Samsung NQ70T5511DG/AA Installation Guide - Page 6

Cabinet dimensions - Combi. ovens

Page 6 highlights

Preparation Preparation Cabinet dimensions - Combi. ovens Combi Ovens Installed in Cabinet 01 Junction Box 02 Allow a minimum of 22" for clearance to adjacent corners, drawers, walls, etc. when door is open A B 01 I J F D H Cabinet A B C D E F 6 English E 02 G 22" C DIMENSION 30" (76.2 cm) Min. 13/16" (3.0 cm) 12" (30.5 cm) Min. 281/2"/ Max. 285/8" (Min. 72.4 cm / Max. 72.7 cm) Min. 1"/ Max. 11/4" (Min. 2.5 cm / Max. 3.2 cm) 421/4" (107.2 cm) Cabinet G H I J DIMENSION Min. 231/2" (Min. 59.7 cm) Min 301/2" (Min 755 mm) Max. 91/2" (Max. 24.1 cm) - Junction Box Min. 11/16" (1.75 cm) - Wooden cabinet thickness If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and the wire gauge are in accordance with local codes. Check with a qualified electrical installer if you are not sure the oven is properly grounded. This oven must be connected to a grounded-metal permanent wiring system. Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all local codes and ordinances. A copy of the above code standards can be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 Install_NQ5300R_NQ70R5511DG_AA_DG68-01149A-04_EN.indd 6 11/11/2019 6:07:30 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

6 English
Preparation
Preparation
Cabinet dimensions - Combi. ovens
Combi Ovens Installed in Cabinet
01
Junction Box
02
Allow a minimum of 22” for clearance to adjacent corners, drawers, walls,
etc. when door is open
A
E
B
G
F
H
I
22”
D
C
J
02
01
Cabinet
DIMENSION
A
30” (76.2 cm)
B
Min. 1
3
/
16
” (3.0 cm)
C
12” (30.5 cm)
D
Min. 28
1
/
2
”/ Max. 28
5
/
8
” (Min. 72.4 cm / Max. 72.7 cm)
E
Min. 1”/ Max. 1
1
/
4
” (Min. 2.5 cm / Max. 3.2 cm)
F
42
1
/
4
” (107.2 cm)
Cabinet
DIMENSION
G
Min. 23
1
/
2
” (Min. 59.7 cm)
H
Min 30
1
/
2
" (Min 755 mm)
I
Max. 9
1
/
2
” (Max. 24.1 cm) – Junction Box
J
Min.
11
/
16
” (1.75 cm) - Wooden cabinet thickness
If codes permit and a separate ground wire is used, it is recommended that a
qualified electrical installer determine that the ground path and the wire gauge are
in accordance with local codes.
Check with a qualified electrical installer if you are not sure the oven is properly
grounded.
This oven must be connected to a grounded-metal permanent wiring system.
Be sure that the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA
Standards C22.
1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all
local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Install_NQ5300R_NQ70R5511DG_AA_DG68-01149A-04_EN.indd
6
11/11/2019
6:07:30 PM