TRENDnet TFM-PCIV92A User Guide - Page 12

Appendix 3, S-Register Summary, Register, Function, Default, Range, Units - modem tfm

Page 12 highlights

TFM-PCIV92A User's Guide _____ AT Command prefix n = 14 44000 BPS n = 15 45333 BPS n = 16 46666 BPS n = 17 48000 BPS n = 18 49333 BPS n = 19 50666 BPS n = 20 52000 BPS n = 21 53333 BPS -V90? Reports current V.90 setting \A0 Set maximum MNP block size to 64 characters \A1 Set maximum MNP block size to 128 characters \A2 Set maximum MNP block size to 192 characters \A3 Set maximum MNP block size to 256 characters \Bn Transmit break in n*100ms (n = 0-9) \G0 Disables XON/XOFF flow control between local and remote modems \G1 Enables XON/XOFF flow control between local and remote modems \J0 Disables DTE speed adjust \J1 Enables DTE speed adjust \Kn Set break control (n=0-5, default is 5). \N0 Select normal mode \N1 Select normal mode \N2 Select MNP reliable mode \N3 Select V.42 auto-reliable mode \N4 Select V.42 reliable mode \Q0 Disables flow control \Q1 Enables XON/XOFF software flow control \Q2 Enables CTS hardware flow control \Q3 Enables CTS/RTS hardware flow control \Tn Set inactivity timer in minutes(n=0-255, default is 0) \V0 Disables protocol result code appended to DCE speed \V1 Enables protocol result code appended to DCE speed \X0 Process XON/XOFF character as flow control character only \X1 Process XON/XOFF character as flow control character and pass through to local DTE or remote modem Notes: The default setting of commands is in bold Italic text format. - 21 - Rev.1.00.2.1.34 TFM-PCIV92A User's Guide _____ Appendix 3 S-Register Summary Register S0* S1* S2* S3 S4 S5 S6* S7* S8* S10* S11* S12* S14* S21* S22* Function Default Range No. of rings to start auto-answer 0 0-255 Ring count 0 0-255 Escape character 43 0-255 Carriage return character 13 0-127 Line feed character 10 0-127 Backspace character 8 0-32,127 Wait before dialing 2 2-65 Wait for carrier 50 1-255 Pause time for dial modifier , 2 0-65 Lost carrier hang up delay 20 1-254 DTMF dialing speed 95 50-150 Escape guard time 50 0-255 Bit-mapped register - 0-255 Bit 0,1,2 Reserved Bit 3 = 0 V0 is selected = 1 V1 is selected Bit 4,5 Reserved Bit 6 = 0 10 PPS pulse dialing(&P0, &P1) = 1 20 PPS pulse dialing(&P2) Bit 7 Reserved Bit-mapped register - 0-255 Bit0,1,2 Reserved Bit 4-3 = 00 &D0 is selected = 01 &D1 is selected = 10 &D2 is selected = 11 &D3 is selected Bit 5 = 0 &C0 is selected = 1 &C1 is selected Bit 6,7 Reserved Bit-mapped register - 0-255 Bit 0,1,2,3 Reserved Bit 6-4 = 000 X0 is selected = 001 Reserved = 010 Reserved = 011 Reserved = 100 X1 is selected - 22 - Units ring ring ASCII ASCII ASCII ASCII second second second 0.1second msec 20 msec - - - Rev.1.00.2.1.34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

TFM-PCIV92A User’s Guide
_________________________________________________________________________________________________________________________
- 21 -
Rev.1.00.2.1.34
n = 14
44000 BPS
n = 15
45333 BPS
n = 16
46666 BPS
n = 17
48000 BPS
n = 18
49333 BPS
n = 19
50666 BPS
n = 20
52000 BPS
n = 21
53333 BPS
-V90?
Reports current V.90 setting
\A0
Set maximum MNP block size to 64 characters
\A1
Set maximum MNP block size to 128 characters
\A2
Set maximum MNP block size to 192 characters
\A3
Set maximum MNP block size to 256 characters
\Bn
Transmit break in n*100ms (n = 0-9)
\G0
Disables XON/XOFF flow control between local and remote modems
\G1
Enables XON/XOFF flow control between local and remote modems
\J0
Disables DTE speed adjust
\J1
Enables DTE speed adjust
\Kn
Set break control (n=0-5, default is 5).
\N0
Select normal mode
\N1
Select normal mode
\N2
Select MNP reliable mode
\N3
Select V.42 auto-reliable mode
\N4
Select V.42 reliable mode
\Q0
Disables flow control
\Q1
Enables XON/XOFF software flow control
\Q2
Enables CTS hardware flow control
\Q3
Enables CTS/RTS hardware flow control
\Tn
Set inactivity timer in minutes(n=0-255, default is 0)
\V0
Disables protocol result code appended to DCE speed
\V1
Enables protocol result code appended to DCE speed
\X0
Process XON/XOFF character as flow control character only
\X1
Process XON/XOFF character as flow control character and pass through to local DTE
or remote modem
Notes:
The default setting of commands is in
bold Italic text
format.
AT
Command prefix
TFM-PCIV92A User’s Guide
_________________________________________________________________________________________________________________________
- 22 -
Rev.1.00.2.1.34
Appendix 3
S-Register Summary
S0*
No. of rings to start auto-answer 0
0-255
ring
S1*
Ring count
0
0-255
ring
S2*
Escape character
43
0-255
ASCII
S3
Carriage return character
13
0-127
ASCII
S4
Line feed character
10
0-127
ASCII
S5
Backspace character
8
0-32,127
ASCII
S6*
Wait before dialing
2
2-65
second
S7*
Wait for carrier
50
1-255
second
S8*
Pause time for dial modifier ,
2
0-65
second
S10*
Lost carrier hang up delay
20
1-254
0.1second
S11*
DTMF dialing speed
95
50-150
msec
S12*
Escape guard time
50
0-255
20 msec
S14*
Bit-mapped register
-
0-255
-
Bit 0,1,2
Reserved
Bit 3
=
0
V0 is selected
=
1
V1 is selected
Bit 4,5
Reserved
Bit 6
=
0
10 PPS pulse dialing(&P0, &P1)
=
1
20 PPS pulse dialing(&P2)
Bit 7
Reserved
S21*
Bit-mapped register
-
0-255
-
Bit0,1,2
Reserved
Bit 4-3
=
00
&D0 is selected
=
01
&D1 is selected
=
10
&D2 is selected
=
11
&D3 is selected
Bit 5
=
0
&C0 is selected
=
1
&C1 is selected
Bit 6,7
Reserved
S22*
Bit-mapped register
-
0-255
-
Bit 0,1,2,3
Reserved
Bit 6-4
=
000
X0 is selected
=
001
Reserved
=
010
Reserved
=
011
Reserved
=
100
X1 is selected
Register
Function
Default
Range
Units