Seagate ST1.3 ST1.3 Series Product Manual - Page 17

Environmental specifications

Page 17 highlights

2.8 Environmental specifications 2.8.1 Ambient temperature Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 70°C (158°F) within the operating ambient conditions. Case temperature of the drive operating at 60°C ambient may hit a maximum of 70°C at certain parts of the casing. Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet. Operating 0° to 60°C (32° to 140°F) (70°C max case temperature) Nonoperating -40° to 70°C (-40° to 158°F) 2.8.2 Temperature gradient Operating 20°C per hour (36°F per hour max), without condensation Nonoperating 30°C per hour (54°F per hour max), without condensation 2.8.3 Humidity 2.8.3.1 Relative humidity Operating 5% to 90% noncondensing (30% per hour max) Nonoperating 5% to 95% noncondensing (30% per hour max) 2.8.3.2 Wet bulb temperature Operating 33°C (91.4°F max) [1] Nonoperating 40°C (104°F max) [2] [1] Operating: Wet bulb temperature is calculated by the operating Temperature and the Relative Humidity levels. [2] Nonoperating: Wet bulb temperature is calculated by the nonoperating Temperature and the Relative Humidity levels. 2.8.4 Altitude Operating -60.98 m to 3,048 m (-200 ft to 10,000+ ft) Nonoperating -60.98 to 12,192 m (-200 ft to 40,000+ ft) ST1.3 Series Product Manual, Rev. D 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

ST1.3 Series Product Manual, Rev. D
11
2.8
Environmental specifications
2.8.1
Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Actual drive case temperature should not exceed
70°C (158°F) within the operating ambient conditions. Case
temperature of the drive operating at 60°C ambient may hit a maximum of 70°C at certain parts of the casing.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.
2.8.2
Temperature gradient
2.8.3
Humidity
2.8.3.1
Relative humidity
2.8.3.2
Wet bulb temperature
[1]
Operating: Wet bulb temperature is calculated by the operating Temperature and the Relative Humidity levels.
[2]
Nonoperating: Wet bulb temperature is calculated by the nonoperating Temperature and the Relative Humidity levels.
2.8.4
Altitude
Operating
0° to 60°C (32° to 140°F)
(70°C max case temperature)
Nonoperating
–40° to 70°C (–40° to 158°F)
Operating
20°C per hour (36°F per hour max), without condensation
Nonoperating
30°C per hour (54°F per hour max), without condensation
Operating
5% to 90% noncondensing (30% per hour max)
Nonoperating
5% to 95% noncondensing (30% per hour max)
Operating
33°C (91.4°F max) [1]
Nonoperating
40°C (104°F max) [2]
Operating
–60.98 m to 3,048 m (–200 ft to 10,000+ ft)
Nonoperating
–60.98 to 12,192 m (–200 ft to 40,000+ ft)