Sharp KB3401LK KB-3401LS , KB-3401LK , KB-3401LW Installation Instructions - Page 5

Installation Manual - range

Page 5 highlights

Installation Manual frame where the ground screw was originally installed. See Figure 8. 5 Make sure all screws are tightened securely and replace the rear access cover and secure with screw. See Figure 6. 3-Wire Connection Instructions For existing installations ONLY, refer to Figure 9. 1 Follow the power supply cord kit manufacturer's Installation Instructions and install the strain relief clamp. See Figure 7. 2 Connect the end connectors for line 1, line 2 and neutral and tighten securely to the terminal block. See Figure 9. IMPORTANT DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block. Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed. 3 A ground strap is installed on this range which connects the center terminal of the neutral terminal block to the range chassis. The ground strap is connected to the range by the center, lowest screw. See Figure 9. The ground strap must not be removed unless National, State or Local Codes do not permit use of a ground strap. NOTE: If the ground strap is removed for any reason, a separate ground wire must be connected to the separate ground screw attached to the range chassis and to an adequate ground source. 4 Make sure all connections are tightened securely and replace the rear access cover and secure with screw. See Figure 6. 4-Wire Connection 3 & 4-WIRE PERMANENT WIRE CONNECTIONS 3-wire permanent connection - follow steps 1, 2 and 5 below. 4-wire permanent connection - follow all steps below. Before wiring the range, review the suggested power source location drawings in Figure 2. If connecting to a 4-wire electrical system: 1 Follow the manufacturer's Installation Instructions for installing the strain relief clamp. 2 Strip insulation away from the ends of the permanent wiring for line 1, line 2 and neutral; also strip ground wire on 4-wire connections. Tighten all 3 or 4-wire leads to the terminal block. Follow wire locations shown in Figure 10. IMPORTANT DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block. Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed. NOTE: For 3-wire permanent connection skip steps 3 and 4 and continue with step 5. 3 Disconnect the ground strap. Remove the factory installed ground screw and plate to release the factory installed copper ground strap from frame of the range. Cut and discard the copper strap from the terminal block. KEEP the ground screw, ground plate and go to step 4. 4 Connect the green ground wire lead to the frame of the range using the ground screw and plate as shown in Figure 11. Be sure to install using the same hole in the frame where the ground screw was originally installed. 5 Make sure all connections are tightened securely and replace the rear access cover and secure with screw. See Figure 6. Connect line 1 here. Cut ground strap. Discard ground strap and ground plate. Connect green lack insulated copper ground wire with en ground screw here. Figure 8 red white gre b Note: Install strain relief clamp. Center or white wire must always be attached to the center terminal on block. NOTE: Non-terminated field wire compression connections must be set at approximately 90 in./lb. For 3 & 4-Wire Permanent Connections Terminal block Connect line 2 here. Connect neutral (white or center) here. A user supplied strain relief clamp must be installed at this location. It requires 1 3/8" (3.5 cm) diameter cord kit hole. terminal block line 1 terminal block line 1 neutral Figure 10 line 2 neutral ground strap line 2 ground plate ground strapground ground platescrew 3-Wire Connection 4-Wire Pgsecrorreuwnmd anent Connection only Connect line 1 here. Ground strap Note: Install strain relief clamp. Center must always be attached to the center terminal on block. Figure 9 Terminal block Connect line 2 here. Connect neutral here. A user supplied strain relief clamp must be installed at this location. It requires 1 3/8" (3.5 cm) diameter cord kit hole. ground plate ground plate ground screw ground screw pfporerorp4mgw-earwirorneiugreenrlneodtaudnd ground wire lead Figure 11  proper ground for 4-wire permanent

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

5
INSTALLATION MANUAL
frame where the ground screw was originally installed. See
Figure 8.
5
Make sure all screws are tightened securely and replace the
rear access cover and secure with screw. See Figure 6.
³-WIRE CONNECTION INSTRUCTIONS
For existing installations ONLY, refer to Figure 9.
±
Follow the power supply cord kit manufacturer’s Installation
Instructions and install the strain relief clamp. See
Figure 7.
²
Connect the end connectors for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 9.
IMPORTANT
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block.
Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
³
A ground strap is installed on this range which connects the
center terminal of the neutral terminal block to the range
chassis. The ground strap is connected to the range by the
center, lowest screw. See Figure 9.
The ground strap must not
be removed unless National, State or Local Codes do not permit
use of a ground strap.
NOTE:
If the ground strap is removed for any reason, a
separate ground wire must be connected to the separate ground
screw attached to the range chassis and to an adequate ground
source.
´
Make sure all connections are tightened securely and replace
the rear access cover and secure with screw. See Figure 6.
terminal
block
ground
screw
ground plate
ground strap
line 2
neutral
line 1
Figure ±0
ground
screw
ground
wire lead
ground
plate
proper ground
for 4-wire
permanent
Figure ±±
´-WIRE PERMANENT CONNECTION ONLY
FOR ³ & ´-WIRE PERMANENT CONNECTIONS
³ & ´-WIRE PERMANENT WIRE CONNECTIONS
3–wire permanent connection – follow steps 1, 2 and 5 below.
4–wire permanent connection – follow all steps below.
Before wiring the range, review the suggested power source location
drawings in Figure 2. If connecting to a 4-wire electrical system:
±
Follow the manufacturer’s Installation Instructions for installing
the strain relief clamp.
²
Strip insulation away from the ends of the permanent wiring
for line 1, line 2 and neutral; also strip ground wire on 4-wire
connections. Tighten all 3 or 4-wire leads to the terminal block.
Follow wire locations shown in Figure 10.
IMPORTANT
DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal
block. Electrical failure or loss of electrical connection may
occur if these 3 nuts are loosened or removed.
NOTE:
For 3-wire permanent connection skip steps 3 and 4
and continue with step 5.
³
Disconnect the ground strap. Remove the factory installed
ground screw and plate to release the factory installed copper
ground strap from frame of the range. Cut and discard the
copper strap from the terminal block. KEEP the ground screw,
ground plate and go to step 4.
´
Connect the green ground wire lead to the frame of the range
using the ground screw and plate as shown in Figure 11. Be sure
to install using the same hole in the frame where the ground
screw was originally installed.
5
Make sure all connections are tightened securely and replace
the rear access cover and secure with screw. See Figure 6.
NOTE:
Non-terminated field wire compression connections
must be set at approximately 90 in./lb.
Ground strap
Terminal block
Note:
Install strain
relief clamp. Center
must always be
attached to the
center terminal on
block.
Connect neutral
here.
Connect line
1 here.
Connect line 2 here.
A user supplied
strain relief clamp
must be installed
at this location. It
requires 1
3
/8"
(3.5 cm) diameter
cord kit hole.
Figure 9
³-WIRE CONNECTION
Terminal block
w
h
i
t
e
g
r
e
e
n
Connect green
insulated copper
ground wire with
ground screw
here.
Cut ground
strap. Discard
ground strap
and ground
plate.
Connect neutral (white
or center) here.
Connect
line 1 here.
Connect line 2 here.
b
l
a
c
k
Note:
Install strain
relief clamp. Center or
white wire must always
be attached to the
center terminal on
block.
A user supplied strain
relief clamp must be
installed at this
location. It requires 1
3
/8" (3.5 cm) diameter
cord kit hole.
r
e
d
Figure 8
´-WIRE CONNECTION