Sanyo PLC-WL2503 RS232C Expand - Page 39

CF_HDMI SOUND Command, 10.14 CF_TERMINAL Command, 10.15, CF_STANDBYMODE Command, 10.16 CF_P-

Page 39 highlights

PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications 8.10.13 CF_HDMI SOUND Command Command "CF_HDMI SOUND_%1"[CR] %1 "HDMI Select PCM sound (Digital sound) "EXTERNAL Select External sound input Details Select sound mode of HDMI setup. The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.14 CF_TERMINAL Command Command "CF_TERMINAL_%1"[CR] %1 "COMPUTER Set Input mode "MONITOR Set Monitor Out mode Details Set Terminal setup. This command is available in normal Power ON status. Terminal means Computer 2 in this model. Acceptable "000"[CR] Response "Error Code"[CR] Unacceptable When Input is Computer 2, the projector returns "101" and the command is not executed. 8.10.15 CF_STANDBYMODE Command Command "CF_STANDBYMODE_%1"[CR] %1 "ECO Less standby electricity "NORMAL Normal standby electricity Details Switch Standby Mode setting. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.16 CF_P-MANE Command Command "CF_P MANE_%1"[CR] "OFF Set Power Management to OFF "READY Set Power Management to Ready "SHUTDOWN Set Power Management to Shut Down mode %1 "UP Switch Power management setting (Off → Ready → Shutdown → Off) "DN Switch Power management setting (Off → Shutdown → Ready → Off) Details Set/Cancel Power Management The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 38/72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PLC-WL2500 / WL2501/ WL2503
Expand Serial Command Functional Specifications
38/72
8.10.13 CF_HDMI SOUND Command
Command
“CF_HDMI SOUND_%1”[CR]
%1
“HDMI” ----------------------- Select PCM sound (Digital sound)
“EXTERNAL” ------------- Select External sound input
Details
Select sound mode of HDMI setup.
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.14 CF_TERMINAL Command
Command
“CF_TERMINAL_%1”[CR]
%1
“COMPUTER” ----------------Set Input mode
“MONITOR” ------------------- Set Monitor Out mode
Details
Set Terminal setup. This command is available in normal Power ON status.
Terminal means Computer 2 in this model.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
When Input is Computer 2, the projector returns “101” and the
command is not executed.
8.10.15
CF_STANDBYMODE Command
Command
“CF_STANDBYMODE_%1”[CR]
%1
“ECO” ---------------------- Less standby electricity
“NORMAL” --------------- Normal standby electricity
Details
Switch Standby Mode setting.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.16 CF_P-MANE Command
Command
“CF_P
MANE_%1”[CR]
%1
“OFF” --------------------------------- Set Power Management to OFF
“READY” ----------------------------- Set Power Management to Ready
“SHUTDOWN” --------------------- Set Power Management to Shut Down mode
“UP” ------------------------------ Switch Power management setting
(Off
Ready
Shutdown
Off)
“DN” ------------------------------ Switch Power management setting
(Off
Shutdown
Ready
Off)
Details
Set/Cancel Power Management
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]