Seagate ST336607LW ST3146807LC Model Product Manual PDF - Page 42

Cheetah 10K.6 SCSI Product Manual, Rev. D, 4.4.2, Vibration, Air cleanliness, Acoustics,

Page 42 highlights

32 Cheetah 10K.6 SCSI Product Manual, Rev. D 6.4.4.2 Vibration a. Operating - normal The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding 5-500 Hz @ 0.5 G (zero to peak) Vibration may be applied in the X, Y, or Z axis. Operating normal translational random flat profile 10 - 400 Hz 0.4 GRMS b. Operating - abnormal Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding: 15 minutes of duration at major resonant frequency 5-500 Hz @ 0.75 G (X, Y, or Z axis, zero to peak) Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available. Operating abnormal translational random flat profile 10 - 400 Hz 1.2 GRMS c. Non-operating The limits of non-operating vibration shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives. The drive shall not incur physical damage or degraded performance as a result of continuous vibration not exceeding 5-22 Hz @ 0.040 inches (1.02 mm) displacement (zero to peak) 22-500 Hz @ 2.00 G (zero to peak) Vibration may be applied in the X, Y, or Z axis. Non-operating translational random flat profile 10 - 400 Hz 1.2 GRMS 6.4.5 Air cleanliness The drive is designed to operate in a typical office environment with minimal environmental control. 6.4.6 Acoustics Sound power during idle mode shall be 3.7 bels typical when measured to ISO 7779 specification. There will not be any discrete tones more than 10 dB above the masking noise on typical drives when measured according to Seagate specification 30553-001. There will not be any tones more than 24 dB above the masking noise on any drive. 6.4.7 Electromagnetic susceptibility See Section 2.1.2.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

32
Cheetah 10K.6 SCSI Product Manual, Rev. D
6.4.4.2
Vibration
a.
Operating - normal
The drive as installed for normal operation, shall comply with the complete specified performance while
subjected to continuous vibration not exceeding
5-500 Hz @ 0.5 G (zero to peak)
Vibration may be applied in the X, Y, or Z axis.
Operating normal translational random flat profile
10 - 400 Hz
0.4 GRMS
b.
Operating - abnormal
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic
vibration not exceeding:
15 minutes of duration at major resonant frequency
5-500 Hz @ 0.75 G (X, Y, or Z axis, zero to peak)
Vibration occurring at these levels may degrade operational performance during the abnormal vibration
period. Specified operational performance will continue when normal operating vibration levels are
resumed. This assumes system recovery routines are available.
Operating abnormal translational random flat profile
10 - 400 Hz
1.2 GRMS
c. Non-operating
The limits of non-operating vibration shall apply to all conditions of handling and transportation. This
includes both isolated drives and integrated drives.
The drive shall not incur physical damage or degraded performance as a result of continuous vibration not
exceeding
5-22 Hz @ 0.040 inches (1.02 mm) displacement (zero to peak)
22-500 Hz @ 2.00 G (zero to peak)
Vibration may be applied in the X, Y, or Z axis.
Non-operating translational random flat profile
10 - 400 Hz
1.2 GRMS
6.4.5
Air cleanliness
The drive is designed to operate in a typical office environment with minimal environmental control.
6.4.6
Acoustics
Sound power during idle mode shall be 3.7 bels typical when measured to ISO 7779 specification.
There will not be any discrete tones more than 10 dB above the masking noise on typical drives when mea-
sured according to Seagate specification 30553-001. There will not be any tones more than 24 dB above the
masking noise on any drive.
6.4.7
Electromagnetic susceptibility
See Section 2.1.2.