ViewSonic VTMS2431 User Guide - Page 59

Remote Control Pass-through mode

Page 59 highlights

ENGLISH Other Information 6. Remote Control Pass-through mode When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes packet (followed by "CR") in response to RCU button activation. Note, that in this mode the RCU shall have no effect on the monitor function. For example: "+Volume" will not change the volume in the LCD but only sends "+Volume" code to PC over the RS232 port. RCU Pass-through Command description: Length Total Byte of Message excluding "CR" TV ID Identification for each of TV Command Type Identify command type, "p" (0x70h) : RCU Pass-through Value[1~2] Two bytes ASCII that defines the value CR 0x0D RCU Pass-through Command Format: Reply: (Command Type= "p") Name Length ID Command Value1 Type Byte Count 1 Byte 2 Byte 1 Byte 1 Byte Bytes order 1 2~3 4 5 Value2 1 Byte 6 CR 1 Byte 7 Example1: User press "Menu" Key form RCU to TV-03 and RCU data pass-through to Server, then server will receive "1A". Reply (Hex Format) Name Length ID Command Value1 Value2 CR Type Hex 0x36 0x30 0x70 0x31 0x41 0x0D 0x33 Example2: User press "5" Key form RCU to TV-07 and RCU data pass-through to Server, then server will receive "05". Reply (Hex Format) Name Length ID Command Value1 Value2 CR Type Hex 0x36 0x30 0x70 0x30 0x35 0x0D 0x36 Contact ViewSonic service team at: http://www.ViewSonic.com or call our service team: United States 1-800-688-6688, Canada 1-866-463-4775 ViewSonic 54 VTMS2431

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63

54
ENGLISH
Contact ViewSonic service team at: http://www.ViewSonic.com or call our service team: United States 1-800-688-6688, Canada 1-866-463-4775
ViewSonic
VTMS2431
Other Information
6. Remote Control Pass-through mode
When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send
a three bytes packet (followed by “CR”) in response to RCU button activation. Note, that
in this mode the RCU shall have no effect on the monitor function. For example: “+Volume”
will not change the volume in the LCD but only sends “+Volume” code to PC over the
RS232 port.
RCU Pass-through Command description:
Length
Total Byte of Message excluding “CR”
TV ID
Identification for each of TV
Command Type
Identify command type,
“p” (0x70h) : RCU Pass-through
Value[1~2]
Two bytes ASCII that defines the value
CR
0x0D
RCU Pass-through Command Format:
Reply: (Command Type= “p”)
Name
Length
ID
Command
Type
Value1
Value2
CR
Byte Count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
6
7
Example1: User press “Menu” Key form RCU to TV-03 and RCU data pass-through
to Server, then server will receive “1A”.
Reply (Hex Format)
Name
Length
ID
Command
Type
Value1
Value2
CR
Hex
0x36
0x30
0x33
0x70
0x31
0x41
0x0D
Example2: User press “5” Key form RCU to TV-07 and RCU data pass-through to
Server, then server will receive “05”.
Reply (Hex Format)
Name
Length
ID
Command
Type
Value1
Value2
CR
Hex
0x36
0x30
0x36
0x70
0x30
0x35
0x0D