Sharp PN-V602 PN-V602 Operation Manual - Page 44

Others, Commands for setting of the GAMMA user data, Controlling the Monitor with a PC RS-232C

Page 44 highlights

Controlling the Monitor with a PC (RS-232C) Others Function SCREEN SIZE (PC) SCREEN SIZE (AV) VOLUME MUTE INFORMATION MODEL SERIAL NO BRIGHT TEMPERATURE SENSOR Command Direction WIDE WR WIDE WR VOLM WR MUTE WR INF1 R SRNO R VLMP WR DSTA R Parameter 1-5 1-5 0-31 0-1 0-31 Temperature acquisition ERRT R CAUSE OF LAST STANDBY MODE STCA W 0 R Reply Control/Response contents 1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2 1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot 0-31 0-1 0: OFF, 1: ON Value Value 0-31 0 Internal temperature normal 1 Internal temperature abnormal (Standby mode) 2 Internal temperature abnormal (Temperature is normal now, but it was abnormal during operation.) 3 Internal temperature abnormal (Brightness of the backlight decreases.) 4 Temperature sensor abnormal Value Temperature at temperature sensors 1 through 6 are returned in the following forms: [Sensor 1], [Sensor 2], [Sensor 3], [Sensor 4], [Sensor 5], [Sensor 6] Indicates a temperature sensor abnormality when "126" is returned. Initialization 0 No detectable error has occurred 1 Standby mode by POWER button 2 Main power off by the main power switch 3 Standby mode by RS-232C or LAN 4 Waiting mode by No Signal 6 Standby mode by abnormal temperature 8 Standby mode by SCHEDULE setting 20 Standby mode by OFF IF NO OPERATION setting *2 *1 (A) (B) ○ ○ ○ - ● ○ ● ○○ ○ ● Commands for setting of the GAMMA user data Function RED GAMMA DATA TRANSFER GREEN GAMMA DATA TRANSFER BLUE GAMMA DATA TRANSFER RED GAMMA DATA READ GREEN GAMMA DATA READ BLUE GAMMA DATA READ USER DATA INITIALIZE USER DATA SAVE Command Direction Parameter Reply UGRW W UGGW W UGBW W UGRR W UGGR W UGBR W UGRS W UGSV W aaxxxx ··· xxxxcc (xxxx: 32 pieces) aa: 01-16 xxxx: 0000-1023 cc: 00-FF 1-16 1-16 1-16 xxxx ··· xxxx (xxxx: 32 pieces) xxxx: 0000-1023 0 0 Control/Response contents aa: Block number xxxx: 32 pieces of user data cc: Checksum (ASCII data) of the block number and user data xxxx: User data of 32 pieces Initialize the user data. Save the user data in the monitor. *2 *1 (A) (B) ○○○ E 44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

E
44
Others
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
*2
(A) (B)
SCREEN SIZE (PC)
WIDE
WR
1-5
1-5
1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
SCREEN SIZE (AV)
WIDE
WR
1-5
1-5
1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
VOLUME
VOLM
WR
0-31
0-31
MUTE
MUTE
WR
0-1
0-1
0: OFF, 1: ON
-
INFORMATION
MODEL
INF1
R
Value
SERIAL NO
SRNO
R
Value
BRIGHT
VLMP
WR
0-31
0-31
TEMPERATURE SENSOR
DSTA
R
0
Internal temperature normal
1
Internal temperature abnormal (Standby mode)
2
Internal temperature abnormal (Temperature is normal now, but it was
abnormal during operation.)
3
Internal temperature abnormal (Brightness of the backlight decreases.)
4
Temperature sensor abnormal
TEMPERATURE ACQUISITION
ERRT
R
Value
Temperature at temperature sensors 1 through 6 are returned in the
following forms:
[Sensor 1], [Sensor 2], [Sensor 3], [Sensor 4], [Sensor 5], [Sensor 6]
Indicates a temperature sensor abnormality when “126” is returned.
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
R
0
No detectable error has occurred
1
Standby mode by POWER button
2
Main power off by the main power switch
3
Standby mode by RS-232C or LAN
4
Waiting mode by No Signal
6
Standby mode by abnormal temperature
8
Standby mode by SCHEDULE setting
20
Standby mode by OFF IF NO OPERATION setting
Commands for setting of the GAMMA user data
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
*2
(A) (B)
RED GAMMA DATA TRANSFER
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
GREEN GAMMA DATA TRANSFER
UGGW
W
BLUE GAMMA DATA TRANSFER
UGBW
W
RED GAMMA DATA READ
UGRR
W
1-16
xxxx ··· xxxx
(xxxx: 32 pieces)
xxxx: 0000-1023
xxxx: User data of 32 pieces
GREEN GAMMA DATA READ
UGGR
W
1-16
BLUE GAMMA DATA READ
UGBR
W
1-16
USER DATA INITIALIZE
UGRS
W
0
Initialize the user data.
USER DATA SAVE
UGSV
W
0
Save the user data in the monitor.