3. Attach a second set of vertical supports (A) and set the vertical height (B). See "Installation Clearances" in the "Location Requirements" section to help determine the desired dimension for vertical height "B." A A B A. Vertical supports B. Vertical height 4. Assemble rubber seals to the front and back flange of the ventilator assembly. 6. Install retainer bracket to both sides and secure with 4 - 4 x 8 mm screws to hold glass canopy to ventilator assembly. A B C A. Retainer bracket B. Glass canopy C. Ventilator assembly 7. Attach the range hood assembly to the upper horizontal support attached to the ceiling using 16 - 4 x 8 mm screws and tighten. A A A. Rubber seal 5. Assemble and center glass canopy to ventilator assembly. B A A. Glass canopy B. Ventilator assembly A. Mounting screws Connect Vent System 1. Install vent system. 2. Push duct over the exhaust outlet. Seal all connections with vent clamps. Non-Vented (recirculating) Installation 1. Attach the air deflector to the upper horizontal support using 4 mounting screws. B A B A. Deflector B. Mounting screws 2. Measure the length of 6" (15.2 cm) duct needed to connect the transition to the deflector. NOTE: Vent should fit up inside the deflector 1" (2.5 cm) minimum. 3. Install vent between the transition and the deflector. NOTE: To make vent installation easier, temporarily remove the deflector from the chimney support bracket and replace after vent section is in place. 4. Seal all connections with vent clamps. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

8
3.
Attach a second set of vertical supports (A) and set the
vertical height (B). See “Installation Clearances” in the
“Location Requirements” section to help determine the
desired dimension for vertical height “B.”
4.
Assemble rubber seals to the front and back flange of the
ventilator assembly.
5.
Assemble and center glass canopy to ventilator assembly.
6.
Install retainer bracket to both sides and secure with 4 - 4 x
8 mm screws to hold glass canopy to ventilator assembly.
7.
Attach the range hood assembly to the upper horizontal
support attached to the ceiling using 16 - 4 x 8 mm screws
and tighten.
Connect Vent System
1.
Install vent system.
2.
Push duct over the exhaust outlet. Seal all connections with
vent clamps.
Non-Vented (recirculating) Installation
1.
Attach the air deflector to the upper horizontal support using
4 mounting screws.
2.
Measure the length of 6" (15.2 cm) duct needed to connect
the transition to the deflector.
NOTE:
Vent should fit up inside the deflector 1" (2.5 cm)
minimum.
3.
Install vent between the transition and the deflector.
NOTE:
To make vent installation easier, temporarily remove
the deflector from the chimney support bracket and replace
after vent section is in place.
4.
Seal all connections with vent clamps.
A. Vertical supports
B. Vertical height
A. Rubber seal
A. Glass canopy
B. Ventilator assembly
B
A
A
A
A
B
A. Retainer bracket
B. Glass canopy
C. Ventilator assembly
A. Mounting screws
A. Deflector
B. Mounting screws
A
B
C
A
B
B
A