Seagate ST3146854FC Cheetah 15K.4 FC Product Manual - Page 63

Fibre Channel Process Login Accept, Fibre Channel fabric login

Page 63 highlights

9.1.7 Fibre Channel Process Login Accept Table 10 lists Cheetah 15K.4 FC process login accept payload data. Table 10: Process Login Accept (ACC) payload Bytes 0-15 16-31 02 10 00 14 08 00 21 00 00 00 00 00 00 00 00 00 00 00 00 12 9.1.8 Fibre Channel fabric login Table 11 lists the fabric login payload from the drive. Table 11: Fabric Login (FLOGI) payload Bytes 0-15 04 00 00 00 09 09 00 00 08 00 08 40 00 00 00 00 Common 16-31 00 00 02 F4 2P 00 CC CC CC UI UI UI 02 00 CC CC 32-35 CC UI UI UI 36-47 00 00 00 00 00 00 00 00 00 00 00 00 Class 1 48-51 00 00 00 00 52-63 00 00 00 00 00 00 00 00 00 00 00 00 Class 2 64-67 00 00 00 00 68-79 80 00 00 00 00 00 08 40 00 00 00 00 Class 3 80-83 00 00 00 00 84-95 00 00 00 00 00 00 00 00 00 00 00 00 Reserved 96-99 00 00 00 00 100-111 00 00 00 00 00 00 00 00 00 00 00 00 Vendor - 112-115 00 00 00 00 Version CC Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change). UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and Node Name fields. P Port identifier field. 1 FLOGI originated on Port A. 2 FLOGI originated on Port B. Cheetah 15K.4 FC Product Manual, Rev. C 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

Cheetah 15K.4 FC Product Manual, Rev. C
51
9.1.7
Fibre Channel Process Login Accept
Table 10 lists Cheetah 15K.4 FC process login accept payload data.
9.1.8
Fibre Channel fabric login
Table 11 lists the fabric login payload from the drive.
Table 10:
Process Login Accept (ACC) payload
Bytes
0-15
02
10
00
14
08
00
21
00
00
00
00
00
00
00
00
00
16-31
00
00
00
12
Table 11:
Fabric Login (FLOGI) payload
Bytes
0-15
04
00
00
00
09
09
00
00
08
00
08
40
00
00
00
00
Common
16-31
00
00
02
F4
2P
00
CC
CC
CC
UI
UI
UI
02
00
CC
CC
32-35
CC
UI
UI
UI
36-47
00
00
00
00
00
00
00
00
00
00
00
00
Class 1
48-51
00
00
00
00
52-63
00
00
00
00
00
00
00
00
00
00
00
00
Class 2
64-67
00
00
00
00
68-79
80
00
00
00
00
00
08
40
00
00
00
00
Class 3
80-83
00
00
00
00
84-95
00
00
00
00
00
00
00
00
00
00
00
00
Reserved
96-99
00
00
00
00
100-111
00
00
00
00
00
00
00
00
00
00
00
00
Vendor -
112-115
00
00
00
00
Version
CC
Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change).
UI
Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and
Node Name fields.
P
Port identifier field.
1
FLOGI originated on Port A.
2
FLOGI originated on Port B.