Tripp Lite SU2200RTXLCD2U Owner's Manual for Single-Phase Online Rack UPS with - Page 23

No Bp, Scroll, Select

Page 23 highlights

Operation To Advance to To Change This the Next Screen: Setting: Press SCROLL (v) Press "SELECT" (^) NO BP* SCROLL SELECT Press "SELECT" (^) to SET this value. Press "SCROLL" (v) to advance to the next option. Available values are: Configure via LCD Configuration via EXTERNAL BATTERY CONFIGURATION TOOL software UPS MODEL Factory Battery pack Battery pack Default option 1 option 2 Battery pack option 3 (BP TOOL on LCD display) SU750RTXLCD2U NO BP BP24V15RT2U BP24V28-2U BP24V70RT3U (for any number) SU1000RTXLCD2U NO BP BP24V15RT2U BP24V28-2U BP24V70RT3U (for any number) SU1500RTXLCD2U NO BP BP48V24-2U BP48V60RT3U BP48V60RT3U (for more than 1) SU2200RTXLCD2U NO BP BP48V24-2U BP48V60RT3U BP48V60RT3U (for more than 1) SU3000RTXLCD3U NO BP BP72V15-2U BP72V28RT-3U BP72V28RT3U (for more than 1) Scroll through available values and press SELECT (^) to SET. Factory default = NO BP If you're planning on using your UPS with the additional supported battery pack option listed above as battery pack option 3, EXTERNAL BATTERY CONFIGURATION TOOL software is required. After the EXTERNAL BATTERY CONFIGURATION TOOL software is used, the UPS will display the resulting configuration as "BP TOOL" on the LCD screen. BP TOOL is present as an LCD viewable option, but is itself not selectable (if BP TOOL selection is attempted, the screen will report "READ ONLY. SELECT BY BP TOOL" to confirm the selection has not been accepted). EXTERNAL BATTERY CONFIGURATION TOOL software is a Windows only application and requires a serial cable connection to the UPS in order to run. Visit http://www.tripplite.com/bpconfig to download the software. Battery Pack Models That Require Use of EXTERNAL BATTERY CONFIGURATION TOOL Software: UPS MODEL SU750RTXLCD2U SU1000RTXLCD2U SU1500RTXLCD2U SU2200RTXLCD2U SU3000RTXLCD3U BATTERY PACK MODEL BP24V70RT3U (for any number) BP24V70RT3U (for any number) BP48V60RT3U (for more than 1) BP48V60RT3U (for more than 1) BP72V28RT3U (for more than 1) 13 The FACTORY DEFAULT selection screen will appear. FACTORY DEFAULT gives users a quick and easy way to return the UPS to its' original factory configuration. When selecting YES to FACTORY DEFAULT in the LCD Set-Up screens, the UPS will immediately revert to the original shipping configuration and set of presets. Running a FACTORY DEFAULT will restore these factory settings: OUTPUT VOLTAGE = 120 OUTPUT FREQUENCY = 60Hz BYPASS RANGE = WIDE OVERLOAD ALARM = 105% SHUTDOWN AFTER = DISABLE BATTERY SAVE = DISABLE STANDBY MODE = NO OUTPUT FREQ CONVERTER = DISABLE ECONOMY MODE = DISABLE COLD START = ENABLE BATTERY TEST = MONTHLY EXTERNAL BATT = NO BP FACTORY DEFAULT = YES AUDIBLE ALARM = ENABLE ALARM HISTORY = ALL MESSAGES CLEARED INFORMATION = NO CHANGE To Advance to the Next Screen: Press SCROLL (v) To Change This Setting: Press "SELECT" (^) Note: The UPS must be in Standby Mode to change this setting. Continued on page 24. NO SCROLL SELECT Press "SELECT" (^) to SET this value. Press "SCROLL" (v) to advance to the next option. Available values are: NO, YES Scroll through available values and press SELECT (^) to SET. Factory default = None 23 12-488-93-3156.indb 23 9/12/2012 3:57:11 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

NO BP*
SCROLL
SELECT
Continued on page 24.
 


