by using a flathead screwdriver, as shown below. Expansion Shelf 1 64 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 65
    2.2 Installation of the Hybrid IP-PBX 3. Lift Expansion Shelf 1, attach it to the metal bracket on the Basic Shelf, and slide it backwards until it locks. Metal Bracket 4. Secure Expansion Shelf 1 to the metal bracket with 2 screws (B). 1 2 Screw (B) Installation Manual 65
  • Panasonic KX-TDA600 | Installation Manual - Page 66
    2.2 Installation of the Hybrid IP-PBX Fixing to the Wall 1. Attach the metal bracket to the wall brackets. Metal Bracket Wall Bracket (Left) Wall Bracket (Right) 2. Fix the metal bracket to Expansion Shelf 1 with 4 screws (D). Screw (D) 66 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 67
    Hybrid IP-PBX 3. Install 4 anchor plugs in the wall, using the wall brackets as a template. Fix the wall brackets to the wall with 4 screws (A). CAUTION • Drive mounting screws into the wall. Be careful to avoid touching any metal laths, wire laths or metal plates in the wall. • When installing
  • Panasonic KX-TDA600 | Installation Manual - Page 68
    2.2 Installation of the Hybrid IP-PBX 4. Check that the shelves are standing exactly vertically. If the shelves are leaning slightly to one side, move the base stands screws connecting the base stands to the floor. Wall Base Stand Floor 95 mm (3-3/4 in) 382 mm (15-1/16 in) 68 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 69
    of the Hybrid IP-PBX Expansion Shelf 2 1. Lift Expansion Shelf 2, attach it to the metal bracket fixed on Expansion Shelf 1, and slide it backwards until it locks. 1 2 Metal Bracket 2. Secure Expansion Shelf to the metal bracket 2 with 2 screws (B). Screw (B) Installation of a 3-shelf system is
  • Panasonic KX-TDA600 | Installation Manual - Page 70
    2.2 Installation of the Hybrid IP-PBX Mounting Expansion Shelf 3 For the 4-shelf system, attach the metal bracket (supplied with Expansion Shelf 3) to Expansion Shelf 2 first. Then 2. Fix the metal bracket to Expansion Shelf 2 with 4 screws (B). Screw (B) Metal Bracket TOP 70 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 71
    2.2 Installation of the Hybrid IP-PBX 3. Remove the 4 tabs on the top cover of Expansion Shelf 3, by using a flathead screwdriver, as shown below. Expansion (This makes it easy to adjust the position of the shelves later.) Screw (D) Wall Bracket (Left) Wall Bracket (Right) Installation Manual 71
  • Panasonic KX-TDA600 | Installation Manual - Page 72
    2.2 Installation of the Hybrid IP-PBX 5. Lift Expansion Shelf 3, attach it to the metal bracket fixed on Expansion Shelf 2, and slide it backwards until it locks. Metal Bracket 1 2 72 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 73
    2.2 Installation of the Hybrid IP-PBX 6. Secure Expansion Shelf 3 to the metal bracket with 2 screws (B). Screw (B) Installation Manual 73
  • Panasonic KX-TDA600 | Installation Manual - Page 74
    of the Hybrid IP-PBX Fixing to the Wall 1. Install 4 anchor plugs in the wall, using the wall brackets as a template. Fix the wall brackets to the wall with 4 screws Hammer Anchor Plug 30 mm (1-3/16 in) 8 mm (5/16 in) Screw (A) Washer Wall Bracket 1731 mm (68-1/8 in) 74 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 75
    2.2 Installation of the Hybrid IP-PBX 2. Check that the shelves are standing exactly vertically. If the upper shelves are wall brackets to Expansion Shelf 3. Wall Bracket Expansion Shelf 3 Wall Floor Shelf installation is complete. Next, it is necessary to connect the shelves. Installation Manual 75
  • Panasonic KX-TDA600 | Installation Manual - Page 76
    of the Hybrid IP-PBX Connecting Shelves For a 3- or 4-shelf system, you need to install an optional BUS-M card about the cards, refer to "2.4.1 BUS-M Card (KX-TDA6110)", "2.4.2 BUS-ME Card (KXTDA6111)", and "2.5.1 BUS-S Card". Note When installing or removing the BUS-M card, make sure that the
  • Panasonic KX-TDA600 | Installation Manual - Page 77
    2.2 Installation of the Hybrid IP-PBX 2. Insert the BUS-M card along the guide rails in the BUS-M Card Slot (the right-most slot) of the Basic Shelf. Guide Rail 3. Push the release lever in the direction of the arrow so that the BUS-M card engages securely with the connector on the back board.
  • Panasonic KX-TDA600 | Installation Manual - Page 78
    the Hybrid IP-PBX 5. Plug each Bus Cable into the corresponding port of the BUS-M card in the Basic Shelf. Then, plug the other end into the BUS-S card in each Expansion Shelf. Note When plugging or unplugging the Bus Cables, make sure that the DC power supply is turned off. 78 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 79
    the Hybrid IP-PBX 6. Attach the noise shield wires of each Bus Cable to the Basic Shelf and each Expansion Shelf with the screws of the BUS-M card. Note When attaching or removing the noise shield wires, make sure that the DC power supply is turned off. Screw Noise Shield Wire Installation Manual 79
  • Panasonic KX-TDA600 | Installation Manual - Page 80
    Hybrid IP-PBX 2.2.7 Installation of 4-shelf System (Side-by-side Type) When vertical space is limited, it is possible to install shelves side-by-side. Installing the system . Make sure that the surface behind the shelf is flat and free of obstacles, so that the openings on the back of the shelf
  • Panasonic KX-TDA600 | Installation Manual - Page 81
    Hybrid IP-PBX Installing the Basic Shelf and Expansion Shelf 1 To install the Basic Shelf, attach the metal bracket (supplied with the Basic Shelf) to the base stands (supplied with the optional Mounting Kit) first. Then, install the base stands on the floor and fix the Basic Shelf to it. To install
  • Panasonic KX-TDA600 | Installation Manual - Page 82
    2.2 Installation of the Hybrid IP-PBX 2. Place the metal bracket on the base stands. Metal Bracket 3. Attach the metal bracket to the base stands with 4 screws (B). Screw (B) 82 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 83
    2.2 Installation of the Hybrid IP-PBX 4. Make 4 holes for anchor plugs on the floor, using the measurements indicated here. 287 mm (11-5/16 in) 95 mm (3-3/4 in) (15-1/16 in) * If the direction of the base stands is reversed, the measurement must be 443.4 mm (17-7/ 16 in). Installation Manual 83
  • Panasonic KX-TDA600 | Installation Manual - Page 84
    of the Hybrid IP-PBX 5. Install 4 anchor plugs in the holes on the floor. Then, fasten the base stands to the floor with 4 screws (A). Screw (A) Washer 6. Remove the 4 tabs on the top cover of the Basic Shelf, by using a flathead screwdriver, as shown below. Basic Shelf 84 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 85
    2.2 Installation of the Hybrid IP-PBX 7. Lift the Basic Shelf, attach it to the metal bracket, and slide it backwards until it locks. Metal Bracket 8. Secure the Basic Shelf to the metal bracket with 2 screws (B). 1 2 TOP FRONT Screw (B) Installation Manual 85
