A. Wire-mounting plate, B. Grommet, A. Deep cover, B. Front cover, C. Cover box supplied
View all Whirlpool UXD8630DY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
6. Hold the wire-mounting plate and push the grommet out of the wire-mounting plate. A 14. Remove the front cover from the deep cover, place the front cover over the previously mounted cover box, and secure using the 4 screws previously removed. B A. Wire-mounting plate B. Grommet 7. Slide the wire assembly through the slot in the wire-mounting plate to remove it. 8. Place the wire assembly through the opening to the opposite side of the vent box. A 9. Reassemble the wire assembly and grommet to the wire-mounting plate. 10. Install the wire mounting plate to the vent box using the 4 screws previously removed. B B C A. Deep cover B. Front cover C. Cover box (supplied) 11. Place the blower motor box assembly with the keyhole slots over the 2 shoulder screws on the rear of the vent box and reconnect the wire connection to the blower motor. 15. Go to the "Complete Installation" section. 12. Mount the blower motor box to the vent box and secure using the 6 screws previously removed. 13. Mount the 43/4" (12.0 cm) cover box (supplied) to the front of the vent box. Place the keyhole slots over the 2 shoulder screws, align the mounting holes, and secure the cover box to vent box using the 6 screws previously removed from the ¼" (6.4 mm) deep cover. 13