PLC-ET30L Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command "CF_FSYNC_%1" [CR] "0000-0031 Directly specify setting value of Fine Sync %1 "UP Increment setting value of Fine Sync by 1 "DN Decrement setting value of Fine Sync by 1 Details Set value of Fine Sync in PC signal (Available only in the normal Power ON status) The value set by this command will not be stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.) Acceptable "000" [CR] Response Unacceptable "101" [CR] --- When input is Video signal / No signal 8.5.2 CF_TDOTS Command Command "CF_TDOTS_%1" [CR] %1 Details Response "mmmm - nnnn Directly specify setting value of Total Dots "mmmm" indicates minimum value, which is current (Display area H + Position H) value "nnnn" indicates maximum value, whichi is less than 140 MHz in Dot Clocks "UP Increment setting value of Total Dots by 1 "DN Decrement setting value of Total Dots by 1 Set value of Total Dots in PC signal (Available only in the normal Power ON status) The value set by this command will not be stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.) Acceptable "000" [CR] Unacceptable "101" [CR] --- When input is Video signal / No signal 8.5.3 CF_CLPPHASE Command Command "CF_CLPPHASE_%1"[CR] "mmmm~nnnn" --- Directly select Clamp phase setting value "mmmm" shows minimum value, the fixed-value "0001". %1 "nnnn" shows maximum value, it depends on input signal. "UP Current Clamp setting value + 1 "DN Current Clamp setting value - 1 Details Set Clamp value of PC signal (Available only in the normal Power ON status) The value set by this command will not be saved to the projector. Therefore, when ALL is OFF, the value returns to the original setting (The value is held in Suspend mode) Acceptable "000"[CR] Response Unacceptable "101"[CR] ---- When input is Video signal / No signal 8.5.4 CF_H-POS Command Command "CF_H-POS_%1" [CR] "0000-nnnn" -------- Directly specify setting value of Horizontal Position %1 "nnnn" indicates maximum value, which is current value of (Total dots - Display area H) "UP Increment setting value of Horizontal Position by 1 "DN Decrement setting value of Horizontal Position by 1 Details Set value of Horizontal Position in PC signal (Available only in the normal Power ON status) The value set by this command will not be stored in the projector's memory. 20/62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

PLC-ET30L Expand Serial Command Functional Specifications
20/62
8.5 PC Adjust Control Command
8.5.1 CF_FSYNC Command
Command
“CF_FSYNC_%1” [CR]
%1
“0000-0031” ----------------- Directly specify setting value of Fine Sync
“UP” --------------------------- Increment setting value of Fine Sync by 1
“DN” --------------------------- Decrement setting value of Fine Sync by 1
Details
Set value of Fine Sync in PC signal (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Response
Acceptable
“000” [CR]
Unacceptable
“101” [CR] --- When input is Video signal / No signal
8.5.2 CF_TDOTS Command
Command
“CF_TDOTS_%1” [CR]
%1
“mmmm - nnnn” --------------- Directly specify setting value of Total Dots
“mmmm” indicates minimum value, which is current (Display area H + Position H)
value
“nnnn” indicates maximum value, whichi is
less than 140 MHz in Dot Clocks
“UP” ------------------------- Increment setting value of Total Dots by 1
“DN” ------------------------- Decrement setting value of Total Dots by 1
Details
Set value of Total Dots in PC signal (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Response
Acceptable
“000” [CR]
Unacceptable
“101” [CR] --- When input is Video signal / No signal
8.5.3 CF_CLPPHASE Command
Command
“CF_CLPPHASE_%1”[CR]
%1
“mmmm~nnnn” --- Directly select Clamp phase setting value
“mmmm” shows minimum value, the fixed-value “0001”.
“nnnn” shows maximum value, it depends on input signal.
“UP” -------------- Current Clamp setting value + 1
“DN” -------------- Current Clamp setting value – 1
Details
Set Clamp value of PC signal (Available only in the normal Power ON status)
The value set by this command will not be saved to the projector. Therefore, when
ALL is OFF, the value returns to the original setting (The value is held in Suspend
mode)
Response
Acceptable
“000”[CR]
Unacceptable
“101”[CR] ---- When input is Video signal / No signal
8.5.4 CF_H-POS Command
Command
“CF_H-POS_%1” [CR]
%1
“0000-nnnn” -------- Directly specify setting value of Horizontal Position
“nnnn” indicates maximum value, which is current value of (Total dots - Display area H)
“UP” ------------------- Increment setting value of Horizontal Position by 1
“DN” ------------------ Decrement setting value of Horizontal Position by 1
Details
Set value of Horizontal Position in PC signal (Available only in the normal Power
ON status)
The value set by this command will not be stored in the projector’s memory.