Samsung DVE45T3400W/A3 User Manual - Page 25
STEP 3, Connect the electrical wiring - reviews
View all Samsung DVE45T3400W/A3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Installation STEP 3 Connect the electrical wiring First, read through the "Electrical requirements" section, and follow these steps. 3-wire system A B C L2 D L1 E 1. Loosen or remove the screws from the center terminal block. 2. Connect the neutral wire (white or center wire) of the power cable to the center, silver-colored terminal screw of the terminal block. Tighten the screws. 3. Connect the other wires to outer terminal block screws. Tighten the screws. 4. Tighten the strain relief screws. 5. Insert the terminal block cover into the rear panel of the dryer. Then, secure the cover with a hold-down screw. CAUTION A. External ground connector B. Neutral grounding wire (white) C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. 3/4" (1.9 cm) UL-listed strain relief • To convert from the 4-wire system to 3-wire system, connect the ground strap to the terminal block support to ground the dryer frame to the neutral conductor. • Ring-type terminals are recommended. If using strap terminals, make sure they are tightened. • Before Installing the Dryer, confirm 240 V is present between L1 and L2 at the power receptacle. If the Voltage is low, it may not dry properly. Review the "Electrical requirements" section on page 19 if needed. DV3400T_DC68-03784M-00_EN.indd 25 English 25 2020-06-11 10:01:21