Panasonic MCV6603 MCV6603 User Guide - Page 34
REPLACING BRUSHES, Pull agitator shaft out of agitator
View all Panasonic MCV6603 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Replacing Brushes Card Carte Tarjeta ➢ When the bristles on the agitator are worn so that they do not touch a card held across the lower plate, the brushes should be replaced. ➢ Remove lower plate and agitator. E-Clip Bride en E Sujetador de E Agitator Shaft Arbre d'entraînement Eje del agitador Right End Cap Bouchon droit Tapa de extremo derecho ➢ Remove the E-clip from agitator shaft and end cap. ➢ Do not bend agitator shaft or lose Eclip. ➢ Pull agitator shaft out of agitator body. Agitator Holder Agitator Pulley Support de l'agitateur Poulie de l'agitateur Soporte del'agitador Polea para correa Push Off Pousser Empuje hacia Brush fuera Brosse Cepillo ➢ Pull, or pry out, agitator holder and agitator pulley. ➢ Push each brush out of agitator body as shown. ➢ Install new brushes by reversing procedure. ➢ Reinstall agitator holder and agitator pulley completely. ➢ Reinstall the agitator shaft, end cap and E-clip. ➢ See exploded view for correct assembly of parts. ➢ Position belt over agitator pulley on the agitator. ➢ Reinstall agitator and lower plate. - 34 -