Page 7 highlights

INSTALL LEVELING LEGS ELECTRICAL INSTALLATION For power supply cord installations: 1. Prepare dryer for leveling legs To avoid damaging floor, place a large flat piece of cardboard from dryer carton under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard. 2. Screw in leveling legs Dmdmiiaaaarmmrkkiooinnnnggdd Before you start: disconnect power. 1. Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R). Go to "Power Supply Cord Connection." Power supply cord 3-wire receptacle (NEMA Type 10-30R). Go to "Power Supply Cord Connection." Examine leveling legs and locate diamond marking. Screw legs into leg holes by hand - use a wrench to finish turning legs until diamond marking is no longer visible. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent. 4-wire direct connection: Go to "Direct Wire Connection." 3-wire direct connection: Go to "Direct Wire Connection." NOTE: If local codes do not permit connection of a cabinet-ground conductor to neutral wire, go to "Optional 3-wire connection." This connection may be used with either a power supply cord or a direct wire connection. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

7
INSTALL LEVELING LEGS
To avoid damaging floor, place a large flat piece of cardboard
from dryer carton under entire back edge of dryer. Firmly
grasp dryer body (not console panel) and gently lay dryer
down on cardboard.
Examine leveling legs and locate diamond marking. Screw
legs into leg holes by hand – use a wrench to finish turning
legs until diamond marking is no longer visible.
Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
1.
Prepare dryer for leveling legs
2.
Screw in leveling legs
ELECTRICAL INSTALLATION
For power supply cord installations:
1.
Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R).
Go to “Power Supply Cord Connection.”
3-wire direct connection:
Go to “Direct Wire Connection.”
4-wire direct connection:
Go to “Direct Wire Connection.”
Power supply cord 3-wire receptacle
(NEMA Type 10-30R).
Go to “Power Supply Cord Connection.”
NOTE:
If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to “Optional
3-wire connection.” This connection may be used with
either a power supply cord or a direct wire connection.
Before you start: disconnect power.
Diamond
marking