  • Panasonic KX-TDA600 | Installation Manual - Page 86
    Installation of the Hybrid IP-PBX Expansion Shelf 1 1. Fix the metal bracket to the Basic Shelf with 4 screws (B). Screw (B) Metal Bracket TOP 2. Remove the 4 tabs on the top cover of Expansion Shelf 1, by using a flathead screwdriver, as shown below. Expansion Shelf 1 86 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 87
    2.2 Installation of the Hybrid IP-PBX 3. Fasten the wall brackets loosely to Expansion Shelf 1 with 4 screws (D). (This makes it easy to adjust the position of attach it to the metal bracket fixed on the Basic Shelf, and slide it backwards until it locks. Metal Bracket 1 2 Installation Manual 87
  • Panasonic KX-TDA600 | Installation Manual - Page 88
    2.2 Installation of the Hybrid IP-PBX 5. Secure Expansion Shelf 1 to the metal bracket with 2 screws (B). Screw (B) 88 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 89
    of the Hybrid IP-PBX Fixing to the Wall 1. Install 4 anchor plugs in the wall, using the wall brackets as a template. Fix the wall brackets to the wall with 4 in) Hammer Anchor Plug 8 mm (5/16 in) 30 mm (1-3/16 in) Screw (A) Washer Wall Bracket 892 mm (35-1/8 in) Installation Manual 89
  • Panasonic KX-TDA600 | Installation Manual - Page 90
    2.2 Installation of the Hybrid IP-PBX 2. Check that the shelves are standing exactly vertically. If the Stand Floor 95 mm (3-3/4 in) 382 mm (15-1/16 in) Installation of the first 2 shelves is complete. Next, install Expansion Shelves 2 and 3 next to the Basic Shelf and Expansion Shelf 1. 90
  • Panasonic KX-TDA600 | Installation Manual - Page 91
    of the Hybrid IP-PBX Installing Expansion Shelves 2 and 3 Repeat the procedure in "Installing the Basic Shelf and Expansion Shelf 1" for Expansion Shelves 2 and 3. Expansion Shelves 2 and 3 must be connected to the Basic Shelf using Bus Cables. Therefore, make
  • Panasonic KX-TDA600 | Installation Manual - Page 92
    2.2 Installation of the Hybrid IP-PBX Connecting Shelves For the 4-shelf system, you need to install an optional BUS about the cards, refer to "2.4.1 BUS-M Card (KX-TDA6110)", "2.4.2 BUS-ME Card (KXTDA6111)", and "2.5.1 BUS-S Card". Note When installing or removing the BUS-M card, make sure that the
  • Panasonic KX-TDA600 | Installation Manual - Page 93
    2.2 Installation of the Hybrid IP-PBX 2. Insert the BUS-M card along the guide rails in the BUS-M Card Slot (the right-most slot) of the Basic Shelf. Guide Rail 3. Push the release lever in the direction of the arrow so that the BUS-M card engages securely with the connector on the back board.
  • Panasonic KX-TDA600 | Installation Manual - Page 94
    Hybrid IP-PBX 5. Plug each Bus Cable into the corresponding port of the BUS-M card in the Basic Shelf. Then, plug the other end into the BUS-S card in each Expansion Shelf. Note When plugging or unplugging the Bus Cables, make sure that the DC power supply is turned off. Bus Cable 94 Installation
  • Panasonic KX-TDA600 | Installation Manual - Page 95
    the Hybrid IP-PBX 6. Attach the noise shield wires of each Bus Cable to the Basic Shelf and each Expansion Shelf with the screws of the BUS-M card. Note When attaching or removing the noise shield wires, make sure that the DC power supply is turned off. Screw Noise Shield Wire Installation Manual 95
  • Panasonic KX-TDA600 | Installation Manual - Page 96
    2.2 Installation of the Hybrid IP-PBX 2.2.8 Wall Mounting (KX-TDA600/KX-TDA620) Mounting Shelves CAUTION • Make sure that the wall the shelves will be attached to is capable of supporting at least 4 times the weight of the shelves. • Drive mounting screws into the wall. Be careful to avoid
  • Panasonic KX-TDA600 | Installation Manual - Page 97
    of the Hybrid IP-PBX 2. Hook the shelf onto the metal bracket, making sure that the shelf slides down and onto the hooked parts of the metal bracket. Use 2 screws (B) to fix both sides of the shelf. TOP Screw (B) Connecting Shelves For a multiple shelf system, you need to install an optional
  • Panasonic KX-TDA600 | Installation Manual - Page 98
    of the Hybrid IP-PBX 2.2.9 Installing/Replacing the Power Supply Unit Function PSU Type PSU-M PSU-L power cord × 1 User-supplied (not included): Grounding wire Note For details about frame ground connection, refer to "2.2.10 Frame Ground Connection". Safety Instructions Each PSU complies with
  • Panasonic KX-TDA600 | Installation Manual - Page 99
    of the Hybrid IP-PBX 4. To protect the back board from static electricity, do not touch parts on the back board in the main unit and PSU. To discharge static electricity, touch ground or wear a grounding strap. The following procedures are for installing or replacing a PSU only. Do not replace
  • Panasonic KX-TDA600 | Installation Manual - Page 100
    2.2 Installation of the Hybrid IP-PBX 2. Push the release lever in the direction of the arrow, so that the PSU engages securely with the connector on the back board by the numbers 1 to 4, to fix the PSU. 32 Screws 41 Replacing the Power Supply Unit 1. Unplug the AC power cord. 100 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 101
    2. Turn the 4 screws counterclockwise to loosen them. 2.2 Installation of the Hybrid IP-PBX Screws 3. Pull the release lever in the direction of the arrow to disconnect the PSU from the back board. Back Board Release Lever 4. Replace the
  • Panasonic KX-TDA600 | Installation Manual - Page 102
    local regulations (e.g., laws, guidelines). • Proper grounding (connection to ground) is very important to protect the Hybrid IP-PBX from the bad effects of external noise or to reduce the risk to the user of electrocution in the case of a lightning strike. • The grounding wire of the AC cable has
  • Panasonic KX-TDA600 | Installation Manual - Page 103
    service cards can be installed or removed while the DC power is supplied. However, when installing or removing the EMPR card, BUS-M card or BUS-S card, the DC power supply must be turned off. Installing Optional Service Cards 1. Insert the card along the guide rails. Guide Rail Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 104
    2.2 Installation of the Hybrid IP-PBX 2. Holding the card as shown below, push the release lever in the direction of the arrow so that the card engages 2 screws clockwise to fix the card in place. Screws Note Make sure the screws are tightened to ground the card securely. 104 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 105
    2.2 Installation of the Hybrid IP-PBX Covering the Blank Slots Be sure to cover each slot in which no optional service card is installed by using a Blank Slot Cover. CAUTION Failure to install the Blank Slot Cover may cause electromagnetic interference. Installation Manual 105
