Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit RAPMRev. 6/14/12 056JAZ 060JAZ Model Numbers Indoor Coil and/or Air Handler RCQD-6024(ROCA-070E04) RCQD-6024(ROLA-115E05) RCQD-6024+RXMD-C04 RHKL-HM6024(RCSL-H*6024) RHLL-HM6024(RCSL-H*6024) RCFL-H*6024+RXMD-C04 ➀ RCFL-A*6024(RGLT-10?BRM?) RCFL-A*6024(RGLT-12?ARM?) RCFL-A*6024(RGPT-07?BRQ?) RCFL-A*6024(RGPT-10?BRM?) RCFL-A*6024(RGPT-12?ARM?) RCFL-A*6024(RGTM-10?RBJ?) RCFL-A*6024+RXMD-C04 RCFL-H*6024(RGLT-10?BRM?) RCFL-H*6024(RGLT-12?ARM?) RCFL-H*6024(RGPT-07?BRQ?) RCFL-H*6024(RGPT-10?BRM?) RCFL-H*6024(RGPT-12?ARM?) RCFL-H*6024(RGTM-10?RBJ?) RBHP-25(RCHL-60A1) RBHM-26J(RCQD-6024) RCQD-6024(RGPE-10?BRM?) RCQD-6024(RGPE-12?ARM?) RCQD-6024(RGPT-07?BRQ?) RCQD-6024(RGPT-10?BRM?) RCQD-6024(RGPT-12?ARM?) RCQD-6024(RGTM-10?RBJ?) RCQD-6024+RXMD-C04 RHKL-HM6024(RCSL-H*6024) RHLL-HM6024(RCSL-H*6024) RHSL-HM6024(RCSL-H*6024) 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Total Net Net Capacity Sensible Latent EER BTU/H [kW] BTU/H [kW] BTU/H [kW] 48,500 [14.2] 32,050 [9.4] 16,450 [4.8] 11.50 49,000 [14.4] 32,400 [9.5] 16,600 [4.9] 11.50 49,000 [14.4] 34,050 [10.0] 14,950 [4.4] 11.00 54,000 [15.8] 39,100 [11.5] 14,900 [4.4] 13.00 54,000 [15.8] 38,670 [11.3] 15,330 [4.5] 13.00 60,500 [17.7] 41,500 [12.2] 19,000 [5.6] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 42,800 [12.5] 18,200 [5.3] 12.00 60,500 [17.7] 41,500 [12.2] 19,000 [5.6] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 43,000 [12.6] 18,000 [5.3] 12.00 61,000 [17.9] 42,800 [12.5] 18,200 [5.3] 12.00 54,000 [15.8] 35,850 [10.5] 18,150 [5.3] 11.50 60,000 [17.6] 42,500 [12.5] 17,500 [5.1] 12.50 59,000 [17.3] 40,500 [11.9] 18,500 [5.4] 11.50 59,000 [17.3] 40,500 [11.9] 18,500 [5.4] 11.50 59,500 [17.4] 42,000 [12.3] 17,500 [5.1] 11.50 59,500 [17.4] 42,000 [12.3] 17,500 [5.1] 11.50 59,500 [17.4] 42,000 [12.3] 17,500 [5.1] 11.50 59,000 [17.3] 41,500 [12.2] 17,500 [5.1] 11.50 58,500 [17.1] 40,000 [11.7] 18,500 [5.4] 11.50 62,000 [18.2] 45,000 [13.2] 17,000 [5.0] 12.50 62,000 [18.2] 45,000 [13.2] 17,000 [5.0] 12.50 60,500 [17.7] 43,500 [12.7] 17,000 [5.0] 11.50 ➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions SEER 13.50 14.00 13.50 16.00 16.00 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 14.50 13.50 15.00 14.00 14.00 14.00 14.00 14.00 14.00 13.50 15.00 15.00 13.50 Performance Data Air RAPM- JAZ Series Sound Rating dB 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 Indoor CFM [L/s] 1,400 [661] 1,400 [661] 1,600 [755] 1,600 [755] 1,550 [731] 1,600 [755] 1,700 [802] 1,700 [802] 1,700 [802] 1,700 [802] 1,700 [802] 1,675 [790] 1,600 [755] 1,700 [802] 1,700 [802] 1,700 [802] 1,700 [802] 1,700 [802] 1,675 [790] 1,800 [849] 1,700 [802] 1,625 [767] 1,625 [767] 1,725 [814] 1,725 [814] 1,725 [814] 1,675 [790] 1,600 [755] 1,800 [849] 1,800 [849] 1,800 [849] 31