Viking VDD5360 VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst
Viking VDD5360 Manual
View all Viking VDD5360 manuals
Add to My Manuals
Save this manual to your list of manuals |
Viking VDD5360 manual content summary:
- Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 1
with these Downdraft Ventilators: Models VDD5300, VDD5360, VDD5450, VDD5480 (Purchase Downdraft Ventilator separately.) READ AND SAVE THESE INSTRUCTIONS WARNING part of this appliance unless specifically recommended in this manual. All other servicing should be done by a qualified technician. 6. - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 2
(4) wood screws #10 x .50 (4) blower mount brackets (1) strain relief bushing For use when mounting Flex Blower directly to Downdraft housing. (See Downdraft instruction manual.) (4) MOUNTING BRACKETS attached with 1/4-20 X .50 HEX HEAD SCREWS PLAN THE INSTALLATION If you choose to mount the Flex - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 3
WARRANTY Model VDVI600 DOWNDRAFT WARRANTY ONE YEAR FULL WARRANTY Downdrafts and all of their component parts, limitation may not apply to you. WARRANTY SERVICE To obtain warranty service, contact an authorized Viking Range, LLC service agent, or Viking Range, LLC 111 Front Street, Greenwood, - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 4
les ventilateurs encastrés suivants : Modèles VDD5300, VDD5360, VDD5450, VDD5480 (Ventilateurs encastrés vendus séparément . SI LES FLAMMES NE S'ÉTEIGNENT PAS IMMÉDIATEMENT, QUITTEZ LES LIEUX ET APPELEZ LE SERVICE DES INCENDIES. 2. NE SOULEVEZ JAMAIS UNE CASSEROLE EN FLAMMES - vous pourriez vous brû - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 5
3 po (7,6 cm) de largeur À utiliser pour fixer le ventilateur Flex directement sur le boîtier de la hotte encastrée. (Consulter le manuel d'instruction de la hotte encastrée.) Un sac de pièces contenant : (4) Vis à bois n° 10 x 0,50 (4) Brides de montage de ventilateur (1) Bague antitraction - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 6
garantie tacite, la limitation ci-dessus peut ne pas s'appliquer à votre situation. SERVICE DE GARANTIE Pour bénéficier du service de garantie, contactez une agence de réparation agréée de Viking Range, LLC ou Viking Range, LLC 111 Front Street, Greenwood, Mississippi 38930, (888) 845-4641. Indiquez - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 7
se muestran a continuación. No se pueden utilizar otros modelos de ventiladores de tiro descendente. (Los ventiladores de tiro descendente se venden por separado). Modelos VDD5300, VDD5360, VDD5450, VDD5480 INSTALADOR: Conserve este manual para que lo use el inspector eléctrico y el propietario. 7 - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 8
ventilador flexible directamente en la cubierta de tiro descendente: Retire y deseche la placa del adaptador. Consulte las instrucciones de instalación en el manual del tiro descendente. Si desea montar el ventilador flexible en una ubicación remota (como la parte posterior del gabinete, al lado del - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 9
registro del propietario no es una condición de cobertura de la garantía. Sin embargo, debe devolver la tarjeta de registro del propietario para que Viking Range, LLC pueda comunicarse con usted en caso de que surja alguna situación de seguridad que lo pueda afectar. Esta garantía le otorga derechos - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 10
10 - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 11
11 - Viking VDD5360 | VDVI600 - 600 CFM Interior Power Ventilator - Installation Inst - Page 12
(030518) 12 99045275C
1
Model VDV
I
600
FLEX BLOWER
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1.
Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4.
Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7.
To reduce the risk of fire, use only metal ductwork.
8. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING
a
:
1.
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immedi-
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
a
Based on “Kitchen Firesafety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
3.
To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Clean filters and grease-laden surfaces frequently.
5. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
6.
Please read specification label on product for further information
and requirements.
7.
To reduce the risk of fire and electric shock, install this blower
only with downdraft ventilator models shown below. Other
downdraft
ventilator models cannot be substituted. (Downdraft
ventilators sold separately).
Models
VDD5300, VDD5360, VDD5450, VDD5480
For use with these Downdraft Ventilators:
Models VDD5300, VDD5360, VDD5450, VDD5480
(Purchase Downdraft Ventilator separately.)
!
INSTALLER: Save this manual for Electrical Inspector and Homeowner to use.