Requirements for Designer hoods installed over Professional

Page 42 highlights

Basic specifications - Ventilator kits - Professional and Designer w a ll a nd i s l a nd h o o d s Interior Ventilators In-Line Ventilators Exterior Ventilators d o wndr a f t s Interior Ventilators Exterior Ventilators Model VINV300 VINV600 VINV1200 dIL900 dIL1200 dev900 dev1200 dev1500 vidv500 vedv900 vedv1200 Approximate cfm1 300 600 1,200 900 1,200 900 1,200 1,500 500 900 1,200 recommended duct size See Specifications 3 1/4"x10" 10" round (can transition to 6" round)* maximum duct run2 50 ft. (15.2 m) 75 ft.(22.8 m) 40 ft.(12.1 m) maximum amps See Specifications 4.0 6.0 All 18" high rangehood ventilator kits include rough-in kit, transition to round duct (7" round for VIV600 - all other 10" round), and damper (if applicable). All ventilator kits use 120VAC/60Hz. Proper installation is extremely important to ensure maximum performance from any ventilation product. 1. All CFMs stated based on tests with .1 static pressure; without applying static pressure (some brands consciously do not), CFM could be greatly overstated. 2. Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer. • Straight runs and gradual turns are best; for example, each 90-degree elbow is equal to 5-10 feet (1.52-3.05 m) of straight run. • Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance. • Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used. • Check with a qualified and trained installer or local codes for makeup air requirements, if any. Requirements for Designer hoods installed over Professional cooking products with char-grill feature Designer hoods can be installed over Professional cooking products. However, when choosing a Professional range or rangetop with the gas char-grill feature, the following ventilator kits must be used to ensure proper performance: de s i g ner h o o d s * 30", 33", 36", 39", 42", and 45" wide hoods - Classic Chimney models and Built-in Custom Ventilator Systems as noted below 36" and 42" wide hoods - Tall Traditional models as noted below 48" wide hoods - Tall Traditional models as noted below 48" and 51" wide hoods - Classic Chimney models and Built-in Custom Ventilator Systems as noted below ven t il a t o r ki t (when used over ranges/rangetops with char-grill) 1,200 CFM exterior ventilator kit (DEV1200) 1,200 CFM interior or exterior ventilator kit (VINV1200 or DEV1200) 1,200 CFM interior or exterior ventilator kit (VINV1200 or DEV1200) or 1,500 CFM exterior ventilator kit (DEV1500) 1,200 CFM interior or exterior ventilator kit (VINV1200 or DEV1200) or 1,500 CFM exterior ventilator kit (DEV1500) * Includes the following wall hoods: Classic Chimney, Classic Chimney with Ledge, Classic Chimney Ledgeless, Built-in Custom Ventilation Systems (for wall hoods), Tall Traditional with Ledge, and Tall Traditional Ledgeless. (Slim Traditional wall hoods, Box wall hoods, Classic Chimney island hoods, and Island custom ventilator systems should not be installed over Professional ranges and rangetops with the gas char-­grill feature.) 42

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

42
Designer hoods can be installed over Professional cooking products. However, when choosing a Professional range or rangetop with the
gas char-grill feature, the following ventilator kits must be used to ensure proper performance:
*
Includes the following wall hoods: Classic Chimney, Classic Chimney with Ledge, Classic Chimney Ledgeless, Built-in Custom Ventilation Systems (for wall hoods),
Tall Traditional with Ledge, and Tall Traditional Ledgeless. (Slim Traditional wall hoods, Box wall hoods, Classic Chimney island hoods, and Island Custom Ventilator Systems
should not be installed over Professional ranges and rangetops with the gas char-grill feature.)
DESIGNER HOODS*
VENTILATOR KIT
(when used over ranges/rangetops with char-grill)
30", 33", 36", 39", 42", and 45" wide hoods – Classic Chimney models and
Built-in Custom Ventilator Systems as noted below
36" and 42" wide hoods – Tall Traditional models as noted below
48" wide hoods – Tall Traditional models as noted below
48" and 51" wide hoods – Classic Chimney models and Built-in Custom
Ventilator Systems as noted below
1,200 CFM exterior ventilator kit (DEV1200)
1,200 CFM interior or exterior ventilator kit (VINV1200 or DEV1200)
1,200 CFM interior or exterior ventilator kit (VINV1200 or DEV1200)
or 1,500 CFM exterior ventilator kit (DEV1500)
1,200 CFM interior or exterior ventilator kit (VINV1200 or DEV1200)
or 1,500 CFM exterior ventilator kit (DEV1500)
Requirements for Designer hoods installed over Professional
cooking products with char-grill feature
WALL AND ISLAND HOODS
All 18" high rangehood ventilator kits include rough-in kit, transition to round duct ( 7" round for VIV600 – all other 10" round), and damper (if applicable).
All ventilator kits use 120VAC/60Hz.
Proper installation is extremely important to ensure maximum performance from any ventilation product.
1. All CFMs stated based on tests with .1 static pressure; without applying static pressure (some brands consciously do not), CFM could be greatly overstated.
2. Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer.
• Straight runs and gradual turns are best; for example, each 90-degree elbow is equal to 5-10 feet (1.52-3.05 m) of straight run.
• Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
• Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.
• Check with a qualified and trained installer or local codes for makeup air requirements, if any.
DOWNDRAFTS
Model
Basic specifications – Ventilator kits – Professional and Designer
Interior
Ventilators
Exterior
Ventilators
In-Line
Ventilators
Exterior
Ventilators
Interior
Ventilators
APPROXIMATE CFM
1
RECOMMENDED
DUCT SIZE
MAXIMUM DUCT RUN
2
MAXIMUM AMPS
300
600
1,200
900
1,200
900
1,200
1,500
500
900
1,200
See Specifications
3 1/4"x10" 10" round
(can transition
to 6" round)*
50 ft. (15.2 m)
75 ft.(22.8 m)
40 ft.(12.1 m)
See Specifications
4.0
6.0
VINV600
VINV1200
VINV300
DEV900
DIL1200
DIL900
DEV1200
VIDV500 VEDV900 VEDV1200
DEV1500