Seagate ST340014A Barracuda 7200.7 PATA Product Manual - Page 39

Advanced Power Management APM and Automatic Acoustic Management AAM features are not supported

Page 39 highlights

Word 100-103 Description Total number of user-addressable LBA sectors available (see Section 2.2 for related information) These words are required for drives that support the 48-bit addressing feature. Maximum value: 0000FFFFFFFFFFFFh. 104-127 128 129-159 160-254 255 ATA-reserved Security status Seagate-reserved ATA-reserved Integrity word Value ST3200822A = 390,721,968 ST3200021A = 390,721,968 ST3160023A = 312,581,808 ST3160021A = 312,581,808 ST3120026A = 234,441,648 ST3120022A = 234,441,648 ST380013A = 156,301,488 ST380011A = 156,301,488 ST340014A = 78,165,360 0000H 0001H xxxxH 0000H xxA5H Note. Advanced Power Management (APM) and Automatic Acoustic Management (AAM) features are not supported Note. See the bit descriptions below for words 63, 88, and 93 of the Identify Drive data: Description (if bit is set to 1) Bit Word 63 0 Multiword DMA mode 0 is supported. 1 Multiword DMA mode 1 is supported. 2 Multiword DMA mode 2 is supported. 8 Multiword DMA mode 0 is currently active. 9 Multiword DMA mode 1 is currently active. 10 Multiword DMA mode 2 is currently active. Bit Word 88 0 Ultra DMA mode 0 is supported. 1 Ultra DMA mode 1 is supported. 2 Ultra DMA mode 2 is supported. 3 Ultra DMA mode 3 is supported. 4 Ultra DMA mode 4 is supported. 8 Ultra DMA mode 0 is currently active. 9 Ultra DMA mode 1 is currently active. 10 Ultra DMA mode 2 is currently active. 11 Ultra DMA mode 3 is currently active. 12 Ultra DMA mode 4 is currently active. 13 Ultra DMA mode 5 is currently active. Bit Word 93 13 1 = 80-conductor cable detected, CBLID above VIH 0 = 40-conductor cable detected, CBLID below VIL Barracuda 7200.7 Product Manual, Rev. N 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Barracuda 7200.7 Product Manual, Rev. N
31
Note.
Advanced Power Management (APM) and Automatic Acoustic Management (AAM) features are not supported
Note.
See the bit descriptions below for words 63, 88, and 93 of the Identify Drive data:
100–103
Total number of user-addressable LBA sectors available
(see Section 2.2 for related information)
These words are required for drives that support the 48-bit addressing
feature. Maximum value: 0000FFFFFFFFFFFFh.
ST3200822A = 390,721,968
ST3200021A = 390,721,968
ST3160023A = 312,581,808
ST3160021A = 312,581,808
ST3120026A = 234,441,648
ST3120022A = 234,441,648
ST380013A = 156,301,488
ST380011A = 156,301,488
ST340014A = 78,165,360
104–127
ATA-reserved
0000
H
128
Security status
0001
H
129–159
Seagate-reserved
xxxx
H
160–254
ATA-reserved
0000
H
255
Integrity word
xxA5
H
Description (if bit is set to 1)
Bit
Word 63
0
Multiword DMA mode 0 is supported.
1
Multiword DMA mode 1 is supported.
2
Multiword DMA mode 2 is supported.
8
Multiword DMA mode 0 is currently active.
9
Multiword DMA mode 1 is currently active.
10
Multiword DMA mode 2 is currently active.
Bit
Word 88
0
Ultra DMA mode 0 is supported.
1
Ultra DMA mode 1 is supported.
2
Ultra DMA mode 2 is supported.
3
Ultra DMA mode 3 is supported.
4
Ultra DMA mode 4 is supported.
8
Ultra DMA mode 0 is currently active.
9
Ultra DMA mode 1 is currently active.
10
Ultra DMA mode 2 is currently active.
11
Ultra DMA mode 3 is currently active.
12
Ultra DMA mode 4 is currently active.
13
Ultra DMA mode 5 is currently active.
Bit
Word 93
13
1 = 80-conductor cable detected, CBLID above V
IH
0 = 40-conductor cable detected, CBLID below V
IL
Word
Description
Value