Sony FWD-32LX1 Protocol Manual - Page 20
Shutdown Log enquiry, Code Table4-c
View all Sony FWD-32LX1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
(g) Shutdown Log enquiry Syntax Enquiry Header 0x83 Category 0x30 Function 0x11 Data1 0xFF Data2 0xFF Check Sum 0xC0 Answer Header Answer Enquiry 0x70 Return Data1: 0x00 - 0xFF 0x00 Code Table(4-c) Return to Data Size 0x02 Return Data1 Code Table(4-c) Shutdown Information bit0 Reserved bit1 1: FAN operation is abnormal 0: Normal bit2 1: Backlight is abnormal 0: Normal bit3 1: Temperature sensor is abnormal 0: Normal bit4 1: Main power supply is abnormal 0: Normal bit5 1: Digital power supply is abnormal (3.3 V, 5 V) 0: Normal bit6 1: Analog supply is abnormal (5 V/9 V) 0: Normal bit7 1: Scaler is abnormal 0: Normal Check Sum 0xXX Completed Code Table(4-d) [a]Function [b]Range/Switch code Command Control Enquiry Standby Power On 0x00 Model Name 0x08 - 0x09 No Yes Enable Enable 0x01 Serial Number 0x001E8480 - 0x002DC6BF Yes (2,000,000 - 2,999,999) Yes Enable Enable 0x02 Operation Time 0x00000000 - 0xD693A3FF (0sec._3,599,999,999sec.) 0x03 Soft Version(Main) 0x0000 - 0xFFFF No Yes Enable Enable 0x07 Digital 3.3 V 0x00 - 0xFF 0x09 Digital 5 V 0x00 - 0xFF 0x0A Temp1 0x00 - 0xFF 0x0D Temp(P/S) 0x00 - 0xFF 0x0F Soft Version(Scaler) 0x0000 - 0xFFFF 0x10 Analog5 V/9 V 0x00 - 0xFF 0x11 Shutdown Log 0x00 - 0xFF 0x12 Digital 3.3 V(Failure) 0x00 - 0xFF 0x13 Digital 5 V(Failure) 0x00 - 0xFF 0x14 0x20 Analog5 V/9 V(Failure) 0x00 - 0xFF Busy to INPUT* 0x00 Non Busy 0x01 Busy * Busy to INPUT should be judged by Busy → Non Busy. Busy to INPUT may be incorrectly judged during start when it is judged by only Non Busy. 16 FWD-42LX1 FWD-32LX1