Seagate ST340014A Barracuda 7200.7 PATA Product Manual - Page 37

The Identify Device command command code EC - firmware 1 10

Page 37 highlights

4.1.2 Identify Device command The Identify Device command (command code ECH) transfers information about the drive to the host following power up. The data is organized as a single 512-byte block of data, whose contents are shown in the table on page 27. All reserved bits or words should be set to zero. Parameters listed with an "x" are drive-specific or vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings. The following commands contain drive-specific features that may not be included in the Draft ATA-6 Standard. Word 0 1 2 3 4 5 6 7-9 10-19 20 21 22 23-26 27-46 47 48 49 50 51 52 53 54 Description Configuration information: • Bit 15: 0 = ATA; 1 = ATAPI • Bit 7: removable media • Bit 6: removable controller • Bit 0: reserved Number of logical cylinders ATA-reserved Number of logical heads Retired Retired Number of logical sectors per logical track: 63 Retired Serial number: (20 ASCII characters, 0000H = none) Retired Retired Obsolete Firmware revision (8 ASCII character string, padded with blanks to end of string) Drive model number (40 ASCII characters, padded with blanks to end of string) (Bits 7-0) Maximum sectors per interrupt on Read multiple and Write multiple (16) Reserved Standard Standby timer, IORDY supported and may be disabled ATA-reserved PIO data-transfer cycle timing mode Retired Words 54-58, 64-70 and 88 are valid Number of current logical cylinders Value 0C5AH 16,383 0000H 16 0000H 0000H 003FH 0000H ASCII 0000H 0400H 0000H x.xx ST3200822A ST3200021A ST3160023A ST3160021A ST3120026A ST3120022A ST380013A ST380011A ST340014A 8010H 0000H 2F00H 0000H 0200H 0200H 0007H xxxxH Barracuda 7200.7 Product Manual, Rev. N 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Barracuda 7200.7 Product Manual, Rev. N
29
4.1.2
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following
power up. The data is organized as a single 512-byte block of data, whose contents are shown in the table on
page 27. All reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or
vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings.
The following commands contain drive-specific features that may not be included in the
Draft ATA-6 Standard.
Word
Description
Value
0
Configuration information:
• Bit 15: 0 = ATA; 1 = ATAPI
• Bit 7: removable media
• Bit 6: removable controller
• Bit 0: reserved
0C5A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4
Retired
0000
H
5
Retired
0000
H
6
Number of logical sectors per logical track: 63
003F
H
7–9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
= none)
ASCII
20
Retired
0000
H
21
Retired
0400
H
22
Obsolete
0000
H
23–26
Firmware revision (8 ASCII character string, padded with blanks to end
of string)
x.xx
27–46
Drive model number
(40 ASCII characters, padded with blanks to end of string)
ST3200822A
ST3200021A
ST3160023A
ST3160021A
ST3120026A
ST3120022A
ST380013A
ST380011A
ST340014A
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple and Write
multiple (16)
8010
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY supported and may be disabled
2F00
H
50
ATA-reserved
0000
H
51
PIO data-transfer cycle timing mode
0200
H
52
Retired
0200
H
53
Words 54–58, 64–70 and 88 are valid
0007
H
54
Number of current logical cylinders
xxxx
H