Whirlpool GXI6536DXS Use & Care Guide - Page 11

Range Hood Care

Page 11 highlights

RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to the following instructions. Replace grease filters before operating hood. 3. Place charcoal filter into top side of metal filter. 4. Bend spring clips back into place to secure the charcoal filter to the metal filter. Exterior Surfaces: To avoid damage to the exterior surface, do not use steel wool or soap-filled scouring pads. Always wipe dry to avoid water marks. Cleaning Method: ■ Liquid detergent soap and water, or all-purpose cleanser ■ Wipe with damp soft cloth or nonabrasive sponge, then rinse with clean water and wipe dry. Metal Grease Filter 1. Remove each filter by pulling the spring release handle and then pulling down the filter. A A. Spring release handle 5. Replace metal grease filter. See "Metal Grease Filter" in this section. Replacing a Halogen Lamp Turn off the range hood and allow the halogen lamp to cool. To avoid damage or decreasing the life of the new bulb, do not touch bulb with bare fingers. Replace bulb, using tissue or wearing cotton gloves to handle bulb. If new lights do not operate, make sure the lamps are inserted correctly before calling service. 1. Disconnect power. 2. Use a flat-blade screwdriver and gently pry the light cover loose. 2. Wash metal filters as needed in dishwasher or hot detergent solution. 3. Reinstall the filter by making sure the spring release handles are toward the front. Insert aluminum filter into upper track. 4. Push in spring release handle. 5. Push up on metal filter and release handle to latch into place. Non-Vented (recirculating) Installation Filters The charcoal filter is not washable. It should last up to 6 months with normal use. Replace with Charcoal Filter Kit Number W10294730. To replace charcoal filter: 1. Remove metal grease filter from range hood. See "Metal Grease Filter" in this section. 2. Bend spring clips away from metal grease filter. 3. Remove the lamp and replace with a 12-volt, 20-watt maximum, halogen lamp made for a G-4 base. 4. Replace the light cover. 5. Reconnect power. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

11
RANGE HOOD CARE
Cleaning
IMPORTANT:
Clean the hood and grease filters frequently
according to the following instructions. Replace grease filters
before operating hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool or
soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose cleanser
Wipe with damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
Metal Grease Filter
1.
Remove each filter by pulling the spring release handle and
then pulling down the filter.
2.
Wash metal filters as needed in dishwasher or hot detergent
solution.
3.
Reinstall the filter by making sure the spring release handles
are toward the front. Insert aluminum filter into upper track.
4.
Push in spring release handle.
5.
Push up on metal filter and release handle to latch into place.
Non-Vented (recirculating) Installation Filters
The charcoal filter is not washable. It should last up to 6 months
with normal use. Replace with Charcoal Filter Kit Number
W10294730.
To replace charcoal filter:
1.
Remove metal grease filter from range hood. See “Metal
Grease Filter” in this section.
2.
Bend spring clips away from metal grease filter.
3.
Place charcoal filter into top side of metal filter.
4.
Bend spring clips back into place to secure the charcoal filter
to the metal filter.
5.
Replace metal grease filter. See “Metal Grease Filter” in this
section.
Replacing a Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool. To
avoid damage or decreasing the life of the new bulb, do not
touch bulb with bare fingers. Replace bulb, using tissue or
wearing cotton gloves to handle bulb.
If new lights do not operate, make sure the lamps are inserted
correctly before calling service.
1.
Disconnect power.
2.
Use a flat-blade screwdriver and gently pry the light cover
loose.
3.
Remove the lamp and replace with a 12-volt, 20-watt
maximum, halogen lamp made for a G-4 base.
4.
Replace the light cover.