  • Panasonic KX-TDA600 | Installation Manual - Page 106
    the Hybrid IP-PBX Removing the Optional Service Cards 1. Turn the 2 screws counterclockwise to loosen them. Screws 2. Pull the release lever in the direction of the arrow to disconnect the card from the back board. Pull the card from the shelf to remove it. Back Board Release Lever 106 Installation
  • Panasonic KX-TDA600 | Installation Manual - Page 107
    2.2 Installation of the Hybrid IP-PBX 2.2.12 Cable Handling Note For safety reasons, do not stretch, bend, or pinch the AC power cord. Cable Handling for Each Shelf When cables are
  • Panasonic KX-TDA600 | Installation Manual - Page 108
    2.2 Installation of the Hybrid IP-PBX Cable Handling for Connected Shelves When running connected cables towards the back of the shelves, make sure not to block the opening of each Fan Guard as shown below. Fan Guard 108 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 109
    ) • IP-GW16 (KX-TDA0490) • DHLC8 (KX-TDA0170) • DLC8 (KX-TDA0171) • DLC16 (KX-TDA0172) • SLC8 (KX-TDA0173) • ESLC16 (KX-TDA6174) • EMSLC16 (KX-TDA6175) • ELCOT16 (KX-TDA6181) 1 1 • DPH4 (KX-TDA0161) • EIO4 (KX-TDA0164) RS-232C 10 8 6 1 • Basic Shelf (KX-TDA600) 9 5 Installation Manual 109
  • Panasonic KX-TDA600 | Installation Manual - Page 110
    2.2 Installation of the Hybrid IP-PBX Connector Type USB Pin Number • EMPR 3 2 4 1 Mini Plug • EMPR 2 4 Used for 110 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 111
    2.2 Installation of the Hybrid IP-PBX 2.2.14 Attaching a Ferrite Core A ferrite core must be attached when: • connecting IP-GW16 and IP-EXT16 cards using an RJ45 connector, or • connecting extension cards using an Amphenol connector. The ferrite core is included with the card. When connecting an IP-
  • Panasonic KX-TDA600 | Installation Manual - Page 112
    2.2 Installation of the Hybrid IP-PBX If you need to open the ferrite core, use a flathead screwdriver to unlatch the case of the ferrite core. 112 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 113
    2.2 Installation of the Hybrid IP-PBX 2.2.15 Fastening Amphenol Connector An Amphenol 57JE-type connector is used on some of the optional service cards. To connect an Amphenol connector, use the spring latch or screw to fix the upper part and use Velcro® tape to fix the lower
  • Panasonic KX-TDA600 | Installation Manual - Page 114
    2.2 Installation of the Hybrid IP-PBX Amphenol Connector Pin Assignment Chart Below is an Amphenol connector pin assignment chart for all optional service cards that use the Amphenol connector. For more details, refer to the appropriate section in "2.6 Information about the CO Line Cards" and "2.7
  • Panasonic KX-TDA600 | Installation Manual - Page 115
    the building via the CO line and damaging the Hybrid IP-PBX and connected equipment. To protect the system from electrical surges, we strongly recommend connecting the system to a surge protector that meets the following specifications: - Surge arrestor type: 3-electrode arrestor - DC spark-over
  • Panasonic KX-TDA600 | Installation Manual - Page 116
    (Main Building) Surge Protector CO Line CO Line Terminal Board Extn. Hybrid IP-PBX Extn. Extn. (Another Building) SLT Extn. PT Surge CS Protector SLT PT CS Ground Extn.: Extension Line If you install an extension outside of the building, the following precautions are recommended
  • Panasonic KX-TDA600 | Installation Manual - Page 117
    2.2 Installation of the Hybrid IP-PBX 1. Connect the grounding rod to the surge protector using a grounding wire with a cross-sectional area of at least 1.3 are recommendations only. The length of grounding rod and the required depth depend on the composition of the soil. Installation Manual 117
  • Panasonic KX-TDA600 | Installation Manual - Page 118
    the Reset Button". CAUTION • Use only the SD Memory Card included with the Hybrid IP-PBX, or a Panasonic optional upgrade SD Memory Card. • The SD Memory Card contains software for all the processes of the Hybrid IP-PBX and all the customer data. The SD Memory Card must be inserted before startup
  • Panasonic KX-TDA600 | Installation Manual - Page 119
    REPLACED WITH THE INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. LED Indications Indication BATT ALARM Color Red SD ACCESS Green Description Battery alarm indication • OFF: Normal ON: Alarm SD memory card status • ON: Accessing Installation Manual 119
  • Panasonic KX-TDA600 | Installation Manual - Page 120
    Function Memory expansion card to increase system data storage space and double the number of PSs. To be mounted on the EMPR card. EMPR Card inside EMEC Card Screw Accessories and User-supplied Items Accessories (included): Screws × 2 User-supplied (not included): none 120 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 121
    (KX-TDA0196) Function Analog modem card for remote communication with the Hybrid IP-PBX. V90 support. To be mounted on the EMPR card. EMPR Card inside RMT Card Screw Accessories and User-supplied Items Accessories (included): Screws × 2 User-supplied (not included): none Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 122
    KX-TDA6110) Function Optional shelf expansion card required when mounting Expansion Shelves. To be installed in the Basic Shelf only. LEDs Bus Cable Connector Noise Shield Connector Accessories and User-supplied Items Accessories (included): Bus Cable × 1 User 122 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 123
    card required when mounting Expansion Shelf 2 or 3. To be mounted on the BUSM card installed in the Basic Shelf. BUS-M Card inside BUS-ME Card Screw Accessories and User-supplied Items Accessories (included): Bus Cable × 1, Screws × 2 User-supplied (not included): none Installation Manual 123
  • Panasonic KX-TDA600 | Installation Manual - Page 124
    . DISPOSE OF USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. LED Indications Indication CARD STATUS Color Green/Red Description Card status indication • Green ON: Normal • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service 124 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 125
    card (refer to "2.6.2 CID8 Card (KX-TDA0193)"). LED Amphenol To CO line Accessories and User-supplied Items Accessories (included): Screws × 2 User-supplied (not included): Amphenol connector Notes the CO Line Connection" in "2.14.1 Starting the Hybrid IP-PBX". Installation Manual 125
  • Panasonic KX-TDA600 | Installation Manual - Page 126
    idle) • Green Flashing (60 times per minute): Normal (a port is in use) • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service 126 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 127
