MAINTENANCE AND TROUBLESHOOTING Inspect and properly tighten all parts of the recumbent cycle regularly. To clean the recumbent cycle, use a soft, damp cloth. To prevent damage to the console, keep liquids away from the console, keep the console out of direct sunlight, and remove the batteries when storing the recumbent cycle. BATTERY REPLACEMENT If the console display becomes dim, the batteries should be replaced. Refer to assembly step 3 on page 5 for replacement instructions. PULSE SENSOR TROUBLESHOOTING Avoid moving your hands while using the pulse sensor. Excessive movement may interfere with heart rate readings. Do not hold the metal contacts too tightly; doing so may interfere with heart rate readings. For the most accurate heart rate reading, hold the metal contacts for about 15 seconds. For optimal performance of the pulse sensor, keep the metal contacts clean. The contacts can be cleaned with a soft cloth-never use alcohol, abrasives, or chemicals. SEAT ADJUSTMENT TROUBLESHOOTING If the seat does not stay in place while you are pedaling, screw the Brake Pad (85) farther out of the Seat Adjustment Tab (79), down toward the Seat Rail (7). 79 85 7 HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, the Left Side Shield (4) must be removed. Using an adjustable wrench, turn the Left Pedal (69) clockwise and remove it. Next, remove the indicated Screws (64, 76). Turn the Left Crank Arm (51) so that it is pointing toward the front of the recumbent cycle and then slide off the Left Side Shield. 4 76 69 76 64 76 Next, locate the Reed Switch (61). Turn the Left Crank Arm (51) until the Magnet (59) is aligned with the Reed Switch. Loosen, but do not remove, the indicated Screw (64). Slide the Reed Switch slightly closer to or away from the Magnet. Retighten the Screw. Turn the Crank for a moment. Repeat until the console displays correct feedback. When the Reed Switch is correctly adjusted, reattach the left side shield and the left pedal. 59 64 51 61 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

16
Inspect and properly tighten all parts of the recumbent
cycle regularly. To clean the recumbent cycle, use a
soft, damp cloth.
To prevent damage to the console, keep liquids away
from the console, keep the console out of direct sun-
light, and remove the batteries when storing the
recumbent cycle.
BATTERY REPLACEMENT
If the console display becomes dim, the batteries
should be replaced. Refer to assembly step 3 on
page 5 for replacement instructions.
PULSE SENSOR TROUBLESHOOTING
Avoid moving your hands while using the pulse sen-
sor. Excessive movement may interfere with heart
rate readings. Do not hold the metal contacts too
tightly; doing so may interfere with heart rate read-
ings.
For the most accurate heart rate reading, hold the
metal contacts for about 15 seconds.
For optimal performance of the pulse sensor, keep the
metal contacts clean. The contacts can be cleaned
with a soft cloth—never use alcohol, abrasives, or
chemicals.
SEAT ADJUSTMENT TROUBLESHOOTING
If the seat does
not stay in place
while you are ped-
aling, screw the
Brake Pad (85)
farther out of the
Seat Adjustment
Tab (79), down
toward the Seat
Rail (7).
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, the Left Side Shield (4) must be removed.
Using an adjustable wrench, turn the Left Pedal (69)
clockwise and remove it. Next, remove the indicated
Screws (64, 76). Turn the Left Crank Arm (51) so that
it is pointing toward the front of the recumbent cycle
and then slide off the Left Side Shield.
Next, locate the Reed Switch (61). Turn the Left
Crank Arm (51) until the Magnet (59) is aligned with
the Reed Switch. Loosen, but do not remove, the indi-
cated Screw (64). Slide the Reed Switch slightly clos-
er to or away from the Magnet. Retighten the Screw.
Turn the Crank for a moment. Repeat until the con-
sole displays correct feedback. When the Reed
Switch is correctly adjusted, reattach the left side
shield and the left pedal.
MAINTENANCE AND TROUBLESHOOTING
85
79
7
64
76
76
4
76
64
69
61
51
59