PLC-ET30L Expand Serial Command Functional Specifications 8.6.7 CF_SYSTEM Command Command "CF_SYSTEM_%1" [CR] Input is PC Analog "VGA1 Select VGA1 "VGA2 Select VGA2 : : "XGA1 Select XGA1 : : "WXGA3 Select WXGA3 "1080I Select 1080i "1035I Select 1035i "720p Select 720p "575p Select 575p "480p Select 480p "575I Select 575i "480I Select 480i "MODE1 - 10 Select MODE1 - MODE10 "EXT11 - 60 Select Ex Mode11-60 * EXT1-10 is not set. "D-XGA1 Select D-XGA1 : %1 Input is : "D-WXGA3 Select D-WXGA3 PC Digital/AV "D-1080I Select D-1080i HDCP "D-1035I Select D-1035i "D-720p Select D-720p "D-575p Select D-575p "D-480p Select D-480p Input is Y,Pb/Cb,Pr/Cr "AUTO Select System "Auto" "1080I Select 1080i "1035I Select 1035i "720P Select 720p "575P Select 575p "480P Select 480p "575I Select 575i "480I Select 480i Input is Video / S-Video "AUTO Select System "Auto" "NTSC Select NTSC "NTSC443 Select NTSC4.43 "PAL Select PAL "SECAM Select SECAM "PAL-M Select PAL-M "PAL-N Select PAL-N Details Select System of currently selected Input (Available only in the normal Power ON status) When selected input does not include specified %1, error code "101" [CR] is returned and it is not executed. When Input No is 4, error code "101" [CR] is returned and it is not executed. Acceptable Response Unacceptable "000" [CR] "Error Code" [CR] 26/62