    supplied Items Accessories (included): Screws × 2 User-supplied (not included): none Switch Settings (on ELCOT16 card) Switch Port Setting Type DIP Usage and Status Definition Keep all DIP switches at default "ON" positions. Do not change the positions of these switches. Installation Manual 127
  • Panasonic KX-TDA600 | Installation Manual - Page 128
    " in "2.14.1 Starting the Hybrid IP-PBX". CAUTION T1 ports are SELV ports and should only be connected to SELV services. Switch Settings Switch A/B Type Slide Usage and Status Definition Keep the switch at default A position. Do not change the position of this switch. 128 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 129
    ) • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service Non-synchronization status indication • OFF: Normal • ON: Out of synchronization RAI signal status indication • Synchronized • Flashing (60 times per minute): Synchronized (Clock Master) Installation Manual 129
  • Panasonic KX-TDA600 | Installation Manual - Page 130
    " in "2.14.1 Starting the Hybrid IP-PBX". CAUTION PRI ports are SELV ports and should only be connected to SELV services. Switch Settings Switch A/B Type Slide Usage and Status Definition Keep the switch at default A position. Do not change the position of this switch. 130 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 131
    use) • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service Non-synchronization status indication • OFF: Normal • ON: Out of synchronization RAI signal status indication • OFF Data link status indication • OFF: Not established • ON: Established Installation Manual 131
  • Panasonic KX-TDA600 | Installation Manual - Page 132
    × 1 User-supplied (not included): RJ45 connector Notes • • • • The maximum length of the cable to be connected to this optional service card is 100 m (328 ft). The IP-GW4E card occupies the space of only 1 free slot when it is installed in the Hybrid IP-PBX. For programming instructions and other
  • Panasonic KX-TDA600 | Installation Manual - Page 133
    reset) • Red Flashing (60 times per minute): Out of Service On-line status indication • ON: On-line mode • OFF: Off-line mode • Flashing: Maintenance mode Note If the LINK indicator is OFF, the ONLINE transmission indication • OFF: No data transmitted • ON: Data transmitting Installation Manual 133
  • Panasonic KX-TDA600 | Installation Manual - Page 134
    card, refer to the documentation for the IP-GW16 card. To program the IP-GW16 card, use the web programming designed for the IP-GW16 card. To confirm the CO line connection, refer to "Confirming the CO Line Connection" in "2.14.1 Starting the Hybrid IP-PBX". Pin Assignments RJ45 Connector (10BASE
  • Panasonic KX-TDA600 | Installation Manual - Page 135
    reset) • Red Flashing (60 times per minute): Out of Service On-line status indication • ON: On-line mode • OFF: Off-line mode • Flashing: Maintenance mode Note If the LINK indicator is OFF, the ONLINE transmission indication • OFF: No data transmitted • ON: Data transmitting Installation Manual 135
  • Panasonic KX-TDA600 | Installation Manual - Page 136
    CSIF8 card only. When using the CSIF4 card, please note that the Hybrid IP-PBX software will recognize the CSIF4 card as the CSIF8 card. As a result, 8 cell stations may appear to be available; however, only 4 cell stations are supported by the CSIF4 card. For details about connecting the CS, refer
  • Panasonic KX-TDA600 | Installation Manual - Page 137
    2.7 Information about the Extension Cards Editing the CS Name using the KX-TDA600 Maintenance Console While programming the Hybrid IP-PBX, we strongly recommend that you input a unique recognizable CS name (maximum 20 characters) for each CS port in use, and "(Reserved)" or "(Not for CSIF4)"
  • Panasonic KX-TDA600 | Installation Manual - Page 138
    idle) • Green Flashing (60 times per minute): Normal (a port is in use) • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service 138 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 139
    KX-TDA0170) Function 8-port digital hybrid extension card for DPTs, APTs, SLTs, DSS consoles, and PT-interface CSs, with 2 power failure transfer (PFT) ports. LED Amphenol To extensions Accessories and User failure transfer, refer to "2.13.1 Power Failure Connections". Installation Manual 139
  • Panasonic KX-TDA600 | Installation Manual - Page 140
    Tip port 7 45 D1G PT Data port 7 (High) 46 Reserved - 47 TH SLT Tip port 8 48 D1H PT Data port 8 (High) 49- Reserved - 50 140 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 141
    of PT-interface CS connection (when starting up the PT-interface CS) • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service Installation Manual 141
  • Panasonic KX-TDA600 | Installation Manual - Page 142
    (included): Screws × 2, Ferrite core × 1 User-supplied (not included): Amphenol connector Notes • • Attach the included ferrite core to the cable. Refer to "2.2.14 Attaching a Ferrite Core". To connect the Amphenol connector, refer to "2.2.15 Fastening Amphenol Connector". 142 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 143
    of PT-interface CS connection (when starting up the PT-interface CS) • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service Installation Manual 143
  • Panasonic KX-TDA600 | Installation Manual - Page 144
    (included): Screws × 2, Ferrite core × 1 User-supplied (not included): Amphenol connector Notes • • Attach the included ferrite core to the cable. Refer to "2.2.14 Attaching a Ferrite Core". To connect the Amphenol connector, refer to "2.2.15 Fastening Amphenol Connector". 144 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 145
    of PT-interface CS connection (when starting up the PT-interface CS) • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service Installation Manual 145
  • Panasonic KX-TDA600 | Installation Manual - Page 146
    KX-TDA0173) Function 8-port extension card for SLTs with 2 power failure transfer (PFT) ports. LED Amphenol To extensions Accessories and User-supplied Items Accessories (included): Screws × 2, Ferrite core × 1 User transfer, refer to "2.13.1 Power Failure Connections". 146 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 147
    idle) • Green Flashing (60 times per minute): Normal (a port is in use) • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service Installation Manual 147
  • Panasonic KX-TDA600 | Installation Manual - Page 148
    Cards 2.7.6 EXT-CID Card (KX-TDA0168) Function Sends Caller ID signals to extension ports. To be mounted on the SLC8 card only. SLC8 Card inside Screw EXT-CID Card Accessories and User-supplied Items Accessories (included): Screws × 2 User-supplied (not included): none 148 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 149
