FOR SERVICE TECHNICIAN'S USE ONLY INSTALL DIAGNOSTICS NOTE: The Service Diagnostic mode must be activated before entering Install Diagnostics; see procedure on page 4. NOTE: If, at any point, the user presses the POWER button or opens the door during Install Diagnostics, the dryer exits to standby mode. NOTE: Door must be closed to perform test. Dryer must be cool before test to run correctly. Active Fault Code Display in Install Diagnostics If the display begins flashing while in Install Diagnostics, it is displaying an active fault code. Active fault codes are codes that are currently detected. Only one active fault code can be displayed at a time. Entry Procedure To enter Install Diagnostics, press and release the 2nd button used to activate the Service Diagnostic mode. All LEDs turn off and the START button begins to flash. WATER-ONLY TEST: Press and hold the START button for 5 seconds to run only the water system test. PERFORM ALL TESTS: Press and release the START button to run ALL tests indicated in the chart below. Exit Procedure When test is complete, press the POWER button to exit Install Diagnostics and return to standby mode. INSTALL DIAGNOSTICS STEP TEST TEST DRYER FUNCTION COMPONENT NOTES 1 L Dryer starts L2 detection algorithm. Motor On Display shows "- - -" or "- -" until voltage is available at UI. 1 • If Electric: Displays L2 level (range 2 L L2 detection complete. 2 Motor On 0 to 200). • If Gas: Displays "9as" or "9s" for gas D since L2 does not exist. & E 3 T Dryer starts L1 detection algorithm. Motor On L E Airflow detection starts at this step. Heater On L2 (electric), "9as" or "9s" (gas) continues to be displayed. 4 1 C T t L1 detection complete. CCU calculates L1 to L2. Motor On Once L1 is calculated, L1 to L2 is Heater On/Off immediately calculated in the CCU. o • L1 voltage should be 120 VAC ± 10%. 5 A I R L 2 Press the START button to cycle through L1, L2, and L1 to L2. Motor On Heater On/Off • L2 voltage should be 120 VAC ± 10%, "9as" or "9s" if gas dryer. • L1 to L2 voltage should be 240* VAC F ± 10%, "9as" or "9s" if gas dryer. L O 6 W Airflow test near completion. Motor On The display will count down the final 15 Heater On/Off seconds of the AirFlow detection routine. When the airflow routine is complete, the seven-segment display will show 7 Airflow detection complete. Motor On Heater Off airflow result (0=BAD, 1=GOOD, 2=INVALID). Also, Dryness Level will display results (Less=Bad, More=Good, Nothing=Invalid). 8 W A T 9 E R Press the START button to begin water system test. *Water Valve On Display shows "h28" or "-s" when *Drum Light On running. Steam test running. LED drum light *Water Valve On Water and LED drum light are actuated and water turn on. *Drum Light On for 30 seconds. NOTE: At any time during the test, press and hold the START button for 5 seconds to jump to the water system test. Voltages are displayed in "hex" code. Please refer to the table on page 29 for decoding. Electric dryer performance is optimized for 2-phase, 240 VAC service. If complaint is made regarding electric dryer performance and the L1 to L2 voltage is ~208 VAC, dryer may be connected to a 3-phase service with reduced wattage that will decrease dryer performance. * If equipped. DO NOT REMOVE OR DESTROY PAGE 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

PAGE 7
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DES
TROY
INSTALL DIAGNOSTICS
NOTE:
The Service Diagnostic mode must be
activated before entering Install Diagnostics;
see procedure on page 4.
NOTE:
If, at any point, the user presses the
POWER
button or opens the door during Install
Diagnostics, the dryer exits to standby mode.
NOTE:
Door must be closed to perform test.
Dryer must be cool before test to run correctly.
Active Fault Code Display
in Install Diagnostics
If the display begins flashing while in Install
Diagnostics, it is displaying an active fault
code. Active fault codes are codes that are
currently detected. Only one active fault code
can be displayed at a time.
Entry Procedure
To enter Install Diagnostics, press and release
the
2nd
button used to activate the Service
Diagnostic mode. All LEDs turn off and the
START button begins to flash.
WATER-ONLY TEST:
Press and
hold
the
START
button for 5 seconds to run only the water
system test.
PERFORM ALL TESTS:
Press and
release
the
START
button to run ALL tests indicated in the
chart below.
Exit Procedure
When test is complete, press the
POWER
button to exit Install Diagnostics and return
to standby mode.
STEP
TEST
TEST
DRYER FUNCTION
COMPONENT
NOTES
1
Dryer starts L2 detection algorithm.
Motor On
Display shows “- - -” or “- -” until voltage
is available at UI.
2
L2 detection complete.
Motor On
• If Electric: Displays L2 level (range
0 to 200).
• If Gas: Displays “
9as
” or “
9s
” for gas
since L2 does not exist.
3
Dryer starts L1 detection algorithm.
Airflow detection starts at this step.
Motor On
Heater On
L2 (electric), “
9as
” or “
9s
” (gas)
continues to be displayed.
4
L1 detection complete.
CCU calculates L1 to L2.
Motor On
Heater On/Off
Once L1 is calculated, L1 to L2 is
immediately calculated in the CCU.
5
Press the START button to cycle
through L1, L2, and L1 to L2.
Motor On
Heater On/Off
• L1 voltage should be 120 VAC ± 10%.
• L2 voltage should be 120 VAC ± 10%,
9as
” or “
9s
” if gas dryer.
• L1 to L2 voltage should be 240* VAC
± 10%, “
9as
” or “
9s
” if gas dryer.
6
Airflow test near completion.
Motor On
Heater On/Off
The display will count down the final 15
seconds of the AirFlow detection routine.
7
Airflow detection complete.
Motor On
Heater Off
When the airflow routine is complete,
the seven-segment display will show
airflow result (0=BAD, 1=GOOD,
2=INVALID). Also, Dryness Level will
display results (Less=Bad, More=Good,
Nothing=Invalid).
8
Press the START button to begin
water system test.
*Water Valve On
*Drum Light On
Display shows “
h28
” or “
–s
” when
running.
9
Steam test running. LED drum light
and water turn on.
*Water Valve On
*Drum Light On
Water and LED drum light are actuated
for 30 seconds.
INSTALL DIAGNOSTICS
L
1
L
2
&
L
1
t
o
L
2
D
E
T
E
C
T
A
I
R
F
L
O
W
W
A
T
E
R
NOTE:
At any time during the test, press and hold the START button for 5 seconds to jump to the water system test.
Voltages are displayed in “hex” code. Please refer to the table on page 29 for decoding. Electric dryer performance is optimized for 2-phase,
240 VAC service. If complaint is made regarding electric dryer performance and the L1 to L2 voltage is ~208 VAC, dryer may be connected
to a 3-phase service with reduced wattage that will decrease dryer performance.
* If equipped.