Whirlpool WED9150WW Installation Instructions - Page 5
Spacing for recessed area or closet installation, Closet installation dryer only, Cabinet - electric dryer
UPC - 883049188188
View all Whirlpool WED9150WW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Door open view: 481/8" (1238 mm) 471/8" (1197 mm) ■■ Additional spacing should be considered on all sides of the dryer to reduce noise transfer. ■■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilitation openings are acceptable. ■■ Companion appliance spacing should also be considered. Closet installation (dryer only): 34" recommended (864 mm) 18" min. (457 mm) 3" (76 mm) 48 in.2 (310 cm2) Back view: Electric 61/4" (159 mm) 4" (102 mm) 3" (76 mm) 24 in.2 (155 cm2) 1" (25 mm) 1" (25 mm) Cabinet installation (dryer only): 281/8" (715 mm) 31/2" (89 mm) 7" (178 mm) 18" (460 mm) 14" (358 mm) NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See "Venting Requirements." IMPORTANT: Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below 45° F (7° C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times. Spacing for recessed area or closet installation All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance on sides and rear. ■■ Additional spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, door, and floor moldings. 4" (102 mm) 1" (25 mm) 1" (25 mm) 5