    User-supplied Items Accessories (included): Screws × 2, Ferrite core × 1 User-supplied (not included): Amphenol connector Notes • • • • Panasonic SLT with Message Waiting Lamp (e.g., KX- For details about power failure transfer, refer to "2.13.1 Power Failure Connections". Installation Manual 149
  • Panasonic KX-TDA600 | Installation Manual - Page 150
    idle) • Green Flashing (60 times per minute): Normal (a port is in use) • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service 150 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 151
    IP-EXT16 Card (KX-TDA0470) Function 16-channel VoIP extension card. Compliant with Panasonic proprietary protocol, and ITU-T G.729a and G.711 CODEC methods. LEDs RJ45 (10BASE-T/100BASE-TX Full Duplex) To private IP network Accessories and User data+ - Receive data- Installation Manual 151
  • Panasonic KX-TDA600 | Installation Manual - Page 152
    • ON: Alarm Panasonic proprietary VoIP protocol process indication • OFF: VoIP process inactive • ON: VoIP process active Link status indication • OFF: Connection error • ON: Normal connection Data transmission indication • OFF: No data transmitted • ON: Data transmitting 152 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 153
    User-supplied (not included): none CAUTION A LITHIUM BATTERY IS USED IN OPB3 CARD. THERE IS A RISK OF EXPLOSION IF THE BATTERY IS REPLACED WITH THE INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS (60 times per minute): Out of Service Installation Manual 153
  • Panasonic KX-TDA600 | Installation Manual - Page 154
    ): Screws × 3, 10-pin terminal block × 1, 8-pin terminal block × 1 User-supplied (not included): Copper wire Note For details about connection to doorphones and door openers, refer to "2.11.1 Connection of Doorphones, Door Openers, External Sensors, and External Relays". 154 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 155
    Doorphone 1 transmit Doorphone 1 receive Function - Door opener 4 Door opener 4 com Door opener 3 Door opener 3 com Door opener 2 Door opener 2 com Door opener 1 Door opener 1 com Installation Manual 155
  • Panasonic KX-TDA600 | Installation Manual - Page 156
    × 3, 10-pin terminal block × 1, 8-pin terminal block × 1 User-supplied (not included): Copper wire Note For details about connection to external sensors and external relays, refer to "2.11.1 Connection of Doorphones, Door Openers, External Sensors, and External Relays". 156 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 157
    Control 4 Control 4 com Control 3 Control 3 com Control 2 Control 2 com Control 1 Control 1 com Function - Opener 4 Opener 4 com Opener 3 Opener 3 com Opener 2 Opener 2 com Opener 1 Opener 1 com Installation Manual 157
  • Panasonic KX-TDA600 | Installation Manual - Page 158
    of "sensor" and "common" lines are connected to the EIO4 card for each external sensor. The Hybrid IP-PBX detects input from the sensor when the signal is under 100 Ω. Connection Diagram Hybrid IP-PBX OPB3 EIO4 +5V 10K I/O 4.7K 4.7K +5V 33 33 sensor common External Sensor External Relay Current
  • Panasonic KX-TDA600 | Installation Manual - Page 159
    2.8.4 MSG4 Card (KX-TDA0191) Function 4-channel message card. To be mounted on the OPB3 card. OPB3 Card MSG4 Card inside Screw 2.8 Information about the Other Cards Accessories and User-supplied Items Accessories (included): Screws × 3 User-supplied (not included): none Installation Manual 159
  • Panasonic KX-TDA600 | Installation Manual - Page 160
    call involving 6 to 8 parties, install an EECHO16 card and enable echo cancellation for conferences using the KX-TDA600 Maintenance Console. For details, refer to "Echo Cancel-Conference" in "2.8.17 [2-9] System Options" of the PC Programming Manual. LED Indications Indication CARD STATUS Color
  • Panasonic KX-TDA600 | Installation Manual - Page 161
    m (328 ft). This optional service card can be connected to PCs on a LAN via a CTI server to provide third party call control CTI. The operating system of the PC or CTI server required for third party call control depends on your CTI application software. For details, refer to the manual for your CTI
  • Panasonic KX-TDA600 | Installation Manual - Page 162
    STATUS Green Description Card status indication • OFF: Power Off • Green ON: Normal • Red ON: Fault (includes reset) • Red Flashing (60 times per minute): Out of Service Link status indication • Flashing: In communication • ON: Linked normally 162 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 163
    : 1798 m (5897 ft) SLT CAT 5: 1128 m (3700 ft) * The maximum cabling distance from the Hybrid IP-PBX is the same even when the KX-T7600 series DPT is the master DPT on the Digital XDP connection. Notice The maximum cabling distance may vary depending on the conditions. Installation Manual 163
  • Panasonic KX-TDA600 | Installation Manual - Page 164
    2.9 Connection of Extensions DHLC8 Card PT-interface CS EMSLC16, ESLC16, SLC8 Cards DLC16, DLC8 Cards DPT APT DSS Console SLT " " indicates that the extension card supports the terminal. 164 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 165
    a modem (PC) can be connected in parallel with an APT or a DPT. With APT For parallel connection, eXtra Device Port (XDP) mode must be disabled for that port through system programming. Refer to "1.13.2 Paralleled Telephone" and "1.5.7 Extension Port Configuration" in the Feature Manual for further
  • Panasonic KX-TDA600 | Installation Manual - Page 166
    (XDP) mode can be selected through system programming. If XDP mode is enabled through system programming, parallel connection is not possible. Refer to "1.13.2 Paralleled Telephone" and "1.5.7 Extension Port Configuration" in the Feature Manual for further information. Using a Modular T-Adaptor
  • Panasonic KX-TDA600 | Installation Manual - Page 167
    With Other DPT To DHLC8 card 4-conductor wiring cord Connect pins "T", "R", "D1" and "D2". 2.9 Connection of Extensions 2-conductor wiring cord Connect pins "T" and "R". DPT SLT TO EMSS or TO MAIN UNIT To DHLC8 card TO TEL To SLT Installation Manual 167
  • Panasonic KX-TDA600 | Installation Manual - Page 168
    XDP mode can be selected through system programming. If XDP mode is enabled through system programming, parallel connection is not possible. Refer to "1.13.2 Paralleled Telephone" and "1.5.7 Extension Port Configuration" in the Feature Manual for further information. With KX-T7600 Series DPT Using
  • Panasonic KX-TDA600 | Installation Manual - Page 169
    Maximum Distance 26 AWG: 30 m (98 ft) 24 AWG: 50 m (164 ft) 22 AWG: 60 m (196 ft) CAT 5: 50 m (164 ft) SLT TO MAIN UNIT / PABX TO MAIN UNIT / PABX Master DPT To DLC8/DLC16 card To SLT To DHLC8 card (for connection of SLT) Slave DPT TO TEL Installation Manual 169
  • Panasonic KX-TDA600 | Installation Manual - Page 170
