Samsung TXJ2766 Service Manual - Page 3

Safety Precautions

Page 3 highlights

Precautions 1. Precautions Follow these safety, servicing and ESD precautions to prevent damage and protect against potential hazards such as electrical shock and X-rays. 1-1 Safety Precautions 1. Be sure that all of the built-in protective devices are replaced. Restore any missing protective shields. 2. When reinstalling the chassis and its assemblies, be sure to restore all protective devices, including: nonmetallic control knobs and compartment covers. 3. Make sure that there are no cabinet openings through which peopleÑparticularly childrenÑmight insert fingers and contact dangerous voltages. Such openings include the spacing between the picture tube and the cabinet mask, excessively wide cabinet ventilation slots, and improperly fitted back covers. If the measured resistance is less than 1.0 megohm or greater than 5.2 megohms, an abnormality exists that must be corrected before the unit is returned to the customer. 4. Leakage Current Hot Check (Figure 1-1): Warning: Do not use an isolation transformer during this test. Use a leakagecurrent tester or a metering system that complies with American National Standards Institute (ANIS C101.1, Leakage Current for Appliances), and Underwriters Laboratories (UL Publication UL1410, 59.7). 5. With the unit completely reassembled, plug the AC line cord directly into the power outlet. With the unitÕs AC switch first in the ON position and then OFF, measure the current between a known earth ground (metal water pipe, conduit, etc.) and all exposed metal parts, including: antennas, handle brackets, metal cabinets, screwheads and control shafts. The current measured should not exceed 0.5 milliamp. Reverse the powerplug prongs in the AC outlet and repeat the test. DEVICE UNDER TEST TEST ALL EXPOSED METAL SURFACES 2-WIRE CORD ALSO TEST WITH PLUG REVERSED (USING AC ADAPTER PLUG AS REQUIRED) LEAKAGE CURRENT TESTER (READING SHOULD NOT BE ABOVE 0.5mA) EARTH GROUND Fig. 1-1 AC Leakage Test 6. Antenna Cold Check: With the unitÕs AC plug disconnected from the AC source, connect an electrical jumper across the two AC prongs. Connect one lead of the ohmmeter to an AC prong. Connect the other lead to the coaxial connector. 7. X-ray Limits: The picture tube is especially designed to prohibit X-ray emissions. To ensure continued X-ray protection, replace the picture tube only with one that is the same type as the original. Carefully reinstall the picture tube shields and mounting hardware; these also provide X-ray protection. 8. High Voltage Limits: High voltage must be measured each time servicing is done on the B+, horizontal deflection or high voltage circuits. Correct operation of the X-ray protection circuits must be reconfirmed whenever they are serviced. (X-ray protection circuits also may be called Òhorizontal disableÓ or Òhold-downÓ.) Heed the high voltage limits. These include the XÐray Protection Specifications Label, and the Product Safety and X-ray Warning Note on the service data schematic. Samsung Electronics 1-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

1. Precautions
1-1 Safety Precautions
1.
Be sure that all of the built-in protective
devices are replaced.
Restore any missing
protective shields.
2.
When reinstalling the chassis and its
assemblies, be sure to restore all protective
devices, including: nonmetallic control knobs
and compartment covers.
3.
Make sure that there are no cabinet openings
through which people°particularly
children°might insert fingers and contact
dangerous voltages.
Such openings include
the spacing between the picture tube and the
cabinet mask, excessively wide cabinet
ventilation slots, and improperly fitted back
covers.
If the measured resistance is less than 1.0
megohm or greater than 5.2 megohms, an
abnormality exists that must be corrected
before the unit is returned to the customer.
4.
Leakage Current Hot Check (Figure 1-1):
Warning: Do not use an isolation
transformer during this test.
Use a leakage-
current tester or a metering system that
complies with American National Standards
Institute (ANIS
C101.1, Leakage Current for
Appliances), and Underwriters Laboratories
(UL Publication UL1410, 59.7).
5.
With the unit completely reassembled, plug
the AC line cord directly into the power
outlet.
With the unit±s AC switch first in the
ON position and then OFF, measure the
current between a known earth ground (metal
water pipe, conduit, etc.) and all exposed
metal parts, including: antennas, handle
brackets, metal cabinets, screwheads and
control shafts.
The current measured should
not exceed 0.5 milliamp.
Reverse the power-
plug prongs in the AC outlet and repeat the
test.
Fig. 1-1 AC Leakage Test
6.
Antenna Cold Check:
With the unit±s AC plug disconnected from the
AC source, connect an electrical jumper across
the two AC prongs.
Connect one lead of the
ohmmeter to an AC prong.
Connect the other
lead to the coaxial connector.
7.
X-ray Limits:
The picture tube is especially designed to
prohibit X-ray emissions. To ensure continued
X-ray protection, replace the picture tube only
with one that is the same type as the original.
Carefully reinstall the picture tube shields and
mounting hardware; these also provide X-ray
protection.
8.
High Voltage Limits:
High voltage must be measured each time
servicing is done on the B+, horizontal
deflection or high voltage circuits.
Correct
operation of the X-ray protection circuits must
be
reconfirmed whenever they are serviced.
(X-ray protection circuits also may be called
²horizontal disable³ or ²hold-down³.)
Heed the high voltage limits. These include
the X—ray Protection Specifications Label, and
the Product Safety and X-ray Warning Note on
the service data
schematic.
Precautions
Samsung Electronics
1-1
LEAKAGE
CURRENT
TESTER
DEVICE
UNDER
TEST
TEST ALL
EXPOSED METAL
SURFACES
2-WIRE CORD
ALSO TEST WITH
PLUG REVERSED
(USING AC ADAPTER
PLUG AS REQUIRED)
EARTH
GROUND
(READING SHOULD
NOT BE ABOVE
0.5mA)
Follow these safety, servicing and ESD precautions to prevent damage and protect against potential
hazards such as electrical shock and X-rays.