NO
SCROLL
SELECT
23
Operation
To Change This
Setting:
Press “SELECT” (
^
)
Press “SELECT” (
^
) to SET this value.
Press “SCROLL” (
v
) to advance to the next option.
Available values are:
To Advance to
the Next Screen:
Press SCROLL (
v
)
13
The FACTORY DEFAULT selection screen will appear.
FACTORY DEFAULT gives users a quick and easy way to return the UPS to its’ original
factory configuration. When selecting YES to FACTORY DEFAULT in the LCD Set-Up screens,
the UPS will immediately revert to the original shipping configuration and set of presets.
Running a FACTORY DEFAULT will restore these factory settings:
OUTPUT VOLTAGE = 120
OUTPUT FREQUENCY = 60Hz
BYPASS RANGE = WIDE
OVERLOAD ALARM = 105%
SHUTDOWN AFTER = DISABLE
BATTERY SAVE = DISABLE
STANDBY MODE = NO OUTPUT
FREQ CONVERTER = DISABLE
ECONOMY MODE = DISABLE
COLD START = ENABLE
BATTERY TEST = MONTHLY
EXTERNAL BATT = NO BP
FACTORY DEFAULT = YES
AUDIBLE ALARM = ENABLE
ALARM HISTORY = ALL MESSAGES CLEARED
INFORMATION = NO CHANGE
To Change This
Setting:
Press “SELECT” (
^
)
Press “SELECT” (
^
) to SET this value.
Press “SCROLL” (
v
) to advance to the next option.
Available values are: NO, YES
Scroll through available values and press SELECT
(
^
) to SET.
Factory default = None
To Advance to
the Next Screen:
Press SCROLL (
v
)
Note: The UPS must be
in Standby Mode to
change this setting.
UPS MODEL
Factory
Default
Configure via LCD
Configuration via EXTERNAL BATTERY
CONFIGURATION TOOL software
Battery pack
option 1
Battery pack
option 2
Battery pack option 3
(BP TOOL on LCD display)
SU750RTXLCD2U
NO BP
BP24V15RT2U
BP24V28-2U
BP24V70RT3U (for any number)
SU1000RTXLCD2U
NO BP
BP24V15RT2U
BP24V28-2U
BP24V70RT3U (for any number)
SU1500RTXLCD2U
NO BP
BP48V24-2U
BP48V60RT3U
BP48V60RT3U (for more than 1)
SU2200RTXLCD2U
NO BP
BP48V24-2U
BP48V60RT3U
BP48V60RT3U (for more than 1)
SU3000RTXLCD3U
NO BP
BP72V15-2U
BP72V28RT-3U
BP72V28RT3U (for more than 1)
Scroll through available values and press SELECT (
^
) to SET.
Factory default = NO BP
If you’re planning on using your UPS with the additional supported battery pack option
listed above as battery pack option 3, EXTERNAL BATTERY CONFIGURATION TOOL software
is required. After the EXTERNAL BATTERY CONFIGURATION TOOL software is used, the UPS
will display the resulting configuration as “BP TOOL” on the LCD screen. BP TOOL is present
as an LCD viewable option, but is itself not selectable (if BP TOOL selection is attempted,
the screen will report “READ ONLY. SELECT BY BP TOOL” to confirm the selection has not
been accepted). EXTERNAL BATTERY CONFIGURATION TOOL software is a Windows only
application and requires a serial cable connection to the UPS in order to run.
Visit http://www.tripplite.com/bpconfig to download the software.
Battery Pack Models That Require Use of EXTERNAL BATTERY CONFIGURATION TOOL
Software:
UPS MODEL
BATTERY PACK MODEL
SU750RTXLCD2U
BP24V70RT3U (for any number)
SU1000RTXLCD2U
BP24V70RT3U (for any number)
SU1500RTXLCD2U
BP48V60RT3U (for more than 1)
SU2200RTXLCD2U
BP48V60RT3U (for more than 1)
SU3000RTXLCD3U
BP72V28RT3U (for more than 1)
12-488-93-3156.indb
23
9/12/2012
3:57:11 PM