    made via a USB interface (version 2.0), and uses the TAPI 2.1 protocol. A USB Module (KX-T7601) must be connected to the KX-T7633/T7636 DPT. Note The operating system of the PC required for first party call control depends on your CTI application software. For details, refer to the manual for your
  • Panasonic KX-TDA600 | Installation Manual - Page 171
    GHz Portable Station (KX-TD7680/KX-TD7690) The Hybrid IP-PBX can support up to 256 PSs. If an EMEC card is installed in the Hybrid IP-PBX, up to 512 PSs can be supported. For more details about the PS, refer to the PS Operating Instructions. CAUTION • The CS should be kept free of dust, moisture
  • Panasonic KX-TDA600 | Installation Manual - Page 172
    . Please consult a certified dealer for details. However, the required distance between CSs may vary depending on the environment of the installation site and conditions in which the wireless system is used. Conduct the site survey to determine the appropriate distance. 172 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 173
    signal strength level is "12" near the CS. Using the KX-TD7680 19 0 Press 1, 9, and POWER for more than 2 seconds. Using the KX-TD7690 CS No. 1 to 9 Display example: > level is greater than "3" at any location within the service area required by the user. Installation Manual 173
  • Panasonic KX-TDA600 | Installation Manual - Page 174
    to the Hybrid IP-PBX. c. Walk around the service area while having a conversation using a registered PS. If noise is frequent or conversations disconnect, relocate the CSs or install an additional CS. 6. Mount the CS on the wall Refer to "2.10.8 Wall Mounting". a. If there are no problems in testing
  • Panasonic KX-TDA600 | Installation Manual - Page 175
    essential areas. The best location may not always be convenient for installation. Read the following information before installing the unit. Understanding Radio Waves Characteristics of Radio Waves The of radio waves when they reach objects made from various materials. Installation Manual 175
  • Panasonic KX-TDA600 | Installation Manual - Page 176
    be reflected. Glass covered with Radio waves are weakened considerably when they heat-resistant film penetrate windows. Ferroconcrete Radio waves can penetrate them, but the more iron there is, the more radio . Wood Radio waves can penetrate them, but they are weakened. 176 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 177
    a CS cannot be installed outside a building. b. If one CS cannot cover the entire service area, install additional CSs as required. Overlap the coverage areas of adjacent CSs. Where CS coverage areas overlap, the PS will start call handover to the next CS if the signal from Installation Manual 177
  • Panasonic KX-TDA600 | Installation Manual - Page 178
    may be some handover delay. The user will hear a range warning before handover in this case. This also applies in the case of interference from 2.4 GHz apparatus. Example: Installing in a Room Separated by Interior Walls ft) CS no. 1 CS no. 3 CS no. 5 CS no. 2 CS no. 4 178 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 179
    Switch OFF ON 1 2 CS Number Switch 3 4 Keep this switch at the default 5 "OFF" position. Otherwise, the CS will not function. 6 Radio Signal Test 3 4 4 4 4 4 4 4 4 4 Note If more than 1 CS is in Radio Signal Test mode, each CS must have a unique CS number. Installation Manual 179
  • Panasonic KX-TDA600 | Installation Manual - Page 180
    may cause it to become disconnected. Modular Telephone Cord Power Supply Adaptor (PSZZ1TDA0142) To AC Adaptor (KX-A11/KX-TCA1)/ Battery Box (PSZZTD142CE) 4. Install the CS temporarily for the site survey. Install the CS at least 2 m (6 ft 7 in) above the floor, keeping the antennas in the upright
  • Panasonic KX-TDA600 | Installation Manual - Page 181
    Note Display prompts for the site survey are only available in English. 1. Enter Radio Signal Test mode. Using the KX-TD7680 19 0 Press 1, 9, and POWER for more than 2 seconds. To store the scan data Scan Data by a number; stored memory space will be indicated by a "-". Installation Manual 181
  • Panasonic KX-TDA600 | Installation Manual - Page 182
    radio signal strength level is "8" by 5 to 10 meters (16 to 33 feet). CS no. 1 5 m to 10 m (16 ft to 33 ft) CS no. 2 182 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 183
    CSs at any location in the installation site. CS no. 1 CS no. 2 CS no. 3 CS no. 4 c. Make sure that the radio signal strength level is greater than "3" at any location in the service area required by the user. Referring to the Stored Scan Data Using the KX-TD7680 19 Press 1, 9, and POWER for
  • Panasonic KX-TDA600 | Installation Manual - Page 184
    TD7680 19 Press 1, 9, and POWER for more than 2 seconds. 2 Scan Data No. 0 to 9, or # for all data To the Desired Scan Data No. Using the KX-TD7690 19 2 Press 1, 9, and POWER for more than 2 seconds. Scan Data No. 0 to 9, or # for all data To the Desired Scan Data No. 184 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 185
    GHz Portable Stations 2.10.6 After Site Survey After obtaining the proper measurement results, exit Radio Signal Test mode before connecting the CS to the Hybrid IP-PBX. 1. Keep pressing the POWER button on the PS until the PS is turned OFF. 2. Disconnect the AC adaptor or battery box from the CS
  • Panasonic KX-TDA600 | Installation Manual - Page 186
    8 Signal Name D1 POWH POWL D2 Accessories and User-supplied Items for the CS Accessories (included): Screws × 2, Washers × 2 User-supplied (not included): RJ11 connector Note For details about CSIF card, refer to "2.7.1 CSIF4 Card (KX-TDA0143) and CSIF8 Card (KXTDA0144)". 186 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 187
    User-supplied Items for the CS Accessories (included): Screws × 2, Washers × 2 User-supplied (not included): RJ11 connector Note For details about DHLC card or DLC card, refer to "2.7.2 DHLC8 Card (KX-TDA0170)", "2.7.3 DLC8 Card (KX-TDA0171)", or "2.7.4 DLC16 Card (KX-TDA0172)". Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 188
    . Modular To CSIF/DHLC/DLC card 2. Pass the cable through the groove of the CS (in any direction depending on your preference). TO MAIN UNIT / PABX To CSIF/DHLC/DLC card 188 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 189
    Hybrid IP-PBX system programming. Note For details about system programming using a PT, refer to "1.13.28 PT Programming" in the Feature Manual, and "2.1 PT Programming" in the PT Programming Manual. Entering the System Programming Mode PT (Administrator Level) PROGRAM/ PAUSE # System Password
  • Panasonic KX-TDA600 | Installation Manual - Page 190
    been registered to another Hybrid IP-PBX One PS can be registered to a maximum of 4 different Hybrid IP-PBXs. Using the KX-TD7680 Select "REGISTRATION". Using the KX-TD7690 SEL Select "REGISTRATION". S1 Choose "SYSTEM 1-4". C.Tone Choose "SYSTEM 1-4". SEL C.Tone S1 190 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 191
