power inline consumption interface
View all TP-Link T1500G-10PS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 202 highlights
Syntax holiday { exclude | include } Parameter exclude --The final Time range will be the intersection of the Absolute Time and the Periodic Time, with Holiday excluded. include -- The Holiday has no effect on the Time-range, which means the final Time-range will be the intersection of the Absolute Time and Periodic Time. Command Mode Power Time-range Configuration Mode Privilege Requirement Only Admin, Operator and Power User level users have access to these commands. Example Create a holiday mode time-range for the PoE time-range named "tRange3" and configure PoE time-range of the switch excludes the PoE holiday: T1500G-10MPS(config)# power time-range tRange3 T1500G-10MPS(config-time-range)# holiday exclude 22.8 power inline consumption (interface) Description The power inline consumption command is used to configure the power limit the corresponding port can supply. Syntax power inline consumption { power-limit | auto | class1 | class2 | class3 | class4 } Parameter consumption -- The max power the port in the profile can supply. There are six options: "power-limit", "auto", "class1", "class2", "class3" and "class4". "power-limit" indicates you can manually enter a value. It ranges from 1 to 300. The value is in the unit of 0.1 watt. For instance, if you want to configure the max power as 5w, you should enter 50. "auto" indicates the value is assigned automatically by the PoE switch. "class1" represents 4w. "class2" represents 7w. "class3" represents 15.4w. "class4" represents 30w. 189