Whirlpool CGM2941TQ Installation Instructions - Page 9

A. Individualdryervent, B.Main vent, A. Exhausthood or, B. Wall, C.Maincollectorvent, D. Horizontal - parts lint

Page 9 highlights

Multiple Dryer Venting [] A main vent can be used for venting a group of dryers. Main vent should be sized to remove 200 CFM of air per dryer. Large-capacity lint screens of proper design may be used in the main vent if checked and cleaned frequently. The room where the dryers are located should have make-up air equal to or greater than the CFM of all the dryers in the room. [] Back-draft Damper Kits, Part No. 3391910, are available from your Whirlpool dealer and should be installed in each dryer's vent to prevent exhausted air from returning into the dryers and to keep the exhaust in balance within the main vent. Unobstructed air openings are required. Each vent should enter the main vent at an angle pointing in the direction of the airflow. Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents. The maximum angle of each vent entering the main vent should be no more than 30 °. if an exhaust hood cannot be used: The outside end of the main vent should have a sweep elbow directed downward. If the main vent travels vertically through the roof, rather than through the wall, install a 180° sweep elbow on the end of the vent at least 2 feet (61 cm) above the highest part of the building. The opening wall or roof shall have a diameter 1A" (1.3 cm) larger than the vent diameter. The vent should be centered in the opening. sC E /_'_ ......I...... I _ _t. A. Exhausthood or elbow BC. WMaailnl collectorvent D. Horizontavl ent E. t80 ° sweepelbow E Verticalvent .Roo (61 crn)rain, above air flow _ B -,_-- _ _ highest point of building A. Individualdryervent B.Main vent Keep air openings free of dry cleaning fluid fumes. Fumes create acids which, when drawn through the dryer heating units, can damage dryers and loads being dried. A clean-out cover should be located on the main vent for periodic cleaning of the vent system. Do not install screening or cap over the end of the vent.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Multiple
Dryer
Venting
[]
A main vent can be used for venting a group of dryers. Main
vent should be sized to remove 200 CFM of air per dryer.
Large-capacity
lint screens of proper design may be used in
the main vent if checked
and cleaned frequently. The room
where the dryers are located
should have make-up
air equal
to or greater than the CFM of all the dryers in the room.
[]
Back-draft
Damper Kits, Part No. 3391910,
are available from
your Whirlpool
dealer and should
be installed in each dryer's
vent to prevent exhausted
air from returning into the dryers
and to keep the exhaust
in balance
within the main vent.
Unobstructed
air openings
are required.
Each vent should enter the main vent at an angle pointing
in the
direction of the airflow. Vents entering
from the opposite
side
should be staggered to reduce the exhausted
air from interfering
with the other vents.
The maximum
angle of each vent entering the main vent should
be no more than 30°.
air flow
_
B
-,_--
A. Individualdryervent
B.Main vent
Keep air openings
free of dry cleaning fluid fumes.
Fumes create
acids which,
when drawn through the dryer heating units, can
damage
dryers and loads being dried.
A clean-out
cover should
be located
on the main vent for periodic
cleaning
of the vent system.
if
an exhaust
hood
cannot
be used:
The outside
end of the main vent should have a sweep elbow
directed downward.
If
the main vent travels vertically
through
the
roof, rather than through the wall, install a 180° sweep
elbow on
the end of the vent at least 2 feet (61 cm) above the highest
part
of the building.
The opening
wall or roof shall have a diameter
1A"
(1.3 cm) larger than the vent diameter. The vent should be
centered
in the opening.
s
C
A. Exhausthood or
elbow
B. Wall
C.Maincollectorvent
D. Horizontal
vent
E. t80
°
sweep
elbow
E
/_'_
E
Verticalvent
°
.........
(
.Roo
............
I
I
_
_t.
(61 crn)rain,
above
__
highest
point of building
Do not install screening
or cap over the end of the vent.