    Password ENABLE DISABLE 4 digits System Lock Password 4 digits C.Tone Using the KX-TD7690 SEL CHNG Select S1 "SYSTEM LOCK". S1 Choose "Enable/Disable". SEL ENTR System Lock Password ENABLE S1 DISABLE 4 digits S1 ENTR C.Tone S1 System Lock Password 4 digits Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 192
    for PS registration can be set to the Hybrid IP-PBX. Before registering the PS to the Hybrid IP-PBX, enter the PIN set to the Hybrid IP-PBX into the PS. By doing so, the PS will only be registered to the Hybrid IP-PBX with the matching PIN. Notes • By default, the PIN for PS registration is "1234
  • Panasonic KX-TDA600 | Installation Manual - Page 193
    DELETE SYSTEM". S1 Select the desired item. S1 Select "YES". SEL C.Tone S1 Testing the Operation Walk around the service area while having a conversation using a registered PS. If noise is frequent or conversations disconnect, relocate the CSs or install an additional CS. Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 194
    of 2.4 GHz Portable Stations 2.10.8 Wall Mounting 1. Place the reference for wall mounting (on the following page) on the wall to mark the 2 screw positions. 2. Install the 2 screws and washers (included) into the wall. Notes • Make sure that the screw heads are at the same distance from the wall
  • Panasonic KX-TDA600 | Installation Manual - Page 195
    2.10 Connection of 2.4 GHz Portable Stations Reference for Wall Mounting Please copy this page and use as a reference for wall mounting. Install a screw here. 71 mm (2-13/16 in) Install a screw here. Note Make sure to set the print size to correspond with the size of this page. If the dimension of
  • Panasonic KX-TDA600 | Installation Manual - Page 196
    Openers, External Sensors, and External Relays The Hybrid IP-PBX supports a maximum of 64 doorphones, 64 door openers External Sensor/ External Relay Device Installing the Doorphone (KX-T30865) 1. Loosen the screw to separate the doorphone into 2 halves. Panasonic Screw 196 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 197
    hole as shown below. Repeat this procedure for other doorphones, door openers, external sensors, and external relays. Refer to "2.8.2 DPH4 Card (KX-TDA0161)" and "2.8.3 EIO4 Card (KX-TDA0164)" for pin assignments. Doorphone Door Opener External Sensor/ External Relay Device Installation Manual 197
  • Panasonic KX-TDA600 | Installation Manual - Page 198
    2.11 Connection of Doorphones, Door Openers, External Sensors, and External Relays 2. Attach the terminal blocks to the connectors of the DPH4/EIO4 card on the Hybrid IP-PBX. To doorphones/ door openers/ external sensors/ external relays 198 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 199
    PC Printer Maximum Distance 2 m (6 ft) USB RS-232C BGM/MOH The Hybrid IP-PBX provides Background Music and Music on Hold. Up to 2 external music sources (e.g., user-supplied radios) can be connected to the Hybrid IP-PBX SELV devices. Note When the Hybrid IP-PBX and external music sources are not
  • Panasonic KX-TDA600 | Installation Manual - Page 200
    -PBX and the user-supplied devices such as PC or line printers. The RS-232C port is used for system programming, SMDR, diagnostics and external system database storage (save/load) functions. When using special accessories such as cable, the user should use those specified in this installation manual
  • Panasonic KX-TDA600 | Installation Manual - Page 201
    PC with a 25-pin RS-232C connector Hybrid IP-PBX (9-pin) Printer/PC PC. • Transmit Data (TXD):...(output) Conveys signals from the unit to the printer or the PC the printer or the PC. It is switched PC is ready. Circuit DR (DSR) or the PC. • the printer or the PC is ready to receive
  • Panasonic KX-TDA600 | Installation Manual - Page 202
    Connection of Peripherals PC/CTI Server (via USB version 2.0) The Hybrid IP-PBX is equipped with a USB interface. This interface provides communication between the Hybrid IP-PBX and a PC or a CTI server. The PC is used for system programming, diagnostics and external system database storage (save
  • Panasonic KX-TDA600 | Installation Manual - Page 203
    power supply to the Hybrid IP-PBX fails, power failure transfer (PFT) will switch from the current connection to the Power Failure Connection. Refer to "1.13.9 Power Failure Transfer" in the Feature Manual for further information. Connection Power Failure Connection connects a specific SLT and a CO
  • Panasonic KX-TDA600 | Installation Manual - Page 204
    Ports 3 and 4 (for EMSLC16/ESLC16 card only) No. 1 12 4 3 4 Signal Name T4 T3 R3 R4 Function Tip port 4 Tip port 3 Ring port 3 Ring port 4 204 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 205
    the System Initialize Switch, discharge static electricity by touching ground or wearing a grounding strap. • Once you have started the Hybrid IP-PBX and if you unplug the Hybrid IP-PBX, do not perform the following procedures to start the Hybrid IP-PBX again. Otherwise, your programmed data
  • Panasonic KX-TDA600 | Installation Manual - Page 206
    with: • the System Initialize Switch in "SYSTEM INITIALIZE" position • the SD Memory Card not inserted Alarm indication • OFF: Normal • ON: Alarm (CPU stop, alarm for each optional service card installed in the Basic Shelf) • Flashing: Alarm (MPR file error in restarting) 206 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 207
    • OFF: Normal • ON: Alarm (CPU stop, alarm for each optional service card installed in Expansion Shelves) Confirming the CO Line Connection After initialization, program the Hybrid IP-PBX and connect CO lines to the Hybrid IP-PBX. To confirm that the CO lines are successfully connected, dial
  • Panasonic KX-TDA600 | Installation Manual - Page 208
    2.14 Starting the Hybrid IP-PBX 208 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 209
    Section 3 Guide for the KX-TDA600 Maintenance Console Explains the installation procedure, structure, and basic information of the KX-TDA600 Maintenance Console. Installation Manual 209
  • Panasonic KX-TDA600 | Installation Manual - Page 210
    overall system programming reference for the Hybrid IP-PBX. To program and administer the Hybrid IP-PBX by PC, you need to install the KX-TDA600 Maintenance Console onto the PC. This section describes overview and installation of the KX-TDA600 Maintenance Console only. KX-TDA600 Maintenance Console
  • Panasonic KX-TDA600 | Installation Manual - Page 211
    For pin assignments and maximum cabling distance, refer to "2.12.1 Connection of Peripherals". LAN Connection via CTI-LINK Card RJ45 Switching Hub To network port PC Note For pin assignments and maximum cabling distance, refer to "2.8.6 CTI-LINK Card (KX-TDA0410)". Installation Manual 211
