Whirlpool UXL5430BSS Installation Guide - Page 7
Electrical Requirements
View all Whirlpool UXL5430BSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Electrical Requirements WARNING ■ To minimize possible shock hazard, the cord must be plugged into a mating, 3 prong, grounding-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician. Electrical Shock Hazard Plug into a grounded 3 prong outlet. ■ The grounded 3 prong outlet is to be located inside the cabinet above the range hood at a maximum distance of 33 85.0 cm) from where the power cord exits the hood. The grounded 3 prong outlet must be accessible after installation of the range hood. See illustration. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. 33 85 cm) Failure to follow these instructions can result in death, fire, or electrical shock. IMPORTANT: The range hood must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 (latest edition) or Canadian Electrical Code, CSA C22.1 No. 0-M91 (latest edition). If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate. A copy of the above code standards can be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575 ■ A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range hood be provided. ■ This range hood is equipped with a power supply cord having a 3 prong grounding plug. GROUNDING INSTRUCTIONS ■ For a grounded, cord-connected range hood: This range hood must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This range hood is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING: Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the range hood is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the range hood. SAVE THESE INSTRUCTIONS 7