  • Panasonic KX-TDA600 | Installation Manual - Page 212
    -PBX and external modem. An AT command (for initialization, enabling automatic answer, etc.) can only be programmed by KX-TDA600 Maintenance Console. "AT&F" is stored as the default value. For more information about the AT command, refer to the external modem's instructions. 212 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 213
    version of the KX-TDA600 Maintenance Console. To install or uninstall the software on a PC running Windows 2000 Professional or Windows XP Professional, you must be logged in as a user in either the "Administrators" or "Power Users" group. To connect the PC to the Hybrid IP-PBX via USB, the KX-TDA
  • Panasonic KX-TDA600 | Installation Manual - Page 214
    the Hybrid IP-PBX via USB, the KX-TDA USB driver must be installed on the PC, as explained above in "Installing the KX-TDA600 Maintenance Console". 6. Follow the instructions of the Quick Setup wizard and assign the basic items (Quick Setup). The system menu appears. You may now begin programming
  • Panasonic KX-TDA600 | Installation Manual - Page 215
    Installation of the KX-TDA600 Maintenance Console Notes • • During a long programming session, it is highly recommended that you periodically save the system data to the SD Memory Card. If the Hybrid IP-PBX undergoes a sudden power failure or if the system is reset for some reason, all the system
  • Panasonic KX-TDA600 | Installation Manual - Page 216
    3.3 Installation of the KX-TDA600 Maintenance Console 216 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 217
    Section 4 Troubleshooting This section provides information on the Hybrid IP-PBX and telephone troubleshooting. Installation Manual 217
  • Panasonic KX-TDA600 | Installation Manual - Page 218
    4.1 Troubleshooting 4.1 Troubleshooting 4.1.1 Installation PROBLEM Extension does not operate. PROBABLE CAUSE Bad extension card. • Bad connection between the • Hybrid IP-PBX and telephone. A telephone with an A-A1 relay • is connected. • Bad telephone. • Wrong type of PSU. • An
  • Panasonic KX-TDA600 | Installation Manual - Page 219
    See the error log using the KX-TDA600 Maintenance Console (refer to "4.1.5 Troubleshooting by Error Log"). Connect the Bus Cables properly. Replace the corresponding Bus Cable. Replace the corresponding shelf expansion card (be sure to turn off the Hybrid IP-PBX when replacing a BUSM card). Replace
  • Panasonic KX-TDA600 | Installation Manual - Page 220
    of the telephone to "OFF". Yes Connection between the Hybrid IP-PBX and an SLT that is polarity-sensitive: CAUSE The "T" is connected to the "R". D1 T T R R D2 Hybrid IP-PBX Extension SOLUTION Reverse the connections of the T/R. (Continued on the next page.) 220 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 221
    the Hybrid IP-PBX: CAUSE CO line is connected to the T2/T1. CO line T2 R1 T1 R2 Hybrid IP-PBX SOLUTION Reconnect the CO line to the T1/R1 or T2/R2 of the telephone jack using 2-conductor wiring. CO line is connected to the T2/R1. CO line T2 R1 T1 R2 Hybrid IP-PBX Installation Manual 221
  • Panasonic KX-TDA600 | Installation Manual - Page 222
    Troubleshooting 4.1.3 Operation PROBLEM Program the CO button. Refer to "1.6.3 call transfer, or conference button does not exist on the Flexible Buttons" in the Feature cannot be performed. PT. Manual. • Cannot register the PS. • Wrong Personal • Enter the PIN set to the Hybrid IP-PBX
  • Panasonic KX-TDA600 | Installation Manual - Page 223
    4.1 Troubleshooting PROBLEM • PS stays out of service when the CS status is changed from Out of Service to In Service. PROBABLE CAUSE SOLUTION • It may take about 20 s for • Wait until the CS starts up. CS to start up after the status has been changed to In Service. Installation Manual 223
  • Panasonic KX-TDA600 | Installation Manual - Page 224
    4.1 Troubleshooting 4.1.4 Using the Reset Button If the Hybrid IP-PBX does not operate properly, use the Reset Button. Before using the Reset Button, try the system feature again to confirm whether there definitely is a problem or not. CAUTION In order to avoid possible corruption of data on the
  • Panasonic KX-TDA600 | Installation Manual - Page 225
    system logs the error information. Error Log Display Format Below is the display format of the error log. For information about how to view the error log using the KXTDA600 Maintenance Console, refer to "2.5.8 Utility-Error Log" in the PC Programming Manual. Example: KX-TDA600 Maintenance Console
  • Panasonic KX-TDA600 | Installation Manual - Page 226
    4.1 Troubleshooting Item 5 Sub Code 6 Error Message 7 Log Information Description The 5- Slot; 01 to 10: Free Slots) - Expansion Shelf: 01 to 12 (01 to 11: Free Slots; 12: BUS-S Card Slot) • ZZ: Physical port number - For optional service cards except OPB3 card: Physical 226 Installation Manual
  • Panasonic KX-TDA600 | Installation Manual - Page 227
    Index Installation Manual 227
  • Panasonic KX-TDA600 | Installation Manual - Page 228
    software version of your Hybrid IP-PBX 12 DPH4 Card (KX-TDA0161) 154 Amphenol Connector 113, 114 E B Editing the CS Name using the KX-TDA600 Maintenance Console 137 Basic Shelf 22 EECHO16 Card (KX-TDA6166) 160 Basic Shelf, Construction 22 EIO4 Card (KX-TDA0164) 156 Basic Shelf, Installation
  • Panasonic KX-TDA600 | Installation Manual - Page 229
    31, 134 KX-TDA600 Maintenance Console, Connection 211 KX-TDA600 Maintenance Console, Installation 213 KX-TDA600 Maintenance Console, Overview 210 KX-TDA600 Maintenance Console, Password Security 10 KX-TDA600 Maintenance Console, Quick Setup 213 KX-TDA600 Maintenance Console, System Requirements 213
  • Panasonic KX-TDA600 | Installation Manual - Page 230
    32 Specifications, System Capacity 35 Starting the Hybrid IP-PBX 205 Supplied Items for an Expansion Shelf (KX-TDA620) 44 Supplied Items for the Basic Shelf (KX-TDA600) 44 Supplied Items for the Mounting Kit (KX-TDA6201) 45 Surge Protector Installation 115 System Capacity 35 System Components
  • Panasonic KX-TDA600 | Installation Manual - Page 231
    Index Installation Manual 231
  • Panasonic KX-TDA600 | Installation Manual - Page 232
    Puerto Rico, Inc. San Gabriel Industrial Park, Ave. 65 de Infantería, Km. 9.5, Carolina, Puerto Rico 00985 http://www.panasonic.com/csd Copyright: This material is copyrighted by Panasonic Communications Co., Ltd., and may be reproduced for internal use only. All other reproduction, in whole or in
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232

Model No.
KX-TDA600
Hybrid IP-PBX
Installation Manual
Thank you for purchasing a Panasonic Hybrid IP-PBX.
Please read this manual carefully before using this product and save this manual for future use.
KX-TDA600: PLMPR Software File Version 3.1000 or later
SD Logo is
a trademark.
Document